JAGA NV    |   BRIZA 12 - JDPC.002  |   MANUEL   |  05.07.2021   |  V.08

3.   WARRANTY CONDITIONS 

1.  

The guarantee is valid only if the equipment is properly and correctly used, by its first owner and if 
installed in accordance with the norms and instructions as stipulated in the instruction leaflet and 
the current practices. 

2.  

The guarantee only applies to the equipment and the spare parts. Jaga has the choice between 
repair and replacement of the equipment or the spare parts. If there has been a change in the 
model, Jaga is authorised to replace the guaranteed equipment with an equivalent equipment or 
equivalent spare parts. In those cases where the guarantee claim is received, during the first six 
months after the start of the guarantee, on all labour and transport costs. 

3.  

The period of guarantee is mentioned in this certificate. A repair or replacement does not change 
anything to the original period of guarantee. 

4.  

No guarantee is granted on equipment or spare parts lacking information concerning type or 
series, or on equipment where this informations has been removed or altered, or on equipment 
that has been repaired or modified by persons not authorized by Jaga. 

5.  

The customer is responsible for the damage in the cases where the damage is due to errors of 
placement, fittings, electrical connections, faulty or damaged electrical installations or appliances, 
erroneous voltage or hydraulic pressure and all other errors not related to the product delivered 
by Jaga. The guarantee is also revoked when nonsuited parts are applied. The guarantee for our 
heat exchangers not valid if they are emptied at set times or during a certain period, or if they are 
heated by means of industrial water, steam or water saturated by great quantities of oxygen. The 
quality of the system water has to be in accordance with the VDI 2035-2 directives. The guarantee 
is also revoked when the heat exchangers are placed in aggressive atmospherical surroundings 
(ammonia, caustic substances). Lacquered radiators should not be used in humid spaces. Lacque-
red radiators should not be used in the following areas: above a bath with a built-in shower unit, in 
a shower cubical or next to it, in a swimming pool (chlorine) or in a sauna. 

6.  

Jaga does not give a guarantee on faulty equipment due to incorrect handling and/or use of the 
equipment, the dropping of the equipment or the transport without the necessary precautions, or 
for all equipment that is built in, in a way that it cannot be reached normally. The guarantee is valid 
only if the equipment is properly and correctly used, by its first owner and if installed in accordan-
ce with the norms and instructions as stipulated in the instruction leaflet and the current practices. 

7.  

In all cases where the guarantee is granted but where the intervention occurs later than 6 months 
after the start of the guarantee, and in all other cases, labour and transportation costs are calcu-
lated according to scales set by Jaga. Customers can get information on those scales either from 
our sales administration personnel, or from the maintenance engineer. .

8.  

All interventions not covered by the guarantee have to be paid in cash to the maintenance engi-
neer. 

9.  

The guarantee starts on the date of the invoice. If the invoice is not available, the serial number or 
the date of production prevails. 

10.  

Only the courts of judicial district Hasselt (Belgium) are authorised to deal with disputes arising 
from this guarantee. It will apply Belgian law even when sales involved are subjects of EU member 
states as well as non-EU member countries. 

Summary of Contents for BRIZA 12 S

Page 1: ...BRIZA 12 S JDPC 002 MANU L MONTAGEANLEITUNG INSTALLATION INSTRUCTIONS...

Page 2: ...CZ STR 3 STR 14 PG 25 PG 36 SK DE EN 2...

Page 3: ...tka v dy p stupn Pro zaji t n bezchybn instalace a bezprobl mov ho provozu si pe liv prostudujte a dodr ujte pokyny obsa en v t to p ru ce P ru ku uchovejte na bezpe n m m st P i manipulaci pou vejte...

Page 4: ...C Tw 280C Jednotka se spust p i teplot vody 28 C KONFIGURA N K D 0 10 VDC T VODY T OKOL TOPEN CHLAZEN STANDBY OFF VYPNUTO RE IM 1 2 3 A str 10 RU N MONITOROV N TEPLOTY VODY DPC BR21 x x DPC BR22 x x...

Page 5: ...ura n m k dem DPC BR22 Jednotka se spust p i teplot vody 18 C 1 Rychlost Jednotka b p ednastavenou rychlost A 1 2 S ovl dac m panelem DPC BR24 DPC BR25 U ivatel zvol na ovl dac m panelu po adovan re i...

Page 6: ...u n zv en sn en rychlosti kr tce stiskn te Rychlost 1 Rychlost 2 Rychlost 3 erven LED diody blikaj teplota vody pro vyt p n je p li n zk 28 C Modr LED diody blikaj teplota vody pro chlazen je p li vys...

Page 7: ...jde je li k dispozici dic sign l 0 10V a je dosa eno nastaven teploty Jednotka se spust p i teplot vody 28 C a d c m sign lu 0 10V Jednotka se spust p i teplot vody 18 C a d c m sign lu 0 10V Rychlost...

Page 8: ...notka se automaticky p epne do re imu topen jakmile je teplota vody o 4 C vy ne teplota v m stnosti Pokud je rozd l teploty vody o 1 C ni ne pokojov teplota jednotka se automaticky p epne do pohotovos...

Page 9: ...lot vody 28 C Auto change over automatick p ep n n Jednotka se spust p i posledn zvolen rychlosti 1 2 nebo 3 p i teplot vody 18 C Jednotka je v re imu Standby P i dosa en nastaven teploty zah j jednot...

Page 10: ...je t eba sn it teplotu vody 1 Spu t n re imu nastaven stiskn te a p idr te tla tko dokud erven LED dioda 5x neblikne 2 Kr tk m stisknut m tla tka nebo upravte nastavenou teplotu 12 C 14 C 16 C 18 C 2...

Page 11: ...nastavenou rychlost RYCHLOST OT EK 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 RYCHLOST OT EK 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 3 Po 30 sekund ch se nov nastaven automaticky...

Page 12: ...apn te nap jen Nejprve se rozsv t modr LED dioda po 2 sekund ch zelen LED dioda a nakonec po 4 sekund ch erven LED dioda Jakmile v echny 3 LED diody blikaj uvoln te tla tka 3 Ovlada se p epne do tov r...

Page 13: ...y v syst mu mus odpov dat na zen VDI 2035 Z ruka tak zanik jsou li otopn t lesa um st na a provozov na v agresivn m atmosferick m prost ed pavek raviny apod Lakovan radi tory nemaj b t um st ny nad va...

Page 14: ...si starostlivo pre tudujte a dodr ujte pokyny obsiahnut v tejto pr ru ke Pr ru ku uchovajte na bezpe nom mieste Pri manipul cii pou vajte ochrann pom cky Neodborn in tal cia m e sp sobi po kodenie pr...

Page 15: ...18 C Tw 280C Jednotka sa spust pri teplote vody 28 C KONFIGURA N K D 0 10 VDC T VODY T OKOLIA K RENIE CHLADEIE STANDBY OFF VYPNUT TYP OVL DACIEHO PANELA RE IM 1 2 3 A str 16 DPC BR21 x x DPC BR22 x x...

Page 16: ...n m k dom DPC BR22 Jednotka sa spust pri teplote vody 18 C 1 R chlos Jednotka be prednastavenou r chlos ou A 1 2 S ovl dac m panelom DPC BR24 DPC BR25 U vate zvol na ovl dacom paneli po adovan re im O...

Page 17: ...u n zv enie zn enie r chlosti kr tko stla te R chlos 1 R chlos 2 R chlos 3 erven LED di dy blikaj teplota vykurovacej vody je pr li n zka 28 C Modr LED di dy blikaj teplota vody na chladenie je pr li...

Page 18: ...dispoz cii riadiaci sign l 0 10 V a je dosiahnut nastaven teplota Jednotka sa spust pri teplote vody 28 C a riadiacom sign le 0 10V Jednotka sa spust pri teplote vody 18 C a riadiacom sign le 0 10V R...

Page 19: ...tka sa automaticky prepne do re imu k renia akon hle je teplota vody o 4 C vy ia ako teplota v miestnosti Ak je rozdiel teploty vody o 1 C ni ako izbov teplota jednotka sa automaticky prepne do pohoto...

Page 20: ...vody 28 C Auto change over automatick prep nanie Jednotka sa spust pri poslednej zvolenej r chlosti 1 2 alebo 3 pri teplote vod 18 C Jednotka je v re ime Standby Pri dosiahnut nastavenej teploty za ne...

Page 21: ...nia stla te a pridr te tla idlo k m erven LED di da 5x neblikne 2 Kr tkym stla en m tla idla alebo upravte nastaven teplotu 12 C 14 C 16 C 18 C 20 C 22 C 24 C 26 C Pri dosiahnut minim lnej teploty za...

Page 22: ...n r chlos R CHLOS OT OK 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 R CHLOS OT OK 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 3 Po 30 sekund ch sa nov nastavenia automaticky ulo ia a j...

Page 23: ...a Zapnite nap janie Najprv sa rozsvieti modr LED di da po 2 sekund ch zelen LED di da a nakoniec po 4 sekund ch erven LED di da Akon hle v etky 3 LED di dy blikaj uvo nite tla idl 3 Ovl da sa prepne d...

Page 24: ...e mus zodpoveda nariadenia VDI 2035 Z ruka tie zanik ak s vykurovacie teles umiestnen a prev dzkovan v agres vnom atmosf rickom prostred pavok ieraviny a pod Lakovan radi tory nemaj by umiestnen nad v...

Page 25: ...h sein Nur wenn der Inhalt dieser Anleitung strikt und umfassend beachtet wird k nnen Fehler vermieden werden und ist ein st rungsfreier Gebrauch m glich Die Nichtbeachtung der Sicherheitshinweise Mon...

Page 26: ...18 C sein bevor das Ger t startet Tw 280C Das Systemwasser muss h her als 28 C sein bevor das Ger t startet KONFIGURATIONSCODE 0 10VDC T WASSER T RAUM HEIZEN K HLEN STANDBY OFF TYP BEDIENTEIL MODUS 1...

Page 27: ...r erreicht ist 18 C 1 Geschwindigkeit Das Ger t l uft mit der eingestellten Geschwindigkeit A 1 2 Mit Bedienfeld DPC BR24 DPC BR25 Der Benutzer w hlt den gew nschten Modus manuell ber das Bedienfeld a...

Page 28: ...nken kurz dr cken Geschwindigkeit 1 Geschwindigkeit 2 Geschwindigkeit 3 Wenn die roten LEDS blinken dann ist die Wassertemperatur zu niedrig 28 C Wenn die blauen LEDS blinken dann ist die Wassertemper...

Page 29: ...obald ein 0 10V Steuersignal vorliegt und die eingestellte Wassertemperatur erreicht ist Das Ger t startet sobald die Wassertemperatur 28 C ist und ein 0 10V Steuersignal vorliegt Das Ger t startet so...

Page 30: ...ur ck Das Ger t wechselt automatisch in den Heizmodus sobald die Wassertemperatur 4 C ber der Raumtemperatur liegt Wenn die Wassertemperatur weniger als 1 C ber der Raumtemperatur liegt kehrt das Ger...

Page 31: ...artet mit der zuletzt eingestellten Geschwindigkeit 1 2 oder 3 sobald die Wassertemperatur erreicht ist 18 C Das Ger t startet automatisch einen neuen Zyklus sobald die eingestellte Wassertemperatur e...

Page 32: ...tur auf einen niedrigeren Wert einzustellen 1 Start einstellen Dr cken Sie die Taste der Platine bis die rote LED 5x blinkt 2 Dr cken Sie kurz die Taste oder um die Temperatur einzustellen 12 C 14 C 1...

Page 33: ...Geschwindigkeit einzustellen GESCHWINDIGKEIT 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 GESCHWINDIGKEIT 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 3 Nach 30 Sekunden werden die neuen...

Page 34: ...in Die blaue LED leuchtet Nach 2 Sek leuchtet die gr ne LED auf und 4 Sek sp ter leuchtet die rote LED auf Lassen Sie die Tasten los sobald alle 3 LEDs blinken 3 Der Controller schaltet wieder auf die...

Page 35: ...en werden Au erdem entf llt jegliche Garan tie wenn die Heizk rper mit Betriebswasser Dampf Chemikalien oder mit gr eren Sauerstoff angereicherten Mengen Wasser betrieben werden Die Qualit t das Syste...

Page 36: ...RIZA 12 BRIZA 22 NBN EN 60335 1 BASED ON EN60335 1 2012 A11 2014 NBN EN 60335 2 80 BASED ON EN 60335 2 80 2003 A1 2004 A2 2009 26 03 2018 Important info The unit must be installed by a certified insta...

Page 37: ...ling mode Tw 280C If the water temperature is above 28 C 82 F fans start in heating mode CONFIGURATION CODE 0 10VDC T WATER T SPACE HEATING COOLING STANDBY OFF TYPE CONTROL PANEL MODUS 1 2 3 A pg 38 M...

Page 38: ...ith configuration code DPC BR22 The unit starts when the water temperature 18 C 1 Speed The unit runs at the preset speed A 1 2 With control pannel DPC BR24 DPC BR25 The user manually selects the desi...

Page 39: ...anually changing the fan speed short press Speed 1 Speed 2 Speed 3 Red LEDs are flashing the water temperature for heating is too low 28 C Blue LEDs are flashing the water temperature for cooling is t...

Page 40: ...BMS The unit starts when there is a 0 10V control signal and the preset water temperature has been reached The unit starts if the water temperature is 28 C 82 F and the control signal is 0 10V The un...

Page 41: ...itch to standby The device automatically enters heating mode when the water temperature is 4 C 7 F above the room temperature If the differential between room and water temperature is less than 1 C 2...

Page 42: ...ter temperature 28 C Auto change over The unit starts at the last selected speed 1 2 or 3 if the water temperature 18 C The unit automatically starts a new cycle if the preset temperature is reached 3...

Page 43: ...eat pump it may be necessary to reduce the water temperature 1 Start setup mode Press and hold the button until the red LED flashes 5x and release 2 Short press the or button to adjust the set tempera...

Page 44: ...e preset speed FANSPEED 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 FANSPEED 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 3 After 30 seconds the new settings are automatically saved and...

Page 45: ...on the power again The blue LED will light up followed by the green LED 2 seconds later and the red LED 4 seconds later Release the buttons as soon as all 3 LEDs are flashing 3 The controller will ret...

Page 46: ...strial water steam or water saturated by great quantities of oxygen The quality of the system water has to be in accordance with the VDI 2035 2 directives The guarantee is also revoked when the heat e...

Page 47: ...EN 47 JAGA NV BRIZA 12 JDPC 002 MANUEL 05 07 2021 V 08 NOTES...

Page 48: ...Jaga N V Verbindingslaan 16 B 3590 Diepenbeek Tel 32 0 11 29 41 11 Fax 32 0 11 32 35 78 info jaga be www jaga com 27200 24100021 05 07 2021...

Reviews: