AM-1600GE / AB-1600GE
38
Horizontal Timing
The horizontal timing is the same as the Normal continuous mode.
Fig.24 Horizontal Timing for Partial Scanning
8.6.5 Vertical binning (AM-1600GE only)
This function is available only for AM-1600GE.
The AM-1600GE has vertical binning mode. The vertical binning function combines charges
from two adjacent rows, reducing the resolution to half and at the same time increasing
frame rate and sensitivity. By activating this function, the frame rate is increased to 5.63 fps.
Important Note
Vertical binning cannot be used together with Partial scanning.
Frame rate calculation formula
The frame rate can be calculated as follows:
1 line in 2x binning mode = 106.66
μ
s
Total lines = 1665 lines
Frame rate = 1/(3200*1665*33.333333/1000000000)=5.63 fps
EEN
LVAL
i nt_XSUB
i nt_XSG
(Exposure)
(CCD out)
1 CL K = 3 3 . 3 3 n s ( 3 0 . 0 0 MHz )
DVAL
L_DATA out
E f f e c t i v e P i x e l s
B L
DM
2 8 16
R e s e r v e
1
2
2 4 3 6
4 8 0
5 2 4
4 6
2480 clk
2960 clk