46
A3 Checking Voltages to Devices
Device voltages are often measured at the circuit board to determine whether the board or device is bad. If the
circuit board delivers voltage when device operation is called, the circuit board is probably good and the prob-
lem lies with the device or the wiring to the device. The following voltage chart shows operating voltages for
all major hot tub components. Voltage is considered good if within ±10% of the listed value. Refer to appendix
pages 50-53 for your specific circuit boards test point locations.
For all North American 60 Hz
J-LX/J-LXL
2011-2013 J-335/J-345/J-355/J-365/J-375 Models
Device
Test Points
Voltage ±10%
Pump 1 (Low Speed)
5 and 6
240 VAC
Pump 1 (High Speed)
5 and 7
240 VAC
Pump 2 (High Speed)
8 and 9
240 VAC
Circulation pump
14 and 15
240 VAC
Water heater
12 and 13
240 VAC
CLEAR
RAY
or Ozone generator (optional)
16 and 17
240 VAC
2011-2013 J-315/J-325 Models
Device
Test Points
Voltage ±10%
Pump 1 (Low Speed)
5 and 6
240 VAC
Pump 1 (High Speed)
5 and 7
240 VAC
Circulation pump
14 and 15
240 VAC
Water heater
12 and 13
240 VAC
CLEAR
RAY
or Ozone generator (optional)
16 and 17
240 VAC
2011-2012 J-230/J-270/J-280 Models with Circulation Pump
Device
Test Points
Voltage ±10%
Pump 1 (Low Speed)
5 and 6
240 VAC
Pump 1 (High Speed)
5 and 7
240 VAC
Pump 2
(N/A on J-230)
8 and 9
240 VAC
Circulation pump
14 and 15
240 VAC
Water heater
12 and 13
240 VAC
CLEAR
RAY
or Ozone generator (optional)
16 and 17
240 VAC
J-210 Models
2011-2013 J-315/J-325 Models
Device
Test Points
Voltage ±10%
Pump 1 (Low Speed)
5 and 6
120 VAC
Pump 1 (High Speed)
5 and 7
120 VAC
Water heater
12 and 13
120 VAC or 240 VAC*
CLEAR
RAY
or Ozone generator (optional)
16 and 17
120 VAC
*Depends whether hot tub is connected to 120 VAC or 240 VAC supply
J-230/J-235/J-245/J-270/J-275/J-280 Models without Circulation Pump Models
Device
Test Points
Voltage ±10%
Pump 1 (Low Speed)
5 and 6
240 VAC
Pump 1 (High Speed)
5 and 7
240 VAC
Pump 2
(N/A on J-230)
8 and 9
240 VAC
Water heater
12 and 13
240 VAC
CLEAR
RAY
or Ozone generator (optional)
16 and 17
240 VAC