EL-2800M-CXP / EL-2800C-CXP
- 22 -
5.5.10 Pulse Generator Inverter
Clear Source Signal can have polarity inverted.
5.5.11 Pulse Generator Setting table
Table - 13
Pulse Generator setting parameters
Display Name
Value
Clock Pre-scaler
1 to 4096
Pulse Generator Clock (MHz)
[Pixel Clock:108MHz]÷[Clock Pre-scaler]
Pulse Generator Selector
- Pulse Generator 0
- Pulse Generator 1
- Pulse Generator 2
- Pulse Generator 3
- Pulse Generator Length
1 to 1048575
- Pulse Generator Length (ms)
(
[Clock Source]÷[Clock Pre-scaler]
)
-1
x [Pulse Generator Length]
- Pulse Generator Frequency (Hz)
[
Pulse Generator Length (ms)
]
-1
- Pulse Generator Start Point
0 to 1048574
- Pulse Generator Start Point (ms)
(
[Clock Source]÷[Clock Pre-scaler]
)
-1
x [Pulse Generator Start Point]
- Pulse Generator End Point
1 to 1048575
- Pulse Generator End Point (ms)
(
[Clock Source]÷[Clock Pre-scaler]
)
-1
x [Pulse Generator End Point]
- Pulse Generator pulse-width (ms)
[ Pulse Generator End Point (ms)]
-
[ Pulse Generator Start Point (ms)]
- Pulse Generator Repeat Count
0 to 255
- Pulse Generator Clear Activation
Clear Mode for the Pulse Generators
- Off
- High Level
- Low level
- Rising Edge
- Falling Edge
- Pulse Generator Clear Sync Mode
- Async mode
- Sync mode
- Pulse Generator Clear Source
- Low
- High
- Frame Trigger Wait
- Frame Active
- Exposure Active
- Acquisition Trigger Wait
- Acquisition Active
- FVAL
- LVAL
- PulseGenerator0
- PulseGenerator1
- PulseGenerator2
- PulseGenerator3
- TTL_In1
- Opt In
- Trigger packet
- Nand0 Out
- Nand1 Out
- Line 10 - TTL 2 In
- Line 11 - LVDS 1 In
- Pulse Generator Inverter (Polarity)
Pulse Generator Clear Inverter
- False
- True
Note:
1. If
Pulse Generator Repeat Count is set to “0”, the pulse generator works in Free Running mode.