LUT (Lookup Table)
The LUT function is used to generate a non-linear mapping between signal values captured on the
sensor and those that are output from the camera.
You can specify the output curve using 257 setting points (indexes).
To Use the LUT Function
Configure the settings as follows.
Item
Setting Value /
Selectable Range
Description
LUTMode
LUT
Use LUT.
LUTSelector*
Red, Green, Blue
Select the LUT channel to control.
LUTIndex
0
~
256
Select the LUT index to configure. Indexes represent
the possible pixel values captured on the sensor,
from the lowest value (Index 0) to the highest (Index
256). For example, Index 0 represents a full black
pixel and Index 256 represents a full white pixel.
LUTValue
0
~
4095
Set the LUT output value for the selected index.
*) Color model only.
LUT Value
LUT values range from 0 at the lowest to 4095 at the highest. Linear interpolation is used to
calculate LUT values between the index points.