Jamestronic CHGR801 Quick Setup Manual Download Page 1

Jamestronic CHGR801

Li-ion rechargeable battery charger and analyzer

Quick Setup Manual

SETUP

1.

Before start, you need to prepare following :

1.1  Connect 3 push buttons to J5 using the 4-wire connector provided.

1.2 Prepare battery holder (NOT provided) for 2 cells with independent channel. Each channel MUST be 
electrical isolated from the each other. 

2.

Before turn on the power, connect above items as following diagram. 

Thermistor *

1

2

3

4

Current

Mode

Start/

Display

Push 
buttons 
X3

Normal 
OFF

+

+

-

-

CH1

CH2

BLACK

BLACK

AC 100-240V

AC to DC 

Power Supply

Output 6V, >=2A

center pin 
POSITIVE

*    If the thermistor is not connected, the temperature shown will be <0°C and <32°F. This will not 

affect the normal operation, but lose the thermal shutdown protection.

0807 Ver701

P 1 of 2

Heat sink for Q1-4 must be installed during 
operation. Overheat will damage the devices !

Reviews: