background image

ENGLISH

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC

SHOCK, OR INJURY TO PERSONS

WARNING — WHEN USING THIS UNIT, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED,
INCLUDING THE FOLLOWING:

DANGER: 

 

TO REDUCE THE RISK OF INJURY, DO NOT PERMIT CHILDREN TO USE THIS UNIT

UNLESS THEY ARE CLOSELY SUPERVISED AT ALL TIMES.

WARNING — 

USE THIS UNIT ONLY FOR ITS INTENDED USE AS DESCRIBED IN THIS MANUAL.  DO

NOT USE ATTACHMENTS NOT RECOMMENDED BY THE MANUFACTURER.

WARNING — 

NEVER DROP OR INSERT ANY OBJECT INTO ANY OPENING.

WARNING — 

DO NOT OPERATE THIS UNIT WITHOUT THE GUARD OVER THE SUCTION FITTING.

WARNING — 

THIS UNIT MUST BE CONNECTED ONLY TO A SUPPLY CIRCUIT THAT IS PROTECTED

BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI).  SUCH A GFCI SHOULD BE PROVIDED BY
THE INSTALLER AND SHOULD BE TESTED ON A ROUTINE BASIS.  TO TEST THE GFCI, PUSH THE
TEST BUTTON.  THE GFCI SHOULD INTERRUPT POWER.  PUSH THE RESET BUTTON.  POWER
SHOULD BE RESTORED.  IF THE GFCI FAILS TO OPERATE IN THIS MANNER, THE GFCI IS
DEFECTIVE.  IF THE GFCI INTERRUPTS POWER TO THE BATHTUB WITHOUT THE TEST BUTTON
BEING PUSHED, A GROUND CURRENT FLOWING, INDICATING A POSSIBILITY OF AN ELECTRIC
SHOCK.  DO NOT USE THIS HYDROMASSAGE BATHTUB.  DISCONNECT THE HYDROMASSAGE
BATHTUB AND HAVE THE PROBLEM CORRECTED BY A QUALIFIED SERVICE REPRESENTATIVE
BEFORE USING.

WARNING — 

(FOR PERMANENTLY CONNECTED UNITS) A GREEN COLORED TERMINAL (OR A WIRE

CONNECTOR MARKED “G”, “GR”, “GROUND”, OR “GROUNDING”) IS PROVIDED WITHIN THE TERMINAL
COMPARTMENT.  TO REDUCE THE RISK OF ELECTRIC SHOCK, CONNECT THE TERMINAL OR
CONNECTOR TO THE GROUNDING TERMINAL OF YOUR ELECTRIC SERVICE OR SUPPLY PANEL WITH
A CONDUCTOR EQUIVALENT IN SIZE TO THE CIRCUIT CONDUCTORS SUPPLYING THIS EQUIPMENT.

OPERATING

WARNING — 

PROLONGED IMMERSION IN HOT WATER MAY INDUCE HYPERTHERMIA.  HYPER-

THERMIA OCCURS WHEN THE INTERNAL TEMPERATURE OF THE BODY REACHES A LEVEL SEV-
ERAL DEGREES ABOVE THE NORMAL BODY TEMPERATURE OF 98.6°F.  THE SYMPTOMS OF
HYPERTHERMIA INCLUDE AN INCREASE IN THE INTERNAL TEMPERATURE OF THE BODY, DIZZI-
NESS, LETHARGY, DROWSINESS AND FAINTING.  THE EFFECTS OF HYPERTHERMIA INCLUDE:

A)  FAILURE TO PERCEIVE HEAT
B)  FAILURE TO RECOGNIZE THE NEED TO EXIT THE SPA OR HOT TUB,
C)  UNAWARENESS OF IMPENDING HAZARD,
D)  FETAL DAMAGE IN PREGNANT WOMEN,
E)  PHYSICAL INABILITY TO EXIT THE SPA OR HOT TUB, AND
F)  UNCONSCIOUSNESS RESULTING IN DANGER OF DROWNING.

WARNING — 

THE USE OF ALCOHOL, DRUGS OR MEDICATION CAN GREATLY INCREASE THE

RISK OF FATAL HYPERTHERMIA.

WARNING — 

DO NOT TAMPER WITH USER-OPERATED CONTROLS OR SUCH DEVICES.

2

Jacuzzi Whirlpool Bath   K339000X   3/06

Summary of Contents for Luxury/Designer Bath Series K339000X

Page 1: ...uct registration card provided with your unit Write and save the model and serial number of your unit below Date Purchased ____________________________________________________________ Purchased From _...

Page 2: ...N ELECTRIC SHOCK DO NOT USE THIS HYDROMASSAGE BATHTUB DISCONNECT THE HYDROMASSAGE BATHTUB AND HAVE THE PROBLEM CORRECTED BY A QUALIFIED SERVICE REPRESENTATIVE BEFORE USING WARNING FOR PERMANENTLY CONN...

Page 3: ...BY THE MANUFACTURERS WARNING TOAVOIDINJURY EXERCISECAUTIONWHENENTERINGOREXITINGTHEHYDROMASSAGEBATHTUB WARNING KEEP BODY AND HAIR A MINIMUM OF 6 15 2 cm AWAY FROM SUCTION FITTING AT ALL TIMES WHEN THE...

Page 4: ...______ 19 Clean Up After Installation _______________________________________________________________ 19 Operating Instructions __________________________________________________________________ 20 22...

Page 5: ...he carrier For definitions of warranty coverage and limitations refer to the published warranty information packed with the product All bath units are factory tested for proper operation and watertigh...

Page 6: ...ed P N P187000 16 1 4 413 mm A 13 1 2 343 mm B Factory Installed Intake S749000 Heater Factory Installed Intake S749000 Heater Factory Installed Intake S749000 Heater Factory Installed Intake S749000...

Page 7: ...otected separate circuit SPECIFICATIONS DUETTA 7242 RH 72 1829 mm L 42 1067 mm W 26 660 mm H Template Provided P N DA06000 Not Available Factory Installed Intake S749000 Heater Min 98 U S gal 371 lite...

Page 8: ...are nominal with a tolerance of 0 and 1 4 6 4 mm W H BELLAVISTA CORNER Right Hand SIDE VIEW END VIEW 2 51 mm Heater MAX 1 2 FOR ALL UNITS Electrical Service Requirements All require a dedicated GFCI p...

Page 9: ...Access Opt Service Access BELLAVISTA 5 5 Right Hand 4 x 4 42 72 10 1 2 35 13 16 11 3 4 6 30 1 8 Heater Motor 12 H x 18 L Service Access Opt Service Access BELLAVISTA 6 Right Hand CIPREA Right Hand 4...

Page 10: ...4 mm 10 Jacuzzi Whirlpool Bath K339000X 3 06 ROUGHING IN REFERENCE ELARA 6042 Right Hand 60 42 21 4 2 10 6 12 x 4 2 Heater Motor Opt Service Access 12 H x 18 L Service Access ELARA 6636 Right Hand 66...

Page 11: ...REFERENCE RECTANGULAR Some tubs are supplied with cutout and or undermount template Refer to CUTOUT on pages 6 8 for template part numbers Add 1 4 to this dimension when roughing in for 3 wall niche N...

Page 12: ...1 4 6 4 mm ROUGHING IN REFERENCE VENICIA Right Hand 10 1 2 36 3 42 72 12 1 8 5 1 4 29 7 8 18 x 4 Motor 12 H x 18 L Service Access Heater Opt Service Access 12 H x 18 L Service Access Opt Service Acce...

Page 13: ...ments are in inches To convert to millimeters multiply inches by 25 4 3 Service access dimensions given are minimum size 4 The overall dimensions are nominal with a tolerance of 0 and 1 4 6 4 mm 60 60...

Page 14: ...anchoring material is NOT used use construction adhesive under the foam feet and fasten the metal anchor straps to the floor to prevent the unit from shifting while trim deck finishes or finish caulk...

Page 15: ...THOUT SKIRT 12 12 FRONT HEATER Service Access Corner Tubs For partially or fully sunken installations allow for ac cess to service connections It is the installer s respon sibility to provide sufficie...

Page 16: ...e enough space to maneuver and insert tub The Designer Luxury line whirlpool tubs have electrical plumbing and lighting systems installed Do not lift the bath by the plumbing or wiring at any time han...

Page 17: ...in the bottom illustration Do not use plumbing fixtures or plumbing lines to lower unit The clearance under the substrate is required for air flow circulation requirements Place a piece of scrap lumbe...

Page 18: ...nfirm you have 120 VAC 20 AMP and 15 AMP service requirements The GFCI circuits must match these requirements Care must be taken to connect the 20 AMP pump motor or control box power cord ONLY to the...

Page 19: ...ontrol the direction of the spray NOTE Proper installation of a shower is the responsibil ity of the installer Jacuzzi Whirlpool Bath is not respon sible for damage to the unit or for water damage whi...

Page 20: ...ly Baths equipped with 2 speed motors and electronic controls can also influence water force and force of air Direction To change the direction of the water flow swivel the jet nozzle to the desired a...

Page 21: ...om no air to maximum air Left Air Valve Status LED The Left Air Valve Status LED will show four LED lights at maximum air and only one LED light when the air is turned OFF Each additional LED indicate...

Page 22: ...through the whirlpool system High Limit Switch The heater includes an exclusive High Limit switch This safety circuit will not false trip from hot tap water It will only turn off the heater if the th...

Page 23: ...er and run for 2 to 3 minutes Drain completely and rinse off any residue Remember to reset the air valves to your bathing comfort level DANGER Harmful if swallowed Eye irritant Protect your eyes skin...

Page 24: ...st always be in place on the suction fitting to minimize the potential hazard of hair and or body en trapment NOTCH GASKET COVER STRAINER SCREW SUCTION FITTING SUCTION COVER STRAINER ASSEMBLY Lighting...

Page 25: ...junction box With motor turned off remove safety cover and remove any debris Clean thoroughly before replacing Replace suction cover before operating Use electronic controls to open air valves Reset...

Page 26: ...2008 by Jacuzzi Whirlpool Bath Products Page of 2 Publication GR86000A 08 08 8 Button Control Panel SPECIFICATIONS FOR ALL UNITS Electrical Service Requirements Requires a separate dedicated GFCI prot...

Page 27: ...rom the left side to the right side next to the pump motor The following details will replace information found in the Combination Air Bath and Whirlpool Installation and Operation Instructions BR2800...

Page 28: ...n the wall of the bath near the pump motor Non jetted baths The label is located next to the overflow MODEL XXXXXXX NAME XXXXX COLOR XXXXX MFG XXXXX SER XXXXXX MADE IN USA THIS PRODUCT MEETS OR EXCEED...

Page 29: ...as lightning floods earthquakes etc In addition THE COMPANY WILL NOT BE RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES or losses arising from any cause e g water damage to carpet ceiling loss of...

Page 30: ...rum Dr Suite 400 Dallas TX 75254 Call 800 288 4002 To obtain warranty replacement for factory installed components for Company supplied options and accessories manufactured and supplied by the Company...

Reviews: