Page 1: ...1027E 1102 AM 200CL AB 200CL 2MP Digital Progressive Scan Monochrome and Color Camera Document Version 1 3 AMAB 200CL_Ver 1 3_Mar2012 User Manual ...

Page 2: ...ipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inte...

Page 3: ...ucts known as China RoHS The table shows contained Hazardous Substances in this camera mark shows that the environment friendly use period of contained Hazardous Substances is 15 years 嶷勣廣吭並 嗤蕎 嗤墾麗嵎賜圷殆兆各式根楚燕 功象嶄鯖繁酎慌才忽佚連恢匍何〆窮徨佚連恢瞳麟半陣崙砿尖一隈〇 云恢瞳ゞ 嗤蕎 嗤 墾麗嵎賜圷殆兆各式根楚燕 泌和 桟隠聞喘豚 窮徨佚連恢瞳嶄根嗤議嗤蕎嗤墾麗嵎賜圷殆壓屎械聞喘議訳周和音氏窟伏翌 亶賜融延 窮徨佚連恢瞳喘薩聞喘乎窮徨佚連恢瞳音氏斤桟廠夛撹冢嶷麟半 賜斤児繁附 夏恢夛撹冢嶷鱒墾議豚 方忖仝15々葎豚 15定 ...

Page 4: ...ucts known as China RoHS The table shows contained Hazardous Substances in this camera mark shows that the environment friendly use period of contained Hazardous Substances is 15 years 嶷勣廣吭並 嗤蕎 嗤墾麗嵎賜圷殆兆各式根楚燕 功象嶄鯖繁酎慌才忽佚連恢匍何〆窮徨佚連恢瞳麟半陣崙砿尖一隈〇 云恢瞳ゞ 嗤蕎 嗤 墾麗嵎賜圷殆兆各式根楚燕 泌和 桟隠聞喘豚 窮徨佚連恢瞳嶄根嗤議嗤蕎嗤墾麗嵎賜圷殆壓屎械聞喘議訳周和音氏窟伏翌 亶賜融延 窮徨佚連恢瞳喘薩聞喘乎窮徨佚連恢瞳音氏斤桟廠夛撹冢嶷麟半 賜斤児繁附 夏恢夛撹冢嶷鱒墾議豚 方忖仝15々葎豚 15定 ...

Page 5: ...put 1 tap output 16 5 4 2 Partial scan readout AOI Commands STL ETL 16 5 4 2 1 Frame rate calculation if AOI is set 17 5 4 2 2 2 tap output 17 5 4 2 2a Binning OFF 17 5 4 2 2b Binning ON 18 5 4 2 3 1 tap output 18 5 4 2 3a Binning OFF 18 5 4 2 3b Binning ON 18 5 4 2 4 Setting example 1 2 tap output the binning control is OFF or 2x1 19 5 4 2 5 Setting example 2 19 5 4 2 6 Setting example 3 20 5 4 2...

Page 6: ...s operation 31 7 6 Timed mode so called EPS operation 32 7 6 1 If the overlap setting is OFF 33 7 6 2 If the overlap setting is Readout 33 7 7 Trigger width mode so called PWC 34 7 7 1 If the overlap setting is Non Overlap 34 7 7 2 If the overlap setting is Readout 35 7 8 Pre dump mode so called RCT 35 7 9 PIV Particle Image Velocimetry 37 7 10 Operation and function matrix 38 8 Other functions 39...

Page 7: ...8 11 External appearance and dimensions 60 12 Specifications 61 12 1 Spectral response 61 12 2 Specifications table 62 Appendix 64 1 Precautions 64 2 Typical Sensor Characteristics 64 3 Caution when mounting a lens on the camera 64 4 Caution when mounting the camera 65 5 Exportation 65 6 References 65 Manual change history 66 User s Record 67 ...

Page 8: ...um length of the Camera Link cable may also be impacted The AM 200CL and AB 200CL are high resolution and high frame rate cameras with 1600 h x 1200 v pixel resolution and a 68fps frame rate for 2 tap output or a 34fps frame rate for 1 tap output Accordingly the amount of data produced is very large If the output is set at 10 bits or 12 bits per pixel the total data stream is approx 2 0 Gbit sec a...

Page 9: ...d field of view The digital output is through a Camera Link digital interface with 8 bits 10 bits or 12 bits of pixel bit depth For the RGB output only 8 bits is available The latest version of this manual can be downloaded from www jai com The latest version of Camera Control Tool for the AM 200CL and AB 200CL can be downloaded from www jai com For camera revision history please contact your loca...

Page 10: ...vertical binning AM 200CL only and AOI Area Of Interest modes for faster frame rate 3dB to 24dB gain control for AM 200CL and 0dB to 24dB for AB 200CL 10μs 1 100 000 to 2 seconds exposure control in 1μs step Exposure Timed control mode Timed trigger width for exposure control Pre dump RCT and PIV modes for specific applications Auto gain control Various pre processing circuits are provided Program...

Page 11: ...ear protrusion on C mount lens must be less than 10 0mm 2 Note When a Camera Link cable is connected to the camera please do not excessively tighten screws by using a driver The Camera Link receptacle on the camera might be damaged For security the strength to tighten screws is less than 0 291 Newton meter Nm Tightening by hand is sufficient in order to achieve this 3 Note The part number for the ...

Page 12: ...Power connected initiating Steady green Camera is operating in Continuous mode Flashing green The camera is receiving external triggering Note The interval of flashing does not correspond with external trigger duration Fig 2 Rear panel DC IN TRIG D IGITAL I O POWER TRIG DC IN TRIG D IGITAL I O POWER TRIG ...

Page 13: ...r by internal switch setting The default is the complementary emitter follower circuit See chapter 5 1 3 for the details 2 Factory default is trigger via Camera Link 5 1 2 Camera Link connector 5 1 2 1 Figure Type 26 pin MDR connector 3M 10226 1A10PL Fig 6 Camera Link connector Pin no Signal Remarks 1 GND 2 DC input 12V to 24V 3 GND 4 Iris video Only for Continuous and Pre dump modes 5 GND 6 NC 7 ...

Page 14: ...N C 12 25 N C 13 26 Shield GND 5 1 3 DIP switch SW500 The XEEN output through HIROSE 12 pin 9 can be connected to the complementary emitter follower circuit or the open collector circuit DIP switch SW500 is used to change circuits Factory default setting is the complementary emitter follower circuit Fig 5 SW500 PK9137A board can be found at the top of the camera after removing the top cover 1 3 4 ...

Page 15: ...P B4 TAP B8 TAP B8 G4 Tx13 Port B5 TAP B5 TAP B9 TAP B9 G5 Tx14 Port B6 TAP B6 TAP B10 G6 Tx10 Port B7 TAP B7 TAP B11 G7 Tx11 Port C0 TAP B0 TAP B0 B0 Tx15 Port C1 TAP B1 TAP B1 B1 Tx18 Port C2 TAP B2 TAP B2 B2 Tx19 Port C3 TAP B3 TAP B3 B3 Tx20 Port C4 TAP B4 TAP B4 B4 Tx21 Port C5 TAP B5 TAP B5 B5 Tx22 Port C6 TAP B6 TAP B6 B6 Tx16 Port C7 TAP B7 TAP B7 B7 Tx17 LVAL Tx24 FVAL Tx25 DVAL Tx26 EEN ...

Page 16: ...N output XEEN is on pin 9 of the 12 pin Hirose connector The output uses either a complementary emitter follower circuit or open collector The output of the complementary emitter follower circuit is 3 V no termination When the open collector output is used the maximum current is 120mA However if the current is more than 50mA use thicker cable for connecting pins 8 and 9 If a thinner cable is used ...

Page 17: ...tput 2 tap output The AM 200CL and AB 200CL have a 4 tap readout from the CCD The 4 tap output is combined horizontally to output 2 taps through the Camera Link interface The command SDT Sensor Digitization Taps can select 0 for 2 taps and 1 for 1 tap If 2 taps is selected the monochrome or Bayer output 8 bits 10 bits or 12 bits can be output through the Camera link interface divided into top and ...

Page 18: ...f each line cannot be changed In the AM 200CL and AB 200CL RGB output The Offset Y and Height can be set in 1 line increments For the AB 200CL Bayer mode output can be set in 2 line steps STL Offset Y Read out start line ETL Height Readout line numbers Fig 13 AOI setting Note for AOI setting In the AM 200CL and AB 200CL the frame rate setting has priority If AOI is used the frame rate setting shou...

Page 19: ...ng two formulas to calculate frame lines A and frame lines B Use the larger number of frame lines for calculating the frame rate If they are the same number of lines either one can be used Frame lines A Roundup Offset 1 4 600 Offset 10 Frame lines B Roundup 1201 Offset Height 4 Offset Height 600 10 Frame rate Hz 1 frame lines number x 0 00002405 2 If the readout is only in the upper TAP In this ca...

Page 20: ... 600 Roundup Offset 1 4 Roundup 600 Offset height 4 Height 2 10 Frame lines number Frame rate Hz 1 Frame number x 0 0000264 3 If the readout is only in the lower TAP In this case Offset 600 Roundup 1200 Offset Height 4 Roundup Offset 600 4 Height 2 10 Frame lines number Frame rate Hz 1 Frame lines number x 0 0000264 5 4 2 3 1 tap output 5 4 2 3a Binning OFF If the bit allocation is set 8 10 or 12 ...

Page 21: ...0 150 273 152 30 1 16 0 75 218 190 73 525 75 217 191 61 562 75 189 220 0 600 75 217 191 61 1125 75 217 191 61 5 4 2 5 Setting example 2 2 tap output and the binning control is 1x2 or 2x2 Partial Offset Height Frame Line Frame Frequency Full 0 1200 311 121 79 1 2 0 600 310 122 18 300 600 236 160 5 600 600 310 122 18 1 4 0 300 235 161 18 300 300 235 161 18 450 300 198 191 3 600 300 235 161 18 900 30...

Page 22: ...13 1 8 Any 150 357 106 10 1 16 Any 75 339 111 73 5 4 3 Binning Command BNC Only for AM 200CL This function is available only for AM 200CL In binning mode adjacent pixels in the horizontal direction and or vertical direction are combined and output as one pixel The possible combinations are shown below Fig 15 Binning modes Binning achieves a higher frame rate as well as better sensitivity On the ot...

Page 23: ...en lines as shown below If AOI is used Offset Y can be set every 2 lines and therefore it always starts with a GRG sequence signal out Gr B Gr H7 Gr B Gr R Gr R Gb B Gb R H3 H4 H5 H6 Gr R V1 V2 V3 H1 H2 Gr R Gr R B Gb Fig 16 Bayer sequence 6 Sensor layout and timing 6 1 Sensor layout Fig 18 Sensor layout ...

Page 24: ...ng OFF AOI default 6 2 1 2 AOI setting Fig 19 Vertical timing 2 tap output Binning OFF AOI setting Frame rate examples when the start line and the end line are set as follows Offset HEGHT A L B L C L Total line L Frame rate Hz 270 600 103 300 0 408 101 6 404 272 167 136 0 308 135 0 134 272 34 272 49 364 114 2 202 136 51 136 66 263 158 0 LVAL FVAL DVAL DATA EEN XEEN CCD Exposure Valid Data 5L 6L 60...

Page 25: ...0 Vertical timing 2 taps output Binning ON AOI initial 6 2 2 2 AOI setting Fig 21 Vertical timing 2 taps output Binning ON AOI setting LVAL FVAL DVAL DATA EEN XEEN CCD Expsoure Valid data A B C 5L Offset HEGHT A L B L C L Total line L Frame rate Hz 270 600 88 150 0 243 155 8 404 272 137 68 0 210 180 3 134 272 34 136 49 229 165 4 202 136 56 68 51 195 194 2 ...

Page 26: ... 34 1fps Fig 22 Vertical timing 1 tap output Binning OFF 6 3 1 2 AOI setting Fig 23 Vertical timing 1 tap output Binning OFF Offset HEGHT A L B L C L Total line L Frame rate Hz 200 800 56 800 58 919 45 2 300 600 81 600 83 769 54 0 450 300 118 300 121 544 76 4 524 152 137 152 139 433 96 0 LVAL FVAL DVAL DATA CCD Exposure EEN XEEN Valid Data 5L 6L 1200L 8L LVAL FVAL DVAL DATA EEN XEEN CCD Expsoure V...

Page 27: ... 1tap output Binning ON Initial AOI 6 34 2 AOI setting Offset HE GHT A L B L C L Total line L Frame rate Hz 200 800 56 400 58 519 72 9 300 600 81 300 83 469 80 7 450 300 118 150 121 394 96 1 524 152 137 76 139 357 106 1 Fig 25 Vertical timing 1 taps output Binning ON AOI setting LVAL FVAL DVAL DATA CCD Exposure EEN XEEN Valid Data 5L 6L 600L 8L LVAL FVAL DVAL DATA EEN XEEN CCD Expsoure Valid data ...

Page 28: ...1clk 12 5ns via Camera Link Exposure Start Line 1LVAL 2298clk 28 725μs Fig 27 Horizontal timing Vertical binning ON 6 4 3 DVAL output if the Binning control is set to 2 2x1 or 3 2x2 If the Binning control is set to 2 2x1 or 3 2x2 DVAL is output in one pixel period within the effective output period Data is output by adding two pixels in horizontally as described below Fig 28 DVAL in the vertical b...

Page 29: ...t Ordinary Exposure start OFF 2x1 276clk 462clk 1924clk 24 05μs 2110clk 26 375μs 1x2 2x2 464lk 650clk 2112clk 26 4μs 2298clk 28 725μs Fig 29 LVAL LOW period varies 2 When the trigger control mode is set to ON and Overlap is set to Readout LVAL LOW period is 1LVAL as the maximum Fig 30 LVAL LOW period if Overlap is set to Readout EEN LVAL Trigger EEN LVAL In the period right after the exposure star...

Page 30: ...mage can be increased Maximum recommended exposure time is 2 seconds This function is available when the trigger mode is OFF The setting range is Shortest Longest 68Hz 1 frame period 0 5Hz 14 69ms 2 0 seconds Notes for setting 1 The value for setting is the number of line 2 The actual frame rate is calculated in the following formula Frame rate 1 Setting value Line number x 1 line period Where 1 l...

Page 31: ...d can be set if EM Exposure mode is set at 1 or 2 Minimum exposure time Maximum exposure time Full pixels 10μs 2 sec Note Binning HxV 1 x 2 2 x 1 2 x 2 Note The AM 200CL and AB 200CL are designed so that frame rate has priority over exposure time Accordingly if the exposure time is set at a longer accumulation time than 1 frame 16 64ms the frame rate should be set at a longer time than the exposur...

Page 32: ... is activated and at the low level the read out is activated TA 1 Low During the low level of trigger the accumulation is activated and at the high level the read out is activated 7 3 3 Trigger Overlap Command TO This function sets if a trigger pulse can be accepted while data is being read out or not TO 0 OFF The trigger pulse is not accepted during CCD readout This works the same as the LVAL asy...

Page 33: ...t Primary settings to use this mode Sensor Digitization Taps SDT 0 Two taps SDT 1 One tap Acquisition Frame Rate AR 1 42964 Trigger control Trigger mode TM 0 OFF Exposure settings Exposure mode EM 1 Exposure time PE 10μs 2000000μs or Select Auto shutter control ASC Exposure time auto ASC 1 ON Exposure time auto speed ASCS 1 16 Default is 8 Exposure time auto max ASCEA 10 1048575 μs unit Exposure t...

Page 34: ...μs Trigger control Trigger mode TM 1 ON Trigger overlap TO 0 OFF or 1 Readout OFF LVALsync Readout LVALsync async automatic setting Trigger source TI 0 Camera Link default or 1 Hirose 12 pin Trigger Activation TA 0 Rising edge 1 Falling edge Note The AM 200CL and AB 200CL prioritize the frame rate over the exposure time If the exposure time is set at longer than 15 56ms 1 frame period the frame ra...

Page 35: ...2 t3 Off 2 x 1 4 38μs 0 05μs 2L min 6 5L to 7 5L 1 x 2 2 x 2 7 06μs 0 05μs 2L min 6 5L to 7 5L Fig 31 Non Overlap 7 6 2 If the overlap setting is Readout Binning mode t1 t2 t3 OFF 2x1 28 44μs 0 05μs 2L min 6 5L to 7 5L 1x2 2x2 33 46μs 0 05μs 2l min 6 5L to 7 5L Fig 32 Readout ...

Page 36: ... control Trigger mode TM 1 ON Trigger overlap TO 0 OFF or 1 Readout OFF LVALsync Readout LVALsync async automatic setting Trigger source TI 0 Camera Link default or 1 Hirose 12 pin Trigger Activation TA 0 Rising edge 1 Falling edge 2 Any edge Minimum interval of the trigger pulse 2 tap output FULL 2 3 AOI 1 2 AOI 1 4 AOI 1 8 AOI Minimum frame line 614 464 389 276 220 1 tap output FULL 2 3 AOI 1 2 ...

Page 37: ...rformed This fast dump period is 5 275ms in the case of Binning OFF When the accumulated signal against the trigger is read out FVAL LVAL and DVAL are output too The frame rate for full pixels readout is 2 tap output 68fps Fast dump period Exposure time 1 tap output 34 2fps Fast dump period Exposure time Primary settings to use this mode Sensor Digitization Taps SDT 0 Two taps SDT 1 One tap Acquis...

Page 38: ...he read out area for each AOI is the centered readout same lines for upper and lower Note The minimum frame rate figures in the above table do not include the exposure time Binning Mode 2 taps t1 t2 Off 2 x 1 4 90ms 0 05μs 6 5L to 7 5L 1 x 2 2 x 2 4 91ms 0 05μs 6 5L to 7 5L Binning Mode 1 tap t1 t2 Off 2 x 1 9 80ms 0 05μs 6 5L to 7 5L 1 x 2 2 x 2 9 81ms 0 05μs 6 5L to 7 5L Fig 35 Pre dump mode tim...

Page 39: ... Timing specifications for 2 tap output time name description Time Binnig Control Off 2x1 Binnig Control 1x2 2x2 td Exposure beginning delay 5 24us 7 96us te1 First exposure time period 10us 14 694ms 10us 8 272ms te2 Second exposure time 14 694ms frame rate 8 272ms frame rate itf Interframing time 5 97us 5 97us tframe1 First Frame read out 14 574ms max 606L 8 139ms max 306L tframe2 Second Frame re...

Page 40: ...peration and function matrix Operation mode Exposure control Exposure auto Binning AOI Auto Iris output Overlap Note Continuous Timed EPS Trigger width PWC PreDump RCT Non Overlap JAI_PIV Non Overlap Exposure Sequence Non Overlap ...

Page 41: ...GJUT1 GJUT2 GJUT3 The Tap control function adjusts automatically or manually the OFFSET and the gain differences between the upper and lower taps and the right and left taps The sensor used in the AM 200CLand AB 200CL divides the effective image area into 4 four areas as shown in the figure 30 in order to achieve its fast frame rate The reference tap for all adjustments is Tap A AWA Adjust the dif...

Page 42: ...CEA Sets the maximum exposure in the ASC mode ASCEI Sets the minimum exposure in the ASC mode Note This function works only in Continuous mode or Pre dump mode 8 5 Auto white balance Related commands AWB PGS PGR PGGR PGGB PGB In this function the gain of each R Gr Gb and B color can be individually adjusted to get the proper white balance B3 Gb2 B4 B1 Gb1 B2 Gr1 R Gr2 Fig 39 Auto white balance To ...

Page 43: ...at can be compensated is up to 64 pixels per tap for a total of 256 pixels The built in compensation circuit for the AM 200CL and AB 200CL uses compensation data collected in the factory and can be turned ON or OFF The default setting is OFF Fig 40 Blemish compensation Note If defective pixels are found consecutively in the horizontal direction the blemish compensation circuit does not work 8 7 LU...

Page 44: ...on 8 9 Flat Field Correction FFC Command SDR This function compensates for shading caused by the lens or the light source used The method to compensate the shading is to measure the highest luminance level in the image and use that data as the reference Luminance levels of other areas are then adjusted so that the level of the entire area is equal The block for compensation is 64 pixels x 64 pixel...

Page 45: ... The AB 200CL uses a CCD with an RGB Bayer pattern If the Bayer color interpolation is not used the following RAW data can be output Gr R Gr R B Gb B Gb Gr R Gr R Gr R B Gb Gr R B Gb B Gb B Gb B Gb Gr R B Gb Gr R B Gb Gr R B Gb Gr R Fig 44 Bayer pattern The RAW data contains only luminance information for each color and outputs as a monochrome signal The Bayer color interpolation can complement la...

Page 46: ...s of values which can be read out by the TMPO command The display resolution in the JAI camera control tool is 1 ºC 8 13 ALC In the AM 200CL and AB 200CL auto gain auto shutter and auto iris functions can be combined to provide a wide ranging automatic exposure control from dark to bright or vice versa The functions are applied in the sequence shown below and if one function is disabled the linkag...

Page 47: ...00 video level Please note that ALC function is available only for the continuous mode Gain is fixed at Min Dark Light changes Bright Auto Shutter Max Auto shutter operation Max Min User set Auto Shutter fixed at Min Iris diaphragm fixed Open Auto iris operation AGC works Auto shutter works Auto iris works AGC operation Max Min User set AGC Max Iris stops just before close Operation if light chang...

Page 48: ...e camera answers NN Parameter CR LF Transmit the following to have the camera s actual settings ST CR LF The camera answers A complete list of the current settings Transmit the following to have a command list HP CR LF The camera answers A list with all commands and possible settings Invalid parameters sent to camera 99 is an invalid parameter SH 99 CR LF The camera answers 02 Bad Parameters CR LF...

Page 49: ... settings and utility commands 1 Camera Status Request ST CR LF Actual setting 2 Online Help Request HP CR LF Command list 3 Firmware Version VN CR LF 3 digits e g 100 Version 1 00 4 Camera ID Request ID CR LF max 12 characters 5 Model Name Request MD CR LF max 12 characters 6 User ID UD Param CR LF UD CR LF User can save and load free text 12 or less characters 7 Error code ERRER Param CR LF ERRE...

Page 50: ... Trigger source TI Param CR LF TI CR LF 0 Line0 Camera Link 1 Line1 Hirose 12pin 3 Trigger Activation TA Param CR LF TA CR LF 0 Rising edge High 1 Falling edge Low are effective only EM 2 4 Trigger overlap TO Param CR LF TO CR LF 0 off 1 Read out F Exposure control 1 Exposure Mode EM Param CR LF EM CR LF 0 OFF 1 Timed 2 Trigger width 2 Exposure time PE Param CR LF PE CR LF 10μs 2000000μs Available...

Page 51: ...ue AGCGA Param CR L F AGCGA CR LF 0 to 672 AM 200CL 84 to 672 AB 200CL 7 Gain Auto Minimal gain value AGCGI Param CR LF AGCGI CR LF 84 to 588 AM 200CL 0 to 588 AB 200CL 8 Black Level BL Param CR LF BL CR LF 1024 to 1023 Digital User Setup Master H Balance Ratio 1 BalanceRatio RED PGR Param CR LF PGR CR LF 4533 17713 Data 8192 8192 7 10dB Only AB 200CL Pixel Gain for WB 2 BalanceRatio Blue PGB Para...

Page 52: ...s 512 Param 0 to 8191 After sending consecutive 512 data LUT data can be renewed J Gain and black level for TAP balance 1 Gain auto Tap Balance AWA Param CR LF 0 OFF 1 Once Run 2 Continuous 2 Request the Result of Gain auto Tap balance WBRS CR LF 0 Complete 1 Too Bright 2 Too dark 3 Timeout Error 4 Busy 5 Limit 6 Trig is not set as Normal 3 Fine Gain for Tap 2 GJUT2 Param CR LF GJUT2 CR LF 891 100...

Page 53: ...p balance BBRS CR LF 0 Complete 1 Too Bright 2 Too dark 3 Timeout Error 4 Busy 5 Limit 6 Trig is not set as Normal 14 Fine Black for tap 2 BL2 Param CR LF BL2 CR LF 512 to 511 Tap2 Black Fine For User 15 Fine Black for tap 3 BL3 Param CR LF BL3 CR LF 512 to 511 Tap3 Black Fine For User 16 Fine Black for tap 4 BL4 Param CR LF BL4 CR LF 512 to 511 Tap4 Black Fine For User 17 BayerPixel FineBlack for...

Page 54: ...h BMRC Param CR LF Param 2 White 3 Blemish Threshold White BMTHW Param CR L F BMTHW CR LF 0 to 16383 4 BLMP White H BMWH Param1 Param2 CR LF BMH Param1 CR LF Param1 Blemish No 1 to 256 Param2 H position 5 BLMP White V BMWV Param1 Param2 CR LF BMV Param1 CR LF Param1 Blemish No 1 to 256 Param2 V position L ALC control 1 Auto Iris Lens Control Signal output AIC Param CR LF AIC CR LF 0 off 1 on 2 Iri...

Page 55: ...am CR LF EXSQ CR LF 0 OFF 1 ON Available when EM 1 2 2 Exposure Sequence No N 1 16 PES N Param CR LF PES N CR LF 0 15 3 Exposure Repeat Time N 1 16 PER N Param CR LF PER N CR LF 0 15 4 Exposure Sequence Reset EXSR Param CR LF EXSR CR LF 0 OFF 1 ON Effective when EXSQ 1 Only command 1 is used In the firmware 1 is immediately turned to 0 5 Exposure Sequence End Point EXSEP Param CR LF EXSEP CR LF 0 ...

Page 56: ...μs Available when EXSQ 1 17 Exposure time 12 PE12 Param CR LF PE12 CR LF 10μs 2000000μs Available when EXSQ 1 18 Exposure time 13 PE13 Param CR LF PE13 CR LF 10μs 2000000μs Available when EXSQ 1 19 Exposure time 14 PE14 Param CR LF PE14 CR LF 10μs 2000000μs Available when EXSQ 1 20 Exposure time 15 PE15 Param CR LF PE14 CR LF 10μs 2000000μs Available when EXSQ 1 21 Exposure time 16 PE15 Param CR L...

Page 57: ... When the program is started the last settings for the program are loaded from the file CameraName ini 10 2 Camera Control Tool interface The Camera Control software consists of the main tool bar and associated tool windows When each icon in the main tool bar is clicked the associated window will open The program is refreshed after reboot The Camera control tool includes an About Window Communicat...

Page 58: ...boxes now RS 232CCommunication 1 Select COM ports from the CL Manufacturer COM ports list Box 2 Select the communication port where the serial cable is connected to the camera from the Serial Port list box or click the Auto button to search for a camera on communication port 1 to 16 The Serial Port list box and the Auto search button are only active when COM ports is selected Camera Link communica...

Page 59: ...era or click the Synchronize program to load all settings from the camera to the program Files When clicking the Write to File or Read from File button the user is prompted for a file using a standard file dialog New files are created if they do not already exist Files for camera settings have the cam extension Information about the communication port is not stored in the files All settings are au...

Page 60: ...AM 200CL AB 200CL 58 10 2 3 Camera Control Window 10 2 3 1 Exposure Control 10 2 3 2 Gain Control ...

Page 61: ...AM 200CL AB 200CL 59 10 2 3 3 Blemish Control When Open LUT table is clicked the left side window will open for example for blue channel ...

Page 62: ... 7 1 42 36 0 55 0 28 1 42 36 40 1 57 1 57 1 57 40 40 69 45 45 45 62 2 44 3 0 12 φ 30 φ 1 18 55 2 17 27 5 55 2 17 27 5 1 08 1 08 depth0 18 depth0 18 depth0 18 depth0 18 POWER TRIG DIGITAL I O DC IN TRIG POWER TRIG DIGITAL I O DC IN TRIG Outsi de si ze tol erance 0 3m m 4 M3 Depth 4 5 4 M3 Depth 4 5 4 M3 Depth 4 5 4 M3 Depth 4 5 ...

Page 63: ...AM 200CL AB 200CL 61 12 Specifications 12 1 Spectral response Fig 49 Spectral response AM 200CL Fig 50 Spectral response AB 200CL ...

Page 64: ... OFF Continuous 34 1fps 29 3ms Bayer output RGB color output 34 1fps 29 3ms Timed Trigger ON 34 1fps 29 3ms Bayer output RGB color output 34 1fps 29 3ms Trigger Width 34 1fps 29 3ms Bayer output RGB color output 34 1fps 29 3ms PIV 16fps 62 1ms Bayer output RGB color output 16fps 62 1ms Pre Dump 34 1fps Fast dump Exposure time Bayer output RGB color output 34 1fps Fast dump Exposure time Image Form...

Page 65: ...ck Blemish Compensation Bright Built in maximum 64 pixels for dark and bright compensation per 1 tap note black compensation is only by factory preset Color interpolation 3 x 3 interpolation matrix Test pattern OFF Black white Gray H ramp Gray V ramp white 100 OFF Color bar Gray H ramp Gray V ramp White 100 Temperature sensor 55 to 125ºC measuring range resolution is 0 0625ºC Serial communication ...

Page 66: ...ishes Over time some pixel defects can occur This does not have a practical effect on the operation of the camera These will show up as white spots blemishes Exposure to cosmic rays can cause blemishes to appear on the image sensor Please take care to avoid exposure to cosmic rays during transportation and storage It is recommended using sea shipment instead of air flight in order to limit the inf...

Page 67: ...ipod mounting plate please use the provided screws 5 Exportation When exporting this product please follow the export regulation of your own country 6 References 1 This manual can and datasheet for AM 200CL AB 200CL can be downloaded from www jai com 2 Camera control software can be downloaded from www jai com Camera chassis Fixing plate Mounting the camera to fixing plate 5 0mm 0 2mm Camera chass...

Page 68: ...evision Changes July 2011 Ver 1 0 New release Aug 2011 Ver 1 1 Correct s n for AB 200CL from 57dB to 55dB Sept 2011 Ver 1 2 Delete command EB since it is not implemented Mar 2012 Ver 1 3 Add the description for Acquisition frame rate Add ALC function ...

Page 69: ... manual are trademarks or registered trademarks of their respective owners JAI A S cannot be held responsible for any technical or typographical errors and reserves the right to make changes to products and documentation without prior notification Europe Middle East Africa Asia Pacific Americas Phone 45 4457 8888 Fax 45 4491 3252 Phone 81 45 440 0154 Fax 81 45 440 0166 Phone toll free 1 800 445 54...