The location on the valve specified in the documentation features the nameplate which contains the following
data:
1.
Manufacturer's company and country of origin
2.
Manufacturer's company logo
3.
Polish construction mark (for the full range of diameter values)
4.
Alphanumerical reference designation for the bolt hole pattern drilling on the flange to be connected to
the piping (PN)
5.
CE marking
6.
Maximum permitted pressure (PS)
7.
Barcode
8.
Maximum / minimum permissible temperature (TS)
9.
Production serial no. in the calendar year
10.
Seal material
11.
Year of manufacture of the product
12.
Diameter, bore and nominal size (DN)
13.
Reference standard the product is compliant with
14.
Product name
The gate valves with GSK RAL certified corrosion protection feature the corresponding label:
1.
GSK logo
2.
Certificate title
3.
Certificate reference
number
The gate valves may feature additional markings, which depends on the market they are sold on, including. NF,
WRAS, DVGW and other.
4.
STORAGE & TRANSPORT
The products are packed
on EURO pallets (1200x800 mm) or in custom containers, as applicable. Store the valves
in
clean indoor rooms
without bacteriological
or chemical contaminants and at a room temperature between -20
°
C
and 70
°
C. Protect the paint coat and rubber parts from
prolonged exposure to UV radiation. The filters should be