3.2
Connecting loads
See section 8.1 for details of load pin connections. Export models may differ from
these configurations. Connections should be made with the supply switched off.
RACK MOUNTED:
The HP12-TR / HP12-SC output options are:
•
Twelve Clipsal 415P 10 amp three pin sockets
•
Two 19 pin Socapex sockets
•
Four 19 pin Socapex sockets (series-wired)
•
Three 10 pin Wieland sockets
•
Rear DIN-rail mounted terminal blocks
WALL MOUNTED:
The HP12-WMTR / HP12-WMSC output options are:
•
Twelve Clipsal 415P 10 amp three pin sockets
•
Wieland 3-pin sockets
•
Internal DIN-rail mounted terminal blocks
Export models may differ from these configurations.
3.3
Connecting DMX-512 input
The dimmer input signal should conform to the USITT DMX-512 (1990)
specification. The green
DMX IN
LED indicates the presence of DMX signals. See
section 8.2 for connector wiring details.
RACK MOUNTED:
The DMX input to the HP12-TR / HP12-SC dimmers connects to the DMX IN socket
on the front panel. The DMX signal may be daisy-chained to the next dimmer via the
LOOP
socket.
WALL MOUNTED:
The DMX input to the HP12-WMTR / HP12-WMSC dimmers connects to a circuit
card using a labelled screw terminal block. The DMX “thru” signal may be daisy-
chained to the next dimmer via the
LOOP