LQ-050CL
10
Connector 2 ( Used only for 4 x 10 Bit output)
Pin No
In/Out
Name
Note
1,14
Shield
GND
2(-),15(+)
O
TxOUT0
Data out
3(-),16(+)
O
TxOUT1
4(-),17(+)
O
TxOUT2
5(-),18(+)
O
TxClk
Clock for CL
6(-),19(+)
O
TxOUT3
Data out
7(+),20(-)
N.C
8(-),21(+)
N.C
9(-),22(+)
N.C
10(+),23(-)
N.C
11,24
N.C
12,25
N.C
13,26
Shield
GND
Note: Applicable cable
No.
Manufacturer Type
Note
Camera side 3M
10226-1A10PL
Cable Ass7y
3M
14B26-SZLB-xxx-0LC Standard
1) xxx shows the length of the cable. Applicable length is 0.5m to 10m.
2) Cables which are do not comply with CameraLink
TM
Specifications,
14B26-SZ3B-xxx-03C(small diameter cable) and 14SZ3B-xxx-04C(High-Flex cable)
can be used but the capable length is limited.
5.3. Input and output circuits
5.3.1 Trigger input
The External Trigger signal can be
applied either through the Camera
Link connector or at pin 10 of the
12-pin Hirose connector. The
command to change this setting is TI
(Trigger Input). TI=0 for Camera Link
connector (factory default) and TI=1
for 12-pin Hirose connector. The
input via the 12-pin Hirose connector
is AC coupled.
To allow long pulses, which may be
required when using the Pulse Width
Control (PWC) trigger mode, the
input
circuit is designed as a flip-flop circuit. The leading and trailing edges of the trigger pulse
activate the circuit.
The trigger input polarity can be changed by the command TP. At the 12-pin Hirose
connector the External Trigger input is 4V ± 2V (TTL). It can be changed to 75 ohm
termination by a DIP switch setting (SW 1).
Fig. 6 Trigger input (12-pin Hirose)
Summary of Contents for LQ-050CL