Attach all (14) shutter clips with a rivet gun using (14) 3/16” rivets and
(14) 3/16” backup washers. Review the illustrations below for placement
and assembly.
Fan
Flange
Shutter
Clip
Rivet
Backup Washer
Rivet
Backup Washer
Fan
Flange
Shutter
Clip
4
5
From the inside of your structure, rotate the fan housing until the motor is
located in the lower right corner. Insert fan housing into the finished
opening and secure to structure using suitable fasteners and washers (not
included).
Interior
of structure
Exterior
of structure
ALL ELECTRICAL WORK SHOULD BE
COMPLETED BY QUALIFIED PERSONNEL AND
MEET NATIONAL, REGIONAL AND LOCAL CODES
Airflow
Airflow
Airflow
Airflow
Swivel top and side shutter clips open. Set bottom shutter flange between
housing flange and bottom shutter clips. Secure shutter by swiveling top
and side shutter clips over shutter flange.
7
PROVIDING POWER TO FAN
• Wiring should only be performed by a trained electrician to prevent
injury or death.
• Install manual disconnect switch inside building adjacent to fan.
• Route wire to motor with drip loop and secure.
Drip loop will drain accumulated moisture away from the motor.
• Configure internal wires to match supply voltage and wire according
to motor nameplate. Test to verify correct rotation.
• Only permit power to unit when guard and motor’s cover
plate is properly installed to prevent injury.