J-200 Series
6.0 Power Requirements
Jacuzzi® spas are designed to provide optimum performance and flexibility
of use when connected to the maximum electrical service listed below. Minor
circuit board modifications can be performed to allow your new spa to accept an
electrical service other than the factory operation setting.
Note: Refer to pages
for circuit board configuration details or contact your authorized Jacuzzi
dealer.
All North American J-270 & J-280 Models (60Hz)
240V/40A*
240V/50A**
240V/60A***
Circuit Breaker (2-Pole):
40A
*
50A
**
60A
***
Number of Wires:
3
3
3
Frequency:
60Hz
60Hz
60Hz
Current Draw:
26A
36A
45A
*
In 40A configuration, the heater
will not operate
while either jets pump
is running in high speed.
Note: pump 2 runs only in high speed.
**
In 50A configuration, the heater
will not operate
while both jets pumps
are running in high speed.
This is the factory setting.
Note: pump 2 runs
only in high speed.
***
In 60A configuration the heater
will operate
while both jets pumps are
running in high speed.
All North America J-230 Models (60Hz)
240V/40A*
240V/50A**
Circuit Breaker (2-Pole):
40A
*
50A
**
Number of Wires:
3
3
Frequency:
60Hz
60Hz
Current Draw:
26A
36A
*
In 40A configuration, the heater
will not operate
while either jets pump
is running in high speed.
Note: pump 2 runs only in high speed.
**
In 50A configuration, the heater
will not operate
while both jets pumps
are running in high speed.
This is the factory setting.
Note: pump 2 runs
only in high speed.
10