background image

Installation 

(continued)

3

4) Connect T-Valve and Hoses

3) Install Mounting Plate (continued)

c)  Adjust mounting plate so length (L) between the front of the toilet 

bowl and the back of the mounting plate is as follows:

Round (EU44959):  

L=18¼" (465 mm)

Elongated (EV77959):  

L=20½"(495 mm)

d)  Tighten Mounting Bolts with screwdriver until the mounting plate is 

securely fastened to the toilet.  

NOTE: 

If your water supply line is rigid pipe, 

you may need to replace it before installing 
the Refresh Personal Hygiene System™.

a)  Install the T-Valve between the water supply line 

and the toilet tank.

b)  Place the Refresh on or beside the toilet and 

connect the Bidet Hose to the Refresh.

IMPORTANT: 

Use wrench to tighten all 

connections before continuing.  Failure to 
do so could result in flooding, leaking, or 
damage to the Refresh Personal Hygiene 
System™.  Do not overtighten!

5) Attach the Refresh

a)  Slide the Refresh onto the mounting plate.  

You will hear a “click” indicating the seat has 
been properly attached. 

 

Confirm that the seat switch is in full        
contact with the toilet bowl rim.

To Release the Refresh: 

Unplug the power plug and turn the water 
supply valve OFF.  
Push the button located on the right corner 
of the seat and gently pull.  

6) Turn ON Water & Connect Power

CAUTION: 

Use only a grounded 

15 Amp GFCI outlet!

a)  Turn the water supply valve ON slowly.  

Ensure the connections are not leaking 
before continuing.

IMPORTANT! 

Make sure work area is dry 

and hands are dry before continuing.

b)  Insert power plug into a grounded 15 Amp 

GFCI outlet.  The blue power LED on the 
Refresh Display Panel will illuminate.

IMPORTANT! 

Make sure the power plug is 

removed and the water supply is shut-off 
before removing the Refresh.

7) Battery Installation

a)  Remove battery cover from Remote Control 

and insert two (2) AAA batteries (included) 
as shown.

b)  Refasten battery cover with screw.

CAUTION: Use only a 
grounded GFCI outlet!

Press to 

Release

Water Supply Line

T-Valve

L

5

4a

4b

3c

6a

6b

Bidet Hose

7

power

power save

seat heat

seat sensor

EX93000   Refresh Installation Manual  10/06

Summary of Contents for Personal Hygiene System EV77959

Page 1: ...ant safety information Please read carefully before product installation or use Round EU44959 ROUND FRONT Elongated EV77959 ELONGATED FRONT OWNER S MANUAL Refresh Personal Hygiene System EX93000 Refresh Installation Manual 10 06 ...

Page 2: ...tric shock Use the correct voltage according to the specifications and connect to a three prong GFCI grounded outlet NOTE This GFCI outlet should be installed prior to performing this installation Do not use harsh brushes or abrasive detergents to clean the Refresh Personal Hygiene System Use only mild soap and a soft cloth for cleaning Please use caution and avoid spraying water directly on the R...

Page 3: ...sonal Hygiene System 1 Remove Toilet Seat 2 Turn OFF Water and Flush Toilet Steps may vary by type of seat a Lift hinge covers and use a screwdriver to remove the mounting bolts b Remove the toilet seat You may wish to place a container under the tank to catch any leaking that could occur during installation a Turn water valve OFF completely If the water valve does not shut OFF completely STOP Rep...

Page 4: ...ll hear a click indicating the seat has been properly attached Confirm that the seat switch is in full contact with the toilet bowl rim To Release the Refresh Unplug the power plug and turn the water supply valve OFF Push the button located on the right corner of the seat and gently pull 6 Turn ON Water Connect Power CAUTION Use only a grounded 15 Amp GFCI outlet a Turn the water supply valve ON s...

Page 5: ... instructions Troubleshooting Issue Possible Causes Solution 1 2 3 4 5 6 7 8 9 1 Clogged filter 2 Twisted hose 3 Household water pressure low 1 Nozzles are dirty 2 Clogged filter 3 Water pressure is too low 1 User not properly seated 2 Seat switch is not contacting toilet fixture properly 1 Washing time exceeding 5 minutes 2 Power failure 1 Clean filter 2 Straighten hose 3 Increase water pressure ...

Page 6: ...e are four 4 temperature levels low medium high off Each wider bar on the LCD graphic display represents one level increase No LCD graphic indicates seat heating is OFF AdjustingWaterTemperature PressWATERTEMP button to adjust temperature Repeat until desired level is achieved There are four 4 temperature levels low medium high off Each wider bar on the LCD graphic display represents one level inc...

Page 7: ...esh while it is in Power save mode returns the unit to normal operation The Refresh will not re enter the Power save mode until the next day s scheduled start time a Press and hold the STOP button on the remote Control for over 5 seconds until the Clock flashes b Use the button to set the HOUR and the button to set the MINUTES There are two 2 buttons on the rear right corner of the Refresh for use...

Page 8: ... Refresh bidet seat For a more thorough cleaning you may remove the Refresh bidet seat To release push the button located on the back right side of the seat and pull the Refresh bidet seat forward It is recommended that you clean the retractable nozzles monthly or as necessary To clean the nozzles pull them out gently and use a soft damp brush or cloth to wipe down DO NOT use soap or detergents to...