background image

 

 

 

 

Proper Operation, Care & Maintenance 

 

 

 

Before any maintenance or cleaning, disconnect the Power Blade Charger from the AC wall outlet. 

 
 

 

 

 

 

 

 

 

 

 

 

JACO products are designed and manufactured to provide years of operation.  Take care to use the product 

as intended and keep clean for best overall performance. 

 
 

Most of the surfaces of your JACO product are finished using a durable, antimicrobial powder coat finish.  It 

is recommended that the surface areas that are in contact with day to day use be cleaned regularly.  Always 

review the cleaning products that are being used and verify that it is safe to use on the powder coat finish.  

In general, a solution or wipe that is no more than 10% bleach, such as most germicidal wipes used in 

hospitals, will be acceptable but it is recommended that you consult with JACO Customer Service if you are 

not sure it is safe to use. 

 
 
 
 
 
  
 

Your JACO Mobile Cart does not require any scheduled maintenance however it is good practice to clean the 

casters and check that the Cart height adjustment is operating correctly at least once a year.  Please contact 

JACO Customer Service as needed for more information in maintaining your JACO Mobile Carts. 

 
 

 
 

It is recommended that the Power Blade Charger be located in a clean environment free of liquids, dirt and 

dust and a max room temperature of 77 deg (25 C).  The Power Blade Charger should be reviewed weekly 

for proper care and cleaning.  The bays should be used only for the charging of the JACO Power Blade 

Battery Packs, any other use may cause damage and will void the warranty. 

 
 

  
 

When cleaning the outside of the Cart Controller, Power Blade Battery Pack or 

Power Blade Charger, a dry cloth will be effective for removing dust or light dirt.  

If needed, a standard hospital grade germicidal wipe can be used.  It is 

recommended that the wipe contain no more than 10% bleach to prevent 

possible damage to the powder coat metal surfaces. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inspect the inside bays of the Cart Controller and Power Blade Charger as needed or weekly, remove the 

Power Blade Battery Packs to inspect the connections.  Remove material that may have accidently dropped 

into the Power Blade Charger or Cart Controller.  

 
 

 
 

There should be no reason to clean the inside bay area but if required, make sure the Power Blade Charger 

unit is unplugged and a damp (not saturated), less than 10% bleach wipe is used, allow ample drying time. 

 

 

 
 

If the inside connectors pins do become dirty, do not insert any 

objects into the contacts.  Use compressed air to blow out the build-

up ensuring proper contact and operation. 

 

 

 

 

 

 

 

 

 

 

 

 

For more information concerning best cleaning practices, contact our support 

team at www.jacoinc.com/support, email at [email protected] or call 877-

803-0101. 

 

 

 

 

 

 

 

 

 

  

 
 
 
 

Summary of Contents for Ultralite Power Blade Hot-Swap 300 Series

Page 1: ...25 0163 Rev 02...

Page 2: ...IGHT POSITION 8 INSTALLING YOUR COMPUTER OR LAPTOP 8 INSTALLING STAND AND LCD MONITOR 9 INSTALLING SCANNER MOUNTS 10 INSTALLING KEYBOARD AND MOUSE ONTO THE CART 10 OPTIONAL JACO PATENTED TRAC WHEEL ST...

Page 3: ...r placed on a Table or desk top whichever fits your workflow For complete details and instructions please reference the Power Blade Charger Users Guide that is shipped with each unit This manual is al...

Page 4: ...a P N Serial Number label for tracking and service assistance This label is located on the outside surface on the white raised area of the battery The information on this label is needed when contact...

Page 5: ...heel Base 16 x 13 x16 Cart Weight without options 310 Laptop Cart 75 lbs includes 2 Power Blade Battery Packs base counterweight 320 PC Cart 85 lbs including 2 Power Blade Battery Packs base counter w...

Page 6: ...ntrol which is available through your JACO contact The JACO 300 Series Power Blade status parameters and configuration files are fully accessible via the Cart s built in HTML web server Web pages are...

Page 7: ...the Shippers responsibility to follow all Federal State regulations when shipping lithium batteries WARNING Do not open or dismantle the JACO Power Blade Battery Pack or Power Blade Charger note that...

Page 8: ...t free of liquids dirt and dust and a max room temperature of 77 deg 25 C The Power Blade Charger should be reviewed weekly for proper care and cleaning The bays should be used only for the charging o...

Page 9: ...o change the height simply squeeze the handle located at the right side of the cart as shown below While holding the handle tight the cart height can be changed by pushing downward or pulling upward w...

Page 10: ...CD to the stand A Phillips Head or if added security is needed for the LCD Torx Head driver is needed to attached the LCD to the VESA Stand 4 places Both Phillips and Torx screws are provided It is re...

Page 11: ...liding keyboard tray With each JACO Mobile Cart we include an accessory pack that provides ty wraps and Velcro pads along with other helpful items for proper cable management Use the Velcro pads to fa...

Page 12: ...digit access codes To change the pass code press the numbers 3 1 2 then the unlock button you will hear a beep indicating that a new 4 digit code can be entered If you enter an unacceptable code such...

Page 13: ...r will switch instantly from one to the other when one Power Blade Battery Pack is removed LED Charge Capacity Status The Power Blade Battery Pack ports on the Mobile Cart are labeled as Battery 1 and...

Page 14: ...Battery Packs are designed to be a safe and reliable solution for health care applications As with any battery system the amount of time that the battery will power the equipment is dependent on the d...

Page 15: ...h each unit This manual is also available on request Agency Certification 51 4218 Power Blade Charger Safety IEC 60601 3rd Edition 60601 1 2005 A1 2012 IEC 60601 1 EN ISO 14971 EMI EMC 60601 1 2005 A1...

Page 16: ...fully charged batteries If the status LED s are still not showing you will need to reset the controller unit To reset insert a paper clip into the reset port at the back of the Cart as shown Once pape...

Reviews: