Tool change
Item no. 10403015, Revision 03
29 ( 40 )
10.2.1
Changing the tool
Note: Ensure concentric run-out quality.
u
Only use tool mounts, clamping nuts, and clamping devices that are bal-
anced according to DIN ISO 1940 balance grade G DIN ISO 1940.
1
End face
2
Clamping nut
3
Collet
4
Tool Holder
5
Clamping device
Proceed as follows to change the tool:
Ü
Use the hook wrench to unfasten the clamping nut
and
the collet.
Ä
Make use of the hook wrench from the scope of delivery of the HF spindle.
Ü
Remove the tool.
Ü
Screw the clamping nut out.
Ü
Remove the collet from the taper of the mount.
Note: Ensure functionality.
All contamination damages the collet, clamping nut, tool mount, etc. As a re-
sult, the function of the HF spindle is no longer guaranteed.
u
Clean the collet.
u
Clean the clamping nut.
u
Clean the thread of the shaft.
u
Clean the inner taper of the shaft.
Ü
Lightly grease the thread of the clamping nut.
Ü
Push the collet into the taper of the mount.
Ü
Insert the tool.
Ü
Make sure that the shank of the clamped tool does not press on the inner
stop of the tool mount once the clamping nut has been tightened.
Ü
To prevent the clamping nut from loosening, tighten it again after a short
period of operation and when the shaft is at a standstill.