AM-800CL / AB-800CL
- 26 -
6.4. Horizontal timing
6.4.1 If the binning control is 0=OFF or 2=2x1
1LVAL 3724clk = 46.55
μ
s 1clk=25ns (via Camera Link)
(Exposure start line
1LVAL 3964 clk = 49.55
μ
s)
Fig.25 Horizontal timing (Vertical binning OFF)
6.4.2 If the binning control is 1=1x2 or 3=2x2
1LVAL 4044clk = 50.55
μ
s 1clk=25ns (via Camera Link)
(Exposure starting line
1LVAL 4364 clk = 54.55
μ
s)
Fig.26 Horizontal timing (Vertical binning ON)
6.4.3 DVAL output if the Binning control is set to 2=2x1or 3=2x2
If the Binning control is set to 2=2x1 or 3=2x2, DVAL is output in one pixel period within the
effective output period. Data is output by adding two pixels in horizontally as described
below.
Fig.27 DVAL in the vertical binning
1+2
3+4
5+6
7+8
3289
+ 3290
3291
+3292
3293
+3294
3295
+3296
12.5ns
12.5ns
3296 clk
DATA
DVAL