Jets Button
Press the ‘Jets' button once to turn the Pump on/off.
Circulation Pump Model
:
If fitted with a 24 hour
Circulation Pump, The Circulation Pump runs
continuously with the exception of shutting off for 30
minutes at a time in hot environments.
2 speed Pump:
Press the ‘Jets' button once to shift
between low and high speed if it is a 2 Speed Pump.
Press ‘Jets' button once for low speed, twice for high
speed. If left running, the Pump will turn off after
15 minutes. Low speed automatically turns on during filter
cycle, low speed cannot be de-activated during filter cycle,
but high speed may be utilised.
Light
Press the
button to turn the Spa Light on/off.
If left on,
the Light automatically turns off after 4
hours.
Blower
The ‘Blower' button turns the Blower on/off. The Blower
automatically turns off after 15 minutes.
temperature Adjustment
Press the ‘Temp' button once to display the set
temperature. To change the set temperature, press the
‘Temp' pad a second time before the LCD stops flashing.
Each press of the ‘Temp' button will continue to either
raise or lower the set temperature.
If the opposite direction is desired, release the pad and let
the display revert to the current water temperature. Press
the ‘Temp' pad to display the set temperature, and again
to make the temperature change in the desired direction.
After 3 seconds the LCD will automatically
display the last measured Spa temperature.
settInG stAnDARD/eConoMY & sLeeP MoDe
1. PRESS TEMP BUTTON and then
2. PRESS LIGHT BUTTON.
Display will read either ‘St' (Standard), ‘Ec' (Economy)
or SL (Sleep) Mode. Repeat steps 1 and 2 until desired
mode is reached.
Display will flash alternatively from Temperature to
Mode. Standard Mode will show Temperature only.
standard
Mode is programmed to maintain the desired
temperature (heating on demand). Note that the last
measured Spa temperature displayed is current only
when the Pump has been running for at least 2 minutes.
‘St' will be displayed momentarily when you switch into
Standard Mode.
economy
Mode is programmed to heat the Spa to
the set temperature only during ‘F' (Filtration) cycles.
‘Ec' will display solid when temperature is not current,
and will alternate with temperature when temperature
is current.
sleep
Mode heats the Spa to within approx 11
o
C of
the set temperature, only during ‘F' (Filtration) cycles.
‘SL' will display solid when temperature is not current,
and will alternate with temperature when temperature
is current.
BALBoA sCs 501
oPeRAtInG PRoCeDuRe
InItIAL stARt-uP
When your Spa is first powered up, it will go into a Priming Mode, indicated by ‘
' on the LCD readout.
The Priming Mode will last for less than 4 minutes and then the Spa will begin normal
operation. The Heater
Light will flicker when Priming, or when the system is self testing.
DeFAuLt PRe-set
The default pre-set temperature has a setting of 37
o
C in Standard Mode, with a setting of ‘F2'.
Circulation Pump Models
2 speed Pump Models
Temp
Light
Blower