RM-67X Series
50
Appendix
8.3.1
AEC Mode
Function
Command String
Camera Response
Set AEC Mode
:AEC=[D]<cr>
:o<cr>
Set the Auto Exposure Control mode. [D] is the mode
parameter.
0 = Manual.
1 = Auto.
User access to control of the AEC feature is determined by the
SB2 setting. If “AEC=: is received, but SB2=0, the command has
no effect but does not return an error code.
Note: Setting AEC to auto will force the AGC mode (AMD) to
manual.
Get AEC Mode
:AEC?<cr>
:oAEC[D]<cr>
Enquire current AEC Mode. [D] is the current mode value.
0 = Manual.
1 = Auto.
User access to control of the AEC feature is determined by the
SB2 setting. The “AEC=?” command returns the current value
regardless of the SB2 value.
8.3.2
AFE Register Address
Function
Command String
Camera Response
Set AFE Register Address
:AFA=[DDD]<cr>
:o<cr>
Set the AFE register address where subsequent AFE writes
(AFW) will place the value written. [DDD] is the address value
with a range of 0-255.
Get AFE Register Address
:AFA?<cr>
:oAFA[DDD]<cr>
Enquire the current AFE register dddress. [DDD] is the address
value with a range of 0-255.
8.3.3
AFE Write
Function
Command String
Camera Response
Write a value to AFE Register
:AFW=[DDDD]<cr>
:o<cr>
Writes a value to an AFE register at the address previously
specified by the AFA command. [DDD] is the address value with
a range of 0-16,777,215.
Summary of Contents for RM-670
Page 2: ......
Page 10: ...RM 67X Series x List of Tables List of Tables Table 1 RM 67X Product Specifications Table 43 ...
Page 13: ...Hardware Introduction 13 RM 67X Series Figure 1 RM 67X System Configuration ...
Page 17: ...Hardware Installation 17 RM 67X Series Figure 5 15P 02 9P FULL Cable ...
Page 40: ...RM 67X Series 40 Functional Options ...
Page 80: ...RM 67X Series 80 Appendix ...
Page 81: ......