Technical information
Installing the Console
The Vista console must be installed in a location that allows adequate
ventilation. There should be at least 150mm of free space around the rear
and sides of the console when in use. Failure to allow adequate ventilation
may result in the console shutting down.
An external uninterruptible power supply can be connected if mains
blackouts are anticipated.
Service & Maintenance
With care the Vista console will require little or no maintenance.
If the front panel requires cleaning, wipe with a mild detergent on a damp
soft cloth.
DO NOT spray liquids onto the front panel.
DO NOT use solvents for cleaning the front panel.
Warning: Do not allow the entry of liquids of any sort into the console
chassis.
Specifications
Parameter
M1
S1
S3
Power Source USB powered
Mains
Mains
Supply
Voltage
5VDC
100-240VAC
+/- 10%
100-240VAC
+/- 10%
Supply
Frequency
N/A
50-60Hz
50-60Hz
Power
Consumption
2.5W
maximum
15W
maximum
25W
maximum
Power
Connector
USB Type B
IEC 3-pin
IEC 3-pin
Ingress
Protection
IP20
IP20
IP20
Ambient
Operating
Temperature
0C Minimum
40C Maximum
0C Minimum
40C Maximum
0C Minimum
40C Maximum
Cooling
Convection
Convection
Convection
Size
249(W) x 62
(H) x 284 (D
540(W) x 72
(H) x 337 (D)
642(W) x 140
(H) x 530 (D)
Weight
Net/shipping
2kg / 3kg
5kg / 7kg
15kg / 20kg