SW-2001Q-CL
19
6.3. Scan rate and exposure time range
6.3.1 Minimum cycle time of external trigger
Mode
Minimum trigger cycle
No-Shutter
C1+
52.5μs
Shutter-Select
C1+53.75
μs
PWC
Ex C2
C1 =0.1μs; C2=
54.2
μs
6.3.2 Minimum trigger pulse width.
Mode
Via Camera Link
Via Hirose 12-pin
No-Shutter
500ns
5 µs
Shutter-Select
500ns
5 µs
PWC
1.2
μs
50
μs
6.3.3 Compatibility of trigger modes and functions
Mode
Functions
Trigger
Binning Pixel gain
& black
correction
Shading
correction
One-Push WB
Gain &
black
level ctr.
Trigger
interval
variable
(Accumu.
variable)
Program
exposure
time
Gain Shutter
No-Shutter
Internal
Yes
Yes
Yes
Yes
No
Yes
Yes(*1)
No
External
Yes
Yes
Yes
Yes
No
Yes
Yes(*1)
No
Shutter-Select
Internal
Yes
Yes
Yes
Yes
Yes
Yes
Yes(*2)
Yes
External
Yes
Yes
Yes
Yes
Yes
Yes
Yes(*2)
Yes
PWC
External
Yes
Yes
Yes
Yes
No
Yes
No
No
*1: The accumulation period is equal to the trigger interval.
*2: The accumulation period is the setting value for accumulation but the longest period is the
trigger interval.
6.3.4 Trigger modes and auto white balance modes matrix table
Trigger
Control
Manual
One push
gain
One push
shutter
No-Shutter
Internal
Only gain
yes
No
External
Only gain
yes
No
Shutter Select
Internal
yes
yes
yes
External
yes
yes
yes
PWC
Internal
Only gain
yes
No