Version: 3.1.0
39
e.
After the sensor is installed and powered on, it is recommended to warm up for one hour before
operating.
f.
When using the sensor, pay attention to the mass of the device mounted on it, which should be within
the payload range of the robot.
g.
If you have any doubts or if any faults occur during use, please do not attempt to operate the product.
Instead, contact us directly.
2.1.5.7 Reference Tightening Torques for Sensor Mounting Bolts
Reference tightening torques for type VI sensor mounting bolts are as follows:
Table 2-13 Reference Tightening Torques for Type VI Sensor Mounting Bolts
Metric
Reference Tightening
Torque (Nm)
M2
0.4
M3
2.0
M4
4.0
M5
8.0
M6
13.0
M8
35.0
Summary of Contents for Zu Series
Page 1: ...JAKA ROBOTICS Force Control Products JAKA Se and JAKA Sp...
Page 3: ......
Page 4: ......
Page 17: ...Version 3 1 0 13 M3 2 0 M4 4 0 M5 8 0 M6 13 0 M8 35 0...
Page 41: ...Version 3 1 0 37 Figure 2 36 Installation and Dimensions of the Force Sensor Indicator light...
Page 61: ...Version 3 1 0 57 Figure 3 8 Force Display Interface of the App...
Page 75: ...Version 3 1 0 71 Figure 3 19 Force Display Interface of the App...
Page 79: ...Version 3 1 0 75 Figure 3 21 Collision Detection Function Settings of JAKA Zu Sp...