background image

ENGLISH

 OVAL & ROUND BATHS

DRAIN/OVERFLOW

A

B

MODEL

PRODUCT

WEIGHT

OPERATING

GALLONAGE

TOTAL WEIGHT/

FLOOR LOADING

DIMENSIONS

DRAIN/OVERFLOW

DIMENSIONS

SKIRT &

MOUNTING

CUTOUT

CORTINA™

RH

VENICIA™

RH

72"

(1829 mm) L

72"

(1829 mm) W

22-1/4" (  565 mm) H

1293 lb

(588 kg)/

36 lb/ft

2

(176 kg/m

)

100 U.S. gal

(379 liters)

210 lb

(95 kg)

72"  (1829 mm) L
42"  (1067 mm) W
23"  (  584 mm) H

1130 lb

(514 kg)/

54 lb/ft

2

(263 kg/m

)

90 U.S. gal

(341 liters)

130 lb

(59 kg)

20"       (508 mm) A
14"       (356 mm) B

SPECIFICATIONS 

(Oval & Round) LH =  Left Hand, RH = Right Hand

70" Dia.

(1778 mm)

Hole

Template

Provided

P/N

P187000

Not Available

Not Available

Factory Installed

Discharge

(U394000 HEATER)

16-3/4"  (426 mm) A
19-1/4"  (489 mm) B

NOTE:

  The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4

mm).

Factory Installed

Intake

(S749000 Heater)

7

Jacuzzi Whirlpool Bath   K339000X   3/06

HEATER,

INTAKE/DISCHARGE

FOR ALL UNITS: 

Electrical Service Requirements

 All require a dedicated GFCI protected separate circuit.

RapidHeat

TM

: 120 VAC, 15 AMP, 60 Hz. dedicated GFCI protected separate circuit.

Motor/Pump: 120 VAC, 20 AMP, 60 Hz. dedicated GFCI protected separate circuit.

SPECIFICATIONS

DUETTA™
7242

RH

72"  (1829 mm) L
42"  (1067 mm) W
26"  (  660 mm) H

Template

Provided

P/N

DA06000

Not Available

Factory Installed

Intake

(S749000 Heater)

Min - 98 U.S. gal

(371 liters)

Max - 106 U.S. gal

(401 liters)

130 lb

(59 kg)

1277 lb

(581 kg)/

60.8 lb/ft

2

(296 kg/m

)

18.4"     (467 mm) A
11"       (279 mm) B

(Motor)

(Heater)

CORTINA™

L

W

END VIEW

H

W

SIDE VIEW 

1/2"

DUETTA™ 

(13 mm)

(Motor)

(Heater)

MAX. 2-1/2"

DUETTA™
6042

RH

60”  (1524 mm) L
42”  (1067 mm) W
26”  (  660 mm) H

Template

Provided

P/N

DA09000

Not Available

Factory Installed

Intake

(S749000 Heater)

Min - 77 U.S. gal

(291 liters)

Max - 83 U.S. gal

(314 liters)

110 lb

(50 kg)

999 lb

(454 kg)/

57.1 lb/ft

2

(278 kg/m

2

 )

18.4"     (467 mm) A
11"       (279 mm) B

DUETTA™
6636

RH

66”  (1676 mm) L
36”  (914 mm) W
26”  (  660 mm) H

Template

Provided

P/N

DA08000

Not Available

Factory Installed

Intake

(S749000 Heater)

Min - 75 U.S. gal

(284 liters)

Max - 80 U.S. gal

(303 liters)

180 lb

(82 kg)

1019 lb

(463 kg)/

61.8 lb/ft

2

(301 kg/m

2

 )

18.4"     (467 mm) A
11"       (279 mm) B

DUETTA™
6642

RH

66”    (1676 mm) L
42”    (1067 mm) W
26”      (660 mm) H

Template

Provided

P/N

DA07000

Not Available

Factory Installed

Intake

(S749000 Heater)

Min - 90 U.S. gal

(341 liters)

Max - 95 U.S. gal

(360 liters)

117 lb

(53 kg)

1106 lb

(503 kg)/

57.5 lb/

ft

2

(280 kg/m

2

 )

18.4"     (467 mm) A
11"       (279 mm) B

END VIEW 

SIDE VIEW 

2"

(Motor)

(Heater)

(51 mm)

VENICIA™ 

MAX. 1/2"

Summary of Contents for CIPREA

Page 1: ...duct registration card provided with your unit Write and save the model and serial number of your unit below Date Purchased ____________________________________________________________ Purchased From ____________________________________________________________ Installed By ________________________________________________________________ Serial Number _______________________________________________...

Page 2: ...AN ELECTRIC SHOCK DO NOT USE THIS HYDROMASSAGE BATHTUB DISCONNECT THE HYDROMASSAGE BATHTUB AND HAVE THE PROBLEM CORRECTED BY A QUALIFIED SERVICE REPRESENTATIVE BEFORE USING WARNING FOR PERMANENTLY CONNECTED UNITS A GREEN COLORED TERMINAL OR A WIRE CONNECTOR MARKED G GR GROUND OR GROUNDING IS PROVIDED WITHIN THE TERMINAL COMPARTMENT TO REDUCE THE RISK OF ELECTRIC SHOCK CONNECT THE TERMINAL OR CONNE...

Page 3: ... BY THE MANUFACTURERS WARNING TOAVOIDINJURY EXERCISECAUTIONWHENENTERINGOREXITINGTHEHYDROMASSAGEBATHTUB WARNING KEEP BODY AND HAIR A MINIMUM OF 6 15 2 cm AWAY FROM SUCTION FITTING AT ALL TIMES WHEN THE HYDROMASSAGE SYSTEM IS OPERATING HAIR LONGER THAN SHOULDER LENGTH SHOULD BE SECURED CLOSE TO THE HEAD WARNING RISK OF ELECTRICAL SHOCK DO NOT PERMIT ELECTRICAL APPLIANCES SUCH AS HAIR DRYER LAMP TELE...

Page 4: ..._______ 19 Clean Up After Installation _______________________________________________________________ 19 Operating Instructions __________________________________________________________________ 20 22 Maintenance Instructions ________________________________________________________________ 23 24 General Troubleshooting Guide ___________________________________________________________ 25 Authorize...

Page 5: ...the carrier For definitions of warranty coverage and limitations refer to the published warranty information packed with the product All bath units are factory tested for proper operation and watertight connections prior to shipping NOTE Prior to installation the bath must be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling Jacuzzi Whirlp...

Page 6: ...ded P N P187000 16 1 4 413 mm A 13 1 2 343 mm B Factory Installed Intake S749000 Heater Factory Installed Intake S749000 Heater Factory Installed Intake S749000 Heater Factory Installed Intake S749000 Heater Factory Installed Intake S749000 Heater Factory Installed Intake S749000 Heater Factory Installed Intake S749000 Heater ALLUSION 7242 RH ALLUSION 6636 RH ALLUSION 7236 RH 72 1829 mm L 42 1067 ...

Page 7: ...rotected separate circuit SPECIFICATIONS DUETTA 7242 RH 72 1829 mm L 42 1067 mm W 26 660 mm H Template Provided P N DA06000 Not Available Factory Installed Intake S749000 Heater Min 98 U S gal 371 liters Max 106 U S gal 401 liters 130 lb 59 kg 1277 lb 581 kg 60 8 lb ft2 296 kg m2 18 4 467 mm A 11 279 mm B Motor Heater CORTINA L W END VIEW H W SIDE VIEW L 1 2 DUETTA 13 mm Motor Heater MAX 2 1 2 DUE...

Page 8: ... are nominal with a tolerance of 0 and 1 4 6 4 mm W H BELLAVISTA CORNER Right Hand SIDE VIEW END VIEW 2 51 mm Heater MAX 1 2 FOR ALL UNITS Electrical Service Requirements All require a dedicated GFCI protected separate circuit RapidHeatTM 120 VAC 15 AMP 60 Hz dedicated GFCI protected separate circuit Motor Pump 120 VAC 20 AMP 60 Hz dedicated GFCI protected separate circuit PRODUCT WEIGHT OPERATING...

Page 9: ...e Access Opt Service Access BELLAVISTA 5 5 Right Hand 4 x 4 42 72 10 1 2 35 13 16 11 3 4 6 30 1 8 Heater Motor 12 H x 18 L Service Access Opt Service Access BELLAVISTA 6 Right Hand CIPREA Right Hand 4 7 14 x 4 72 34 1 2 48 36 Motor Heater 12 H x 18 L Service Access 7 32 1 2 11 3 4 6 30 1 8 42 60 4 x 4 Heater Motor 12 H x 18 L Service Access Opt Service Access BELLAVISTA 5 Right Hand 66 36 11 15 16...

Page 10: ... 4 mm 10 Jacuzzi Whirlpool Bath K339000X 3 06 ROUGHING IN REFERENCE ELARA 6042 Right Hand 60 42 21 4 2 10 6 12 x 4 2 Heater Motor Opt Service Access 12 H x 18 L Service Access ELARA 6636 Right Hand 66 36 18 4 2 10 6 12 x 4 Motor Opt Service Access 12 H x 18 L Service Access Heater 2 ELARA 6636 Right Hand 66 36 18 4 2 10 6 12 x 4 Motor Opt Service Access 12 H x 18 L Service Access Heater 2 72 42 21...

Page 11: ... REFERENCE RECTANGULAR Some tubs are supplied with cutout and or undermount template Refer to CUTOUT on pages 6 8 for template part numbers Add 1 4 to this dimension when roughing in for 3 wall niche NOTE 1 Measurements inside each unit represent cutout in floor to allow for drain overflow 2 All measurements are in inches To convert to millimeters multiply inches by 25 4 3 Service access dimension...

Page 12: ...d 1 4 6 4 mm ROUGHING IN REFERENCE VENICIA Right Hand 10 1 2 36 3 42 72 12 1 8 5 1 4 29 7 8 18 x 4 Motor 12 H x 18 L Service Access Heater Opt Service Access 12 H x 18 L Service Access Opt Service Access 72 42 36 11 3 1 2 14 x 4 DUETTA 7242 Right Hand Motor Heater 2 12 Jacuzzi Whirlpool Bath K339000X 3 06 11 04 60 42 30 3 84 DUETTA 6042 Right Hand 13 x 4 2 Motor Heater 12 H x 18 L Service Access O...

Page 13: ...ements are in inches To convert to millimeters multiply inches by 25 4 3 Service access dimensions given are minimum size 4 The overall dimensions are nominal with a tolerance of 0 and 1 4 6 4 mm 60 60 77 3 4 3 7 1 2 34 9 16 59 1 2 BELLAVISTA CORNER Right Hand Ref Motor Service Access Opt Service Access Heater 12 x4 72 72 5 16 4 26 16 9 14 x5 Motor 12 H x 18 L Service Access Heater CORTINA Right H...

Page 14: ...r anchoring material is NOT used use construction adhesive under the foam feet and fasten the metal anchor straps to the floor to prevent the unit from shifting while trim deck finishes or finish caulking cure The rim of the bath is not designed to support weight If finish material is to overlap or contact the bath the added weight must be fully self supporting The protective film liner inside the...

Page 15: ...ITHOUT SKIRT 12 12 FRONT HEATER Service Access Corner Tubs For partially or fully sunken installations allow for ac cess to service connections It is the installer s respon sibility to provide sufficient service access The recom mended minimum dimensions allowable for service to the bath are shown in the Service Access illustration Provide adequate area around unit for air circulation for cooling ...

Page 16: ...ve enough space to maneuver and insert tub The Designer Luxury line whirlpool tubs have electrical plumbing and lighting systems installed Do not lift the bath by the plumbing or wiring at any time handle by the shell only TWO WALLINSTALLATION THREE WALLINSTALLATION TUB CUTOUT TUB CUTOUT TUB CUTOUT TUB CUTOUT MINIMUM VERTICALCLEARANCE FOR INSTALLER TO POSITION TUB 48 32 32 3 3 32 32 32 3 10 10 ...

Page 17: ... in the bottom illustration Do not use plumbing fixtures or plumbing lines to lower unit The clearance under the substrate is required for air flow circulation requirements Place a piece of scrap lumber under each corner as a temporary support for the tub rim Inspect all fittings plumbing and control lines after inserting to insure components are not damaged disconnected or contacting the finish s...

Page 18: ...onfirm you have 120 VAC 20 AMP and 15 AMP service requirements The GFCI circuits must match these requirements Care must be taken to connect the 20 AMP pump motor or control box power cord ONLY to the 20 AMP GFCI circuit and to connect the 15 AMP heater power cord ONLY to the 15 AMP GFCI circuit Do NOT switch power cords and GFCI circuits With a 8 solid copper wire bond the heater to the house ele...

Page 19: ...control the direction of the spray NOTE Proper installation of a shower is the responsibil ity of the installer Jacuzzi Whirlpool Bath is not respon sible for damage to the unit or for water damage which might occur due to its installation Anti Siphon Valve Optional Anti Siphon valve installation Anti Siphon valve is not supplied with the tub Consult your local plumbing code requirements for the m...

Page 20: ...nly Baths equipped with 2 speed motors and electronic controls can also influence water force and force of air Direction To change the direction of the water flow swivel the jet nozzle to the desired angle The jets can be directed individually toward any location on your body to provide a hydromassage The jets can also be adjusted so that they all point in the same direction clockwise or countercl...

Page 21: ...rom no air to maximum air Left Air Valve Status LED The Left Air Valve Status LED will show four LED lights at maximum air and only one LED light when the air is turned OFF Each additional LED indicates more air flow Right Air Valve Switch Pressing this button will acitvate the right air valves Use the Toggle buttons to increase decrease air flow to the right set of jets The air flow can be adjust...

Page 22: ...g through the whirlpool system High Limit Switch The heater includes an exclusive High Limit switch This safety circuit will not false trip from hot tap water It will only turn off the heater if the thermostat fails To reset press the button If the high limit trips frequently contact your Authorized Electrical Mechanical Service Provider Visit our web site at http www jacuzzi com To find service a...

Page 23: ...ter and run for 2 to 3 minutes Drain completely and rinse off any residue Remember to reset the air valves to your bathing comfort level DANGER Harmful if swallowed Eye irritant Protect your eyes skin and mucus membranes from contact with this product or its concentrated solution A strong alkaline product can cause severe burns to the eyes and skin If you have followed the standard purging instruc...

Page 24: ...ust always be in place on the suction fitting to minimize the potential hazard of hair and or body en trapment NOTCH GASKET COVER STRAINER SCREW SUCTION FITTING SUCTION COVER STRAINER ASSEMBLY Lighting Chromotherapy lighting Your unit has Chromotherapy LED lighting If the lights fail to function contact your Jacuzzi Whirlpool Bath dealer There are no customer serviceable components on the Chro mot...

Page 25: ...r junction box With motor turned off remove safety cover and remove any debris Clean thoroughly before replacing Replace suction cover before operating Use electronic controls to open air valves Reset air valves to allow air flow Untighten unions check and reseat O ring If O ring has been pinched out of shape replace refer to number below When tightening union nuts hand tighten only Let motor cool...

Page 26: ... 2008 by Jacuzzi Whirlpool Bath Products Page of 2 Publication GR86000A 08 08 8 Button Control Panel SPECIFICATIONS FOR ALL UNITS Electrical Service Requirements Requires a separate dedicated GFCI protected circuit Blower 120 VAC 15 Amp 60 Hz separate dedicated GFCI protected circuit Motor Pump 240 VAC 15 Amp 60 Hz separate dedicated GFCI protected circuit RapidHeat 120 VAC 15 Amp 60 Hz separate d...

Page 27: ...from the left side to the right side next to the pump motor The following details will replace information found in the Combination Air Bath and Whirlpool Installation and Operation Instructions BR28000B 4 05 manual NOTE The following art replaces the similar art found on Page 1 of the Combination Air Bath and Whirlpool manual NOTE The following art replaces both pieces of similar art at the botto...

Page 28: ...on the wall of the bath near the pump motor Non jetted baths The label is located next to the overflow MODEL XXXXXXX NAME XXXXX COLOR XXXXX MFG XXXXX SER XXXXXX MADE IN USA THIS PRODUCT MEETS OR EXCEED THE FOLLOWING STANDARDS BATH SPA xxxx xxxx x SHOWER BASES xxxx xxxx x SPECIFICATION SERIAL NUMBER PLATE YOU WILL FIND YOUR SERIAL NUMBER HERE XXXX XXXXXX Applicable Electrical Specifications for you...

Page 29: ... as lightning floods earthquakes etc In addition THE COMPANY WILL NOT BE RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES or losses arising from any cause e g water damage to carpet ceiling loss of use etc including its own negligence damages to respecting or resulting from plated parts when pool and or spa chemicals are used in the unit optional bath equipment not manufactured by the Company b...

Page 30: ...orum Dr Suite 400 Dallas TX 75254 Call 800 288 4002 To obtain warranty replacement for factory installed components for Company supplied options and accessories manufactured and supplied by the Company call or write the above Provide a description of the problem and proof of purchase You will be instructed how to obtain replacements and where to return at your expense the failed component s option...

Reviews: