SP-5000M-PMCL / SP-5000C-PMCL
- 49 -
7.3.4 TriggerActivation
This command can select how to activate the trigger.
Rising edge:
At the rising edge of the pulse, the trigger is activated.
Falling edge:
At the falling edge of the pulse, the trigger is activated.
Level High:
During the high level of trigger, the accumulation is activated
Level Low:
During the low level of trigger, the accumulation is activated
If Exposure Mode is set to Trigger Width, Level High or Level Low must be used.
Table - 37
Trigger Activation
7.3.5 Triggeroverlap
This function defines whether or not a trigger pulse can be accepted while data is being read
out.
OFF
:
The trigger pulse is not accepted during CMOS readout.
Read Out
:
The trigger pulse can be accepted during CMOS readout.
7.4. Normal continuous operation (Timed Exposure Mode/Trigger Mode OFF)
This is used for applications which do not require triggering. In this mode, the video signal for
the auto-iris lens is available.
For the video timing, refer to chapter 6.3.
Table – 38 Minimum interval (1X8–1Y)
Trigger Mode
Readout Mode
Time (Min. trigger
period )
Timed Exposure Mode
Trigger Mode OFF
(Note
1
)
Full
30.9 ms
AOI Center 2/3
21.5 ms
AOI Center 1/2
15.5 ms
AOI Center 1/4
7.7 ms
AOI Center 1/8
3.9 ms
V Binning ON (Full) (Note2)
15.5 ms
Note 1
:
Readout setting in Trigger Overlap is not available
Note 2: SP-5000M-PMCL only
7.5. Timed mode (EPS operation)
This mode captures image(s) with a preset exposure time by using the external trigger. An
additional setting determines if the trigger pulse can be accepted during the exposure period.
Primary settings to use this mode
Acquisition Mode = Single frame, Multi-frame or Continuous
Trigger Mode = ON
Exposure Mode = Timed
Trigger Activation Setting
Exposure Mode
Rising Edge
Falling Edge
Level High
Level Low
Timed
○
○
×
×
Trigger width
×
×
○
○
Timed PIV
○
○
×
×
Timed RCT
○
○
×
×