AP-1600T-USB | AP-3200T-USB | User Manual (Ver. 2.0)
Setting List (Feature Properties)
- 80 -
DigitalIOControl
Related Topic:
GPIO (Digital Input/Output Settings)
Configure settings for digital input/output.
Digital IO Control Item
Setting Range
Default
Description
Line Selector
Line1-TTLOut1
Line2-OptOut1
Line5-OptIn1
Line6-OptIn2
TimeStampReset
NAND0In1
NAND0In2
NAND1In1
NAND1In2
Line2-
OptOut1
Select the input/ output to configure.
Line Mode
Input
Output
Output
Display the input/ output status (whether it is input or
output).
Line Inverter
True
False
False
Enable/disable polarity inversion for the selected input
signal or output signal.
Line Status
True
False
False
Display the status of the input signal or output signal (True:
High, False: Low).
LineSource
Low
High
Acquisition Trigger Wait
Acquisition Active
Frame Trigger Wait
Frame Active
Exposure Active
FVAL
LVAL
Pulse Generator 0 ~ 3
User Output 0 ~ 3
Line5-OptoIn1
Line6-OptoIn2
Nand 0 Out
Nand 1 Out
-
Select the line source signal for the item selected in Line
Selector.
Default
Line Selector
Low
All except below
Exposure Active
Line1 - TTL Out1
Off
TimeStampReset
Line Format
NoConnect
TTL
OptoCoupled
InternalSignal
-
Display the current I/F type.