J ADEVER SCALE CO., LTD
JWI-700W 7
5-2 Function Setting & Description of Parameter Values
Function Setting
1) Press key
MODE,
Setting item P00 displays momentarily. There are 14 available setting
items (P00-P13), indicated by Auxiliary display in the Lower Left corner.
2) Press key
M+
or key
M-
to
step through all the available setting items.
3) Press key
UNIT/LO
or
key
PRINT/HI
to set
the content values of setting items.
4) Press key
MODE
to save the settings and go back to the weighing mode.
Description of Parameter Values
1) P00 Set the period of inactivity before the scale automatically turns off. Options are
Aut.off =non power-off, Aut.5, Aut.10, Aut.30 , Aut.60 and Aut.90 (minutes).
2) P01 Set Check Weighing buzzer beep. Options are b-up, b-in, b-out and b-low
= There will be a warning sound when the weight of articles exceeds the upper limit.
=
There will be a warning sound when the weight of articles is between the upper
and lower limit (including the upper and lower limits).
= There will be a warning sound when the weight of articles is beyond the upper &
lower limit, and the weight is more than 20 divisions.
=
There will be a warning sound when the material quantity is less than the lower limit
and the weight is less than 20 divisions.
3)
P02
Set the desired external devices .Options are PC,
ET, SH-24
,
BP545D , Godex ,
ZEBRA and PCSCA
= Large LED display
= Computer output;
= SH-24 printer output (dot-matrix)
=BP545D printer output (Automatic-sticking), paper size: 5cm*3cm.
=Godex printer output (Automatic-sticking), paper size: 5cm*3cm.
=ZEBRA printer output (Automatic-sticking), paper size: 5cm*3cm.
= JADEVER WEIGHING SYSTEM