![Jamestronic CHGR801 Quick Setup Manual Download Page 1](http://html1.mh-extra.com/html/jamestronic/chgr801/chgr801_quick-setup-manual_3282481001.webp)
Jamestronic CHGR801
Li-ion rechargeable battery charger and analyzer
Quick Setup Manual
SETUP
1.
Before start, you need to prepare following :
1.1 Connect 3 push buttons to J5 using the 4-wire connector provided.
1.2 Prepare battery holder (NOT provided) for 2 cells with independent channel. Each channel MUST be
electrical isolated from the each other.
2.
Before turn on the power, connect above items as following diagram.
Thermistor *
1
2
3
4
Current
Mode
Start/
Display
Push
buttons
X3
Normal
OFF
+
+
-
-
CH1
CH2
BLACK
BLACK
AC 100-240V
AC to DC
Power Supply
Output 6V, >=2A
center pin
POSITIVE
* If the thermistor is not connected, the temperature shown will be <0°C and <32°F. This will not
affect the normal operation, but lose the thermal shutdown protection.
0807 Ver701
P 1 of 2
Heat sink for Q1-4 must be installed during
operation. Overheat will damage the devices !