Step 5: Adjusting the Image Quality
Adjusting the Gain
Adjust the sensitivity via the analog gain (i.e., master gain).
For details on gain control, see “Gain Control” (page 32) in the “Main Functions” section.
■
Manual adjustment
1
Expand [Analog Control], and set [Gain Auto] to [Off].
([Off] is the default setting.)
2
Configure the gain.
u
Expand [Analog Control], and select the gain you want to configure in [Gain Selector].
•
For the GO-5101M-PGE, only [Analog All] (master gain) can be configured.
•
For the GO-5101C-PGE, [Analog All] (master gain), [Digital Red] (digital R gain), and [Digital
Blue] (digital B gain) can be configured individually.
v
Configure the gain value in [Gain].
•
[Digital All] (master gain) can be set to a value from x1 to x16 (0 dB to +24 dB) the analog
gain value. The resolution is set in x0.01 steps (0.05 dB to 0.08 dB depending on the setting
value). Values are configured by multipliers. For example, the values set for x1 and x16 are
100 and 1600 respectively.
•
For the GO-5101C-PGE, the [Digital Red] (digital R gain) and [Digital Blue] (digital B gain)
can be set to a value from x0.45 to x5.62 (–7 dB to +15 dB) the [Digital All] (master gain)
value. The resolution is set in 0.1 dB steps. Specify 0 for 0 dB, negative values for settings
below 0, and positive values for settings above 0.
Adjusting the White Balance (GO-5101C-PGE only)
Adjust the white balance using R and B gain. The white balance can also be adjusted automatically.
Display the camera image and adjust the image quality.
Displaying the Image
Display the image captured by the camera.
When you push [Play] button, the camera image appears in right area.
eBUS Player for JAI
File Tools Help
Select / Connect
Disconnect
N/A
N/A
XXXXXXXXXXX
JAI Corporation
GO-5101C-PGE
JAI_DEMO
IP address
MAC address
GUID
Vendor
Model
Name
Source
Mode
Play
Stop
Communication control
Device control
Image stream control
Stream: 0 images N/A FPS N/A Mbps Display: N/A FPS
Error count: 0 Last error: N/A
Warnings: N/A
Connection
Acquisition Control