Daily start-up

Proceed  as  follows  to  preheat  the  grease  lubrication  of  the  bearing  and  to
protect it:

Ü

Operate the HF spindle with a clamped tool (without machining).

Ä

Approx. 2 minutes.

Ä

At maximum 50 % of the maximum permissible speed. 
(See Commissioning

 [

}

 26]

 section)

This brings the HF spindle to its operating temperature.

9.3

Shutdown signal

Use the option on the frequency converter of detecting the shutdown signal
from the shaft and forwarding this to the machine controller for evaluation.

9.4

Commissioning after storage

Ü

Do not put the HF spindle into operation until its temperature has adjusted
from the temperature of the storage location to the temperature of the us-
age location.

Ä

The temperature difference between the HF spindle and the usage lo-
cation should not exceed 10°C.

Ü

Carry out all steps in the "Maintenance

 [

}

 32]

" section.

Ü

Operate the HF spindle at a maximum of 50 % of the max. permissible
speed for approx. 5 minutes.

Ä

See Commissioning

 [

}

 26]

 section

Ü

Operate the HF spindle for approx. 2 more minutes at a maximum of 80 %
of the maximum permissible speed.

This preheats the grease lubrication of the bearing and protects it.

Summary of Contents for Z62-K360.12 S4AG1IP

Page 1: ...Manual Z62 K360 12 S4AG1IP High Frequency Spindle Pneumatic taper change...

Page 2: ...opment we reserve the right to make technical modifications and variations from the exact design described in the manual The text in this manual has been compiled with the utmost care However Nakanish...

Page 3: ...protection 20 6 7 Air borne noise emissions 21 7 Operating location 21 8 Installation 22 8 1 Installing the HF spindle 22 8 2 Diameter of media supply line 23 8 3 Cooling water 23 8 3 1 Quality of coo...

Page 4: ...Item no 10403012 Revision 10 4 40 Contents Translation of the original manual 15 Declaration of Incorporation 39...

Page 5: ...of the man ual carefully again 1 2 Explanation of symbols used To enable quick classification of information this manual uses visual aids in the form of symbols and text markings Notes are marked with...

Page 6: ...rvice set q C wrench q Transport packaging Check the high frequency spindle for completeness upon delivery 2 1 1 Service set q Felt cleaning taper q Collet grease 2 1 2 Optional accessories Available...

Page 7: ...h the HF spindle q Manual q The declaration of incorporation is part of the manual q Inspection protocol Check that the documentation supplied is complete when the spindle is delivered If necessary re...

Page 8: ...ing The HF spindle has been developed only for the following types of machining q Cutting q Drilling q Engraving q Grinding Contact Nakanishi Jaeger GmbH if other types of machining are required 3 2 P...

Page 9: ...re not approved for use in areas at risk of explosion Use in such areas may result in explosions u Do not use the HF spindle in potentially explosive atmospheres DANGER Due to flying parts The HF spin...

Page 10: ...ause chips to fly out with great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Inserting the shank Note Ensure fun...

Page 11: ...arding this to the machine controller for evaluation 4 3 Installation and maintenance Carry out installation cleaning and maintenance work only after shutting down the HF spindle and after the shaft h...

Page 12: ...quency converter FC Check whether the current voltage and frequency data of the HF spindle match the raw data for the frequency converter Use a motor supply line that is as short as possible Adjust th...

Page 13: ...emul sions from entering the HF spindle Check that air escapes at the front between the housing and the rotating parts of the HF spindle 5 5 Taper cleaning For guidelines on air quality see Air purit...

Page 14: ...tor poles pairs 1 Rated rotation speed 60 000 rpm Acceleration braking value Per second 10 000 rpm other values by consultation Characteristics Speed sensor Differential magneto resistor TTL Number of...

Page 15: ...Technical Specifications Item no 10403012 Revision 10 15 40 Inner taper run out 1 Axial run out 1 6 1 Dimensions Clamping range...

Page 16: ...04 22 856 27 860 37 684 47 509 56 761 rpm Frequency 167 250 333 417 500 667 833 1 000 Hz Rated power 0 192 0 289 0 419 0 524 0 633 0 853 1 044 1 249 kW Torque 0 21 0 21 0 22 0 22 0 22 0 22 0 21 0 21 N...

Page 17: ...078 1 243 1 808 2 076 2 503 kW Torque 0 48 0 479 0 452 0 473 0 432 0 474 0 425 0 428 Nm Voltage 68 93 111 128 149 184 214 249 V Current 10 10 4 10 6 10 5 10 9 11 10 5 10 6 A Cos 0 89 0 84 0 83 0 82 0...

Page 18: ...GN 0 5 WH 2x 0 14 0 5 RD 0 5 BU 0 5 WH 0 22 BN 0 22 VT 0 22 WH 0 25 BN 0 25 BU 0 25 BK 0 5 BN 0 5 BU 0 5 BK 0 75 BK 0 75 BU 0 75 BN 1 BN 1 BU 1 BK 1 5 BK 1 5 BU 1 5 BN 2 5 BN 2 5 BU 2 5 BK 4 BK 4 BU 4...

Page 19: ...cording to the positive temperature coefficient thermistor temperature TPTC small signal resistance Technical Specifications Type M135 Max operating voltage TA 0 40 C V max 30 V Max measuring voltage...

Page 20: ...ground Supply voltage U Rx Signal 8 V 220 1000 mV 8 V 450 2000 mV 12 V 220 1000 mV 12 V 680 3000 mV 15 V 220 1000 mV 15 V 680 3000 mV 24 V 220 1000 mV 24 V 680 3000 mV Unnecessary if a resistor is in...

Page 21: ...G Risk of injury due to flying parts The HF spindle operates at high speeds which may cause chips to fly out with great force u Never remove the protective devices of the machine or system u Always we...

Page 22: ...gs install the appropriate hose fittings Install the corresponding hoses in the hose fittings Make sure that the connections are flexible and free of strain Seal all connections for compressed air axi...

Page 23: ...s immediate corrosion on bare parts which is often unno ticeable at first but later leads to serious corrosion damage Do not use pure or distilled water Deposits in cooling channels due to unsuitable...

Page 24: ...n air quality see Air purity classes ISO 8573 1 24 section The adjustment value for the sealing air depends on the hose diameter and length Hose diameter DN 4 The setting value can be found in the fol...

Page 25: ...be observed Connect the vent for the cylinder The cylinder takes in air when clamping the taper tool Select the length of the hose so that its end protrudes out of the area re quired according to IP6...

Page 26: ...al forces q The clamping system is shifted q The balance of the HF spindle is affected q The bearing is damaged Example of design Clockwise Turn the shaft of the spindle at least ten times by hand Bef...

Page 27: ...rding this to the machine controller for evaluation 9 4 Commissioning after storage Do not put the HF spindle into operation until its temperature has adjusted from the temperature of the storage loca...

Page 28: ...use tools with the correct direction of rotation for the HF spindle Only use tool mounts with the correct HF spindle direction of rotation Set the direction of rotation of the HF spindle on the FC in...

Page 29: ...t tool mount etc As a re sult the function of the HF spindle is no longer guaranteed u Clean the collet u Clean the clamping nut u Clean the thread of the shaft u Clean the inner taper of the shaft Li...

Page 30: ...eumatic taper change During a tool change the tool mount is pressed out of the shaft by the cylin der 10 3 2 Installing the changing station Proceed as follows to install the changing station Drill a...

Page 31: ...Note the maximum speed for the selected tool u Note the maximum speed for the HF spindle u The maximum permissible speed of the HF spindle for commissioning processing is always the lowest specified...

Page 32: ...curately all contact sur faces of the HF spindle the mount for the HF spindle the tool mount and the tool holder must be clean Note Foreign matter reduces the service life u Do not use compressed air...

Page 33: ...HF spindle in horizontal position Store the HF spindle so that it is protected from moisture dust and other environmental influences Note the following storage conditions Temperature of storage locat...

Page 34: ...n More than 90 of the materials used in the HF spindle can be recycled alu minum stainless steel steel copper etc The HF spindle may not be disposed of with normal domestic waste Remove all non recycl...

Page 35: ...energy supply companies u Before commencing work switch off the power supply of the HF spindle Note Damage due to electrostatic discharge Do not touch the electrostatic sensitive components of the HF...

Page 36: ...equency converter has shut down q Check the error messages in the frequency converter man ual Tool change initiated q Turn off the pneumatic system for the tool change HF spindle becomes hot Cause Tro...

Page 37: ...d too tightly q Only tighten the clamping screws of the spindle holder manually q Do not use technical aids to clamp the HF spindle Bearings damaged q Contact Nakanishi Jaeger GmbH service No automati...

Page 38: ...serve all points in the Tool change 28 and Mainte nance 32 sections Frequency converter incorrectly set q Compare the values for the HF spindle with the set values on the frequency converter Machining...

Page 39: ...5 1 5 6 1 5 8 1 5 9 1 6 4 1 6 5 1 7 1 1 7 1 1 1 7 2 1 7 3 1 7 4 The incomplete machinery in its standard design complies furthermore with the following applicable regulations Applicable harmonized st...

Page 40: ...en GERMANY 49 0 6002 9123 0 sales anakanishi jaeger com www nakanishi jaeger com Serial number Type Z62 K360 12 S4AG1IP Item no 10403012 Revision 10 Date 01 09 2023 Language EN Jaeger Spindles North A...

Reviews: