background image

OPERATING INSTRUCTIONS

Now that your Tirage Plus spa is in place, you are probably eager to take advantage of its unique designed-in

features—especially the patented Jacuzzi

º 

 Whirlpool Bath hydromassage performance.  Besides being a beautiful

addition to your indoor decor or outdoor landscaping, your Jacuzzi whirlpool spa will provide you with the ultimate in
spa pleasure.

Basic Control Set-Up

The control set-up on your Tirage spa is designed to give you fingertip control of the heater, air induction, lights and

whirlpool, filter,   and blower systems of your unit from inside or outside your spa.  Follow the basic control set-up
described below to familiarize yourself with the several functions of the control panels located on the top of the spa.

CAUTION

Do not turn on power to the spa unless it is filled with water to the normal water level. (See water line indicator
mark on skimmer frame.)  When the power is on, the built-in timer may activate the system even though the
SYSTEM is turned off at the control panel.  If the spa’s motor/pump is actuated when there is not sufficient
water in the unit, the circulation pump and heater could be irreparably damaged. Not heeding this caution will
nullify the warranty.  In addition to damaging the unit, operating the spa with insufficient water could cause
a fire.

6

Your spa is provided with a ground fault circuit
interrupter (GFCI). At initial start-up and at least
once a month thereafter, with power on, push the
test button located on the System Control Module.
The reset button should pop out.  Push this button in
to reset.  If the interrupter fails to operate in this
manner, there is a ground current flowing or a device
malfunctioning, indicating the possibility of electric
shock. Turn off power and do not use the spa
until the source of the breakdown has been
identified and corrected.

Using  a garden hose, fill the spa with water to the
water line indicator mark on the skimmer frame.

At the house service panel, turn on the circuit
breaker or switch that controls the electrical service
to your spa. (Make sure there is no other appliance
on that circuit.)

Open the skirt door giving access to the System
Control Module.

OPERATION

HIGH TEMPERATURE SAFETY SWITCH

High temperatures above the thermostat range
will cause the high temperature safety switch to
trip and the system to turn off.  See operating
instructions.  When water temperature is less
than 100

°

 F., reset by pressing the safety switch

reset button located on the cover of the heater
enclosure.

CAUTION:  DO NOT BREAK DOOR SEAL;

OPENING DOOR VOIDS WARRANTY

THIS EQUIPMENT REQUIRES QUALIFIED SERVICE
PERSONNEL FOR PROPER REPAIR.  CONTACT YOUR
JACUZZI WHIRLPOOL BATH DEALER FOR SERVICE.

NO USER SERVICABLE PARTS BEHIND THIS DOOR.

CAUTION

This system is GFCI (Ground Fault Circuit Interrupter) pro-tected for your
safety.  Bypassing the GFCI or tampering with the system in any way may
cause electrical shock, in-jury or death and will void the warranty.  GFCI
protection does not extend to 230 VAC circuit conversion.  If test indi-cates
that the GFCI is not functioning, DO NOT USE THE UNIT until the electrical
problem has been corrected. (See installation instructions.)  TEST THE GFCI
ONCE A MONTH.

TEST PROCEDURE
Unit must be filled to proper water level and correct power supplied.

1. Push TEST button of GFCI.
2. RESET button should pop out.  This should cut off power

to the system.  CAUTION: if RESET button does not
pop out, or if RESET button does pop out and system
is still on, DO NOT USE YOUR SPA.

3. If the GFCI tests okay, restore power by pushing in the

reset button.  The RESET button must be pushed until
it locks into place and remains depressed.

IF THE GFCI FAIL TO RESET PROPERLY, DO NOT USE
THE SPA!  CONTACT A QUALIFIED ELECTRICIAN.

FLOW

SWITCH

TEMP.

SAFETY
SWITCH

INTERLOCK

SWITCH

LIGHT #1

LIGHT #2

M

o

n

d

a

y

T

u

e

s d

a y

Wednesd

ay

T

h

u

rs

d

a

y

F

rid

a

y

Sa

tu

rd

ay

Su

nd

a

y

Turn dial to correct time and day.  Slide tabs
toward center for desired operating periods.
(One tab = 2 hrs.)

HEATER

BLOWER

JETS

MOTOR/

PUMP

FILTER

MOTOR/

PUMP

GFCI

TIMER

PLUG-IN
C0NNECTORS

FIELD WIRING BOX

(System Control Module P/N 876000

IMPORTANT:  THIS UNIT IS FACTORY WIRED FOR USE
ON 115 VAC 30 AMP (3 WIRE) CIRCUIT ONLY.

Converting the electrical system to 230 VAC requires
a 4 wire 230 VAC 50 Amp circiut breaker;  refer to the
instructions on the rear of this cover.  The conversion
s h o u l d   b e   d o n e   b y   a   q u a l i f i e d   e l e c t r i c i a n .

REFER TO N.E.C. (NATIONAL ELECTRIC CODE AND
LOCAL CODES)

115 VAC ONLY

WHIRLPOOL

BATH

R

FIELD WIRING
BOX FOR 230 VOLT
INCOMING POWER

CUIRCUIT BREAKERS

CIRCUIT
PROTECTOR
BUTTONS

TIMER

GFCI

Summary of Contents for Tirage Plus 8900000

Page 1: ...WHIRLPOOL BATH R THE TIRAGE PLUS PORTABLE WHIRLPOOL SP A OWNER S MANUAL...

Page 2: ...m See Installation Instructions to drain water away from electrical components Do not turn on power to the spa unless it is filled with water to the normal water level which is to the water level indi...

Page 3: ...___________________________________ 10 Silent Air Induction ____________________________________________________ 10 Filtration ____________________________________________________________ 10 Maintenan...

Page 4: ...t and is equipped with a ground fault circuit interrupter GFCI An optional gas heater is available as an alternate heating source and can be installed remotely The Tirage Plud is available in a wide r...

Page 5: ...p the spa over onto its bottom with the block supporting the spa 6 Remove the bolts attaching pallet to spa See Illustration D 7 Remove the pallet and carefully lower the spa to a horizontal position...

Page 6: ...ng copper connectors and must be in a separate circuit having no other appliance connected in that circuit If you do not have this kind of circuit a qualified electrician should be called in to instal...

Page 7: ...commend that you provide a concrete pad for it to rest on To do this construct forms for a 8 x 8 x 4 approx thick level pad Install a 10 gauge wire mesh 6 x 6 steel reinforced grid Attach a 8 solid co...

Page 8: ...Fill the spa with water to its normal operating level which is to the water level indicator mark on the skimmer filter frame Turn on circuit breakers at the main electrical panel Select JETS on the S...

Page 9: ...FETY SWITCH High temperatures above the thermostat range will cause the high temperature safety switch to trip and the system to turn off See operating instructions When water temperature is less than...

Page 10: ...ained at the mini mum temperature approx 50 degrees during the time period set on the timer Setting the Timer The built in 7 day timer is located in the System Control Module The tooth like tabs that...

Page 11: ...For best performance and increased equipment life pause a second or two between push button selections Not pausing may cause the switch to malfunction ACCESSORY The ACCESSORY switch controls these fun...

Page 12: ...when the heater has just turned off the indicator lamp on the control panel will turn off at this time 9 OPERATION TEMP CONTROL Turn on the heater by selecting the HTR FLTR mode with the SYSTEM switc...

Page 13: ...ever thewatertemperaturereachesthedesiredtemperature the pump will turn off For continuous filtration select FILTER on the SYS TEM switch In this mode the filter pump will run until it is manually dea...

Page 14: ...ty and water chemistry in your spa is extremely important and should be a regular part of your spa maintenance program as a neglected spa can be a breeding place for dangerous bacteria The water quali...

Page 15: ...m could be corro sive and damage your spa system Superchlorination also referred to as shock treatment The addition of an above normal level of disinfectant to kill any bacteria or algae that might ha...

Page 16: ...ols to OFF Then turn off circuit breakers at the main electrical panel Pass a garden hose through a hole in the pan and connect it to the hose bibb in the suction plumbing Turn the handle and drain th...

Page 17: ...ow the procedure outlined for winterizing your spa in a warm climate See Winterizing Note We do not recommend using this procedure if you are absent during the summer when algae build up is most likel...

Page 18: ...ace of acrylic is tough and durable and contains concentrated color This is sup ported by a substantial thickness of fiberglass rein forced polyester resin A catalyst causes a chemical reaction during...

Page 19: ...ndicator mark on skimmer filter frame C Clean strainers or skimmer baskets D Clean or replace E Open jet 1 Control Switches do not re spond A Actuated too rapidly B No power to the unit C High Tempera...

Page 20: ...ripped E GFCI tripped F Improper or defective wiring G High temperature safety switch tripped A Turn on power at service panel B Select FILTER HTR FLTR or JETS mode C Reset circuit breaker D Reset cir...

Page 21: ...reset if problem persists see Note B C D Consult electrician to correct wiring to unit E Reset button on heater after water has cooled see Note if switch continues to trip 12 Air Blower does not opera...

Page 22: ...cal plumbing codes may require the use of an anti siphon valve for such a connection Do not inter connect water supply with recirculating system of the spa To make the connections necessary to use the...

Page 23: ...product Jacuzzi Whirlpool Bath makes no representation or warranty regarding and will not be responsible for any code compliance PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE USE INSTALL...

Reviews: