The outputs can be configured for several types of action. This configuration is made with sections “c” and “d” of the DIP
switch, SW1. The available choices are as follows:
SW1-c SW1-d Operation
Off Off Momentary
On
Off
Toggle
On On Definite
Off
On
this state is not defined and should not be used
Momentary
action will activate the outputs while the code is being received (while the remote button is being pressed) and
deactivate them when the code is no longer being received.
Toggle
action will alternate states of the outputs each time the code is received.
Definite
action involves Channel 1 only. Channel 2 is not used and remains in the off or deactivated state. The channel 1
output is activated when the first (Ch 1) code is transmitted. It remains activated when that transmission ceases and
additional transmissions of that, Ch 1 code will not change the output state. The channel 1 output is deactivated when the
second (Ch 2) code is transmitted. It then remains deactivated when that code transmission ceases and additional
transmissions of the second (Ch 2) code will not change the output state. Thus, one code only activates the output and the
other code only deactivates it.