SP-5000M-USB / SP-5000C-USB
- 22 -
5.5.10 Pulse Generator Inverter
Clear Source Signal can have polarity inverted.
5.5.11 Pulse Generator Setting Parameters
Table15. Pulse Generator setting parameters
Display Name
Value
Clock Pre-scaler
1 to 4096
Pulse Generator Clock (MHz)
[Pixel Generator Tick Frequency: 72MHz]÷[Clock Pre-scaler]
Pulse Generator Selector
- Pulse Generator 0
- Pulse Generator 1
- Pulse Generator Length
1 to 1048575
- Pulse Generator Length (ms)
(
[Clock Source]÷[Clock Pre-scaler]
)
-1
x [Pulse Generator Length]
- Pulse Generator Frequency (Hz)
[
Pulse Generator Length (ms)
]
-1
- Pulse Generator Start Point
0 to 1048574
- Pulse Generator Start Point (ms)
(
[Clock Source]÷[Clock Pre-scaler]
)
-1
x [Pulse Generator Start Point]
- Pulse Generator End Point
1 to 1048575
- Pulse Generator End Point (ms)
(
[Clock Source]÷[Clock Pre-scaler]
)
-1
x [Pulse Generator End Point]
- Pulse Generator pulse-width (ms)
[ Pulse Generator End Point (ms)]
-
[ Pulse Generator Start Point (ms)]
- Pulse Generator Repeat Count
0 to 255
- Pulse Generator Clear Activation
Clear Mode for the Pulse Generators
- Off
- High Level
- Low level
- Rising Edge
- Falling Edge
- Pulse Generator Clear Sync Mode
- Async mode
- Sync mode
- Pulse Generator Clear Source
- Low
- High
- Frame Trigger Wait
- Frame Active
- Exposure Active
- Fval
- Lval
- PulseGenerator0
- PulseGenerator1
- TTL_In1
- OPT In
- NAND0 Out
- NAND1 Out
- Line 10 - TTL 2 In
- Line 11 - LVDS 1 In
- Pulse Generator Inverter(Polarity)
Pulse Generator Clear Inverter
- False
- True
Note:
1. If
Pulse Generator Repeat
Count is set to “0”, the pulse generator works in Free Running mode.