1. Introduction 

Thank you for deciding to purchase a JCL counting scale from Jadever. This goods has the 
excellent  performance  and  splendid  properties  under  severe  quality  management.  It  is 
recommended to read this manual in full before using it for good function application. 

2. Precautions 

  Place the scale on a flat and stable surface. See 3-3 Leveling the Scale for details. 

  Verify that the input voltage and the plug type matches the local AC power supply. See 4-3 

Power Supply. 

  Warm up the scale for 15 minutes before using it the first time.   

  Keep  the  scale  away  from  EMI  noise,  strong  wind  and  vibration,  which  might  cause 

incorrect reading. 

  Avoid sudden temperature changes (suitable operating temperature is between -5

~ 40

.) 

  Disconnect the power supply when cleaning the scale. 

  Do not immerse the scale in water or other liquids. 

  Service should be performed by authorized personnel only. 

 
3. Before Using the Product 

3-1 Unpacking and Checking 

Open the package and check the instrument for transport damage. Immediately inform your 
dealer if you have complaints or if parts are missing. The package should contain: 

● Scale body                                                                    ● User manual   

● Stainless steel and plastic weighing pans             

   

● Wire (power cord) 

3-2 Installing Components 

1)  Before  using  the  scale,  remove  the  shipping  protection  screw  (rotate  counterclockwise), 
which located underneath the scale and cork the 

plug buckle

.   

Note: the JCL-30K model was shipped without the shipping protection screw. 
2) Cover the weighing pans on the scale body properly. 

3-3 Leveling the Scale 

To compensate for small irregularities or inclinations at the location, the scale can be leveled. 
The scale is equipped with a level indicator at the front panel .Adjust the leveling feet until the 
air bubble in the indicator is centered as shown. 

 

 
 
 
 
 
Note: The scale should be leveled each time its location is changed. 

 
 

Summary of Contents for JCL-3K

Page 1: ...e and Multi point Calibration 8 7 Operation 7 1 Weighing 9 7 2 Tare Preset Tare 9 7 3 Checking function 7 3 1 Upper Lower Weight Limit Checking 10 7 3 2 Upper Lower Quantity Limit Checking 11 7 4 Basi...

Page 2: ...or other liquids Service should be performed by authorized personnel only 3 Before Using the Product 3 1 Unpacking and Checking Open the package and check the instrument for transport damage Immediat...

Page 3: ...ic and moisture Tare Preset Tare auto zero tracking Automatic counting accuracy improvement ACAI for enhanced counting accuracy HI OK LO quantity checking function Stainless steel weighing pan Weighin...

Page 4: ...tem is selected when setting buzz sounds See 5 Function Setting setting buzz sounds OK Lamp ON Indicating parameter item or is selected when setting buzz sounds LOW Lamp ON Indicating parameter item i...

Page 5: ...ht Window Displays weight of object on weighing pan or accumulated weight value 4 2 2 Keyboard 1 0 9 numeric keys Enters specific values for tare unit weight and other data entries 2 key Decimal point...

Page 6: ...n inputting the figures 4 3 Power Supply Power supply Please verify the local AC power source and switch the two stage switch to the proper place before plugging into the power outlet Alternative powe...

Page 7: ...he pan when it is stable 3 SET02 auto off time setting Options are off 5min 10min 30min and 60min Off close auto off function 5 10 30 60 Auto off with less than 9d of gross weight when there is not an...

Page 8: ...9 SET08 external equipment setting PC JMS Godex BIRCH ZEBRA DMP GP CK ET CX U KEY PC computer output JMS connect with weighing system GODEX Godex printer paper size 5cm 3cm BIRCH Birch printer paper s...

Page 9: ...or TARE to shift the figures Press key M HI or PRINT LO to modify the value or via numeric keys Press key M SAVE to save and shift the windows 16 SET15 weight memory parameter on off On display the l...

Page 10: ...tion procedure 5 Add another weight 500g to the current weight The window will show the total weights value Press TARE to complete Repeat this step to complete the calibrations of on3 on4 and on5 6 Pr...

Page 11: ...ZERO ESC Method 2 Enter the tare value by pressing the numeric botton the screen will show the tare value 1 Then press TARE 2 Place the items into the container and the weight of container will be tar...

Page 12: ...uld be more than or equal to 20e When changing the Hi Lo value the scale will activate the weighing checking function automatically If the Lo value is higher than Hi value then the Hi value will becom...

Page 13: ...1 Entering a Known Unit Weight and Unit weight Memory 1 Under the weighing mode use the numeric keys together with key to input unit weight value and then press UWS 2 Put the items on the weighing pan...

Page 14: ...higher reference weight is used to recalculate the averaging unit weight The process can be repeated as long as the additional weight is less than the previous reference weight Once this limit is exce...

Page 15: ...on Accumulation clear To clear the total accumulation data or the first 10 accumulation events press key MR or TARE to shift the events and then press key M HI to clear Symbol disappears when the tota...

Page 16: ...ng mode 7 7 The Control from PC to Scale Optional Step 1 Install the three in one board with RTC RS232 and RELAY Connect RS232 and choose the external equipment PC Step 2 Open the serial port to modif...

Page 17: ...t ERR3 Exceed the A D resolution range 1 Replace A D 2 Replace the load cell or contact the maintenance department ERR4 EEPROM Chksum failure Re weld EEPROM or contact the maintenance department ERR5...

Page 18: ...2012 02 20 13 14 15 N W 0 500 kg U W 0 0500 kg pcs Total 10pcs 2012 02 20 13 14 15 0 500 kg 2012 02 20 13 14 15 10 pcs 2012 02 20 13 14 15 10 pcs 2012 02 20 13 14 15 0 500 kg 1 000 kg ST GW 100 00 1 0...

Page 19: ...ge the scale design Appendix 2 Exporting data to PC in the form of EXCEL Introduction Connect the scale with PC and set the parameter of external device as EXCEL on the scale then you could export the...

Page 20: ...t Windows XP as a example 1 Press Start Run and enter access cpl OK 2 In the dialog box Accessibility Options enter General option choose Use Serial Keys and press Settings In the dialog box Settings...

Page 21: ...II 20 Export weighing data to Excel 1 Open Excel 2 Press Print then Excel will show Date and Weighing data 3 Use Format Cells to beautify Excel...

Page 22: ...to link computer system directly such as EXCEL Express System ERP system and so on This connector is compatible with windows2000 xp Vista win7 win8 Linux Android system and the weighing data will show...

Page 23: ...II 22 2 ERP System...

Reviews: