CHLORINE LEVEL DIAL:
(The Desired Output dial is ignored when operation is Remotely Controlled)
Adjust the "Desired Output
%"
dial to control the amount of chlorine produced. Periodically
check the pool chlorine level and adjust the dial up or down as required.
For swimming pools, a quantity of 1-3 ppm of free available chlorine must be maintained.
For Hot tubs, a quantity of 3-5 ppm of free available chlorine must be maintained.
LCD DISPLAY: Displays salt level in ppm (parts per million).
ELECTRICAL RATINGS:
All wiring must conform to Canadian electricity code and to local NEC/CEC codes. Use copper wire
only.
PRECAUTION: Connect only to a circuit protected by a class-A ground fault interrupter.
Power: 110 to 130 V CA, 2A, 50/60Hz or 220 to 250 V CA, 1A, 50/60Hz.
Timer: Connect to load side. Remote Control unit: Connect to line power
RAINTIGHT ENCLOSURE SUITABLE FOR INDOOR OR OUTDOOR MOUNTING