User Manual (Ver.1.4) - Main Functions
GOX-5105MC-CXP | GOX-8105MC-CXP | GOX-12405MC-CXP | GOX-16205MC-CXP | GOX-20405MC-CXP | GOX-24505MC-CXP
- 37 -
GPIO (Digital Input/Output Settings)
Related Setting Items:
The camera can input/output the following signals to and from external input/output connectors.
External Output
Line2 : Opt Out
DC IN / TRIG IN Connector (6-pin round)
Internal Output
Line5 : Opt In
DC IN / TRIG IN Connector (6-pin round)
These signals can be used as triggers and other necessary signals within the camera or as signals
output from the camera to the system, such as those used for lighting equipment control.
Use the
to set the digital input/output. Select input or output in LineSelector, you can
check LineMode, LineFormat, and set LineInverter. You can also check the status of each digital I/O
as shown in the table below with LineStatusAll.
LineSelector
LineMode
LineFormat
LineInverter
LineStatusAll
Line2 (Opt Output1)
Output
OptCoupled
True/False
bit1
DC IN / TRG
IN connector
Line5 (Opt In 2)
Input
OptCoupled
False (fixed)
bit4
DC IN / TRG
IN connector
Line7 (Cxp In)
Input
InternalSignal
False (fixed)
bit6
Nand0In1
Input
InternalSignal
True/False
Nand0In2
Input
InternalSignal
True/False
Nand1In1
Input
InternalSignal
True/False
Nand1In2
Input
InternalSignal
True/False
TimestampReset
Internal
Connection
InternalSignal
False (fixed)
For digital output, set the output source signal using LineSource. Set the source signal in the same
way for NAND Logic (Nand0In1, Nand0In2, Nand1In1, NandIn2) and TimestampReset.