SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

ALIGNING THE MACHINE: 

Adjust the machine base to line up hole in table with hole in support

block (Fig. 11).

(Fig. 11)

INSTALLING THE INTERNAL VACUUM BREAKER: 

Insert internal vacuum

breaker pipe into hood support block pin end down (Fig.12). 

WARNING: Internal vacuum breaker pipe must be installed or
there will be a hazard to the operator.

(Fig. 12)

INSTALLING THE HOOD ASSEMBLY: 

Make sure there are two “O-

rings” (Fig. 5) on the lower support pipe near the end of the ring. While
also holding the internal vacuum breaker, lift the hood and hood support
pipe up over table. Set hood support pipe down into the support block
hole (Fig. 13) and begin to work the hex nut into the hole. The locating
pin in the support block will insure proper line up. While holding the sup-
port pipe, start tightening nut by hand to prevent cross threading. It
should tighten considerable by hand. Then continue tightening with a
wrench. It may be necessary to work support pipe back and forth to seat
nut properly. When the nut is tight, it should force flat the stainless steel
and rubber washers tight to the table top.

(Fig. 13)

Attach vacuum breaker support pipe clamp (Fig. 14) to the support pipe and
external vacuum breaker piping. Slide up about 12” from the table and tight-
en securely. Position cover plate (supplied with table) over square cutout in
backsplash on table so that it fits tightly around piping then snap in the four
nylon fasteners (supplied) to hold in place.

Rotate the hood to insure it is free, if not, check level of machine, tightness
of table to machine flange, centering of machine, level of table and hood
support pipe.

(Fig. 14)

Summary of Contents for 10U

Page 1: ...0AB 10APRB 10U HIGHER HOOD OPTION Jackson MSC INC P O BOX 1060 HWY 25E BARBOURVILLE KY 40906 FAX 606 523 9196 PHONE 606 523 9795 www jacksonmsc com An Company 10 SERIES ELECTRICALLY HEATED ROUND DISHM...

Page 2: ...ttempted repair by unau thorized persons improper installation if serial number has been removed or altered or if unit is used for purpose other than it was origi nally intended TRAVEL LIMITATIONS Jac...

Page 3: ...i REVISION REVISION DATE MADE BY APPLICABLE ECN DETAILS D 02 24 04 MAW N A ADDED 10U PHOTO INSTALLATION GUIDE AND ALL 10U INFORMATION...

Page 4: ...on MSC Inc provides technical support for all of the dishmachines detailed in this manual We strongly recommend that you refer to this manual before making a call to our technical support staff Please...

Page 5: ...ical Connection 10 Final Check 11 Operation Instructions 12 Detergent Control 13 III PREVENTATIVE MAINTENANCE Preventative Maintenance 15 IV ELECTRICAL SCHEMATICS 10A 208 220 V 60 HZ single phase 17 1...

Page 6: ...1 SECTION 1 SPECIFICATION INFORMATION...

Page 7: ...WASH PUMP MOTOR HP 1 2 RINSE PUMP MOTOR HP 10APRB ONLY 1 2 MODEL VOLTS HERTZ PHASE AMPS 10A 208 60 1 8 23 10A 220 60 1 8 23 10AB 10U 208 60 1 38 8 10AB 10U 208 60 3 25 6 10AB 10U 220 60 1 37 2 10AB 1...

Page 8: ...5 1 2 9 shorter leg 4 shorter hood 58 1 4 standard leg hood 63 1 4 standard leg 5 higher hood All dimensions in inches All vertical dimensions are 1 2 from the floor due to the adjustable bullet feet...

Page 9: ...10U only G Machine height 45 1 2 10U 10AB 10APRB 9 shorter leg 4 shorter hood 58 1 4 10AB 10APRB standard leg hood 63 1 4 10AB 10APRB standard leg 5 higher hood All dimensions in inches All vertical d...

Page 10: ...gend A 10 High backsplash 2 turnback at 45B B 3 High 1 1 2 diameter rolled edge C Scrap block D Scrap basket with slide bars E 20 x 20 x 5 deep pre rinse sink F Heavy duty pre rinse G 20 Slanted wall...

Page 11: ...6 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS...

Page 12: ...throw away the container The dishmachine has been inspected and packed at the factory and is expected to arrive to you in new undamaged condition However rough handling by carriers or others may resul...

Page 13: ...table Fig 7 with proper flange cutout over and above machine so that vertical flange on table cutout fits down inside of machine tub and horizontal flange on machine tub fits up tight against undersid...

Page 14: ...he locating pin in the support block will insure proper line up While holding the sup port pipe start tightening nut by hand to prevent cross threading It should tighten considerable by hand Then cont...

Page 15: ...e cycle It is also recommended that a shock absorber not supplied with the dishmachine be installed in the incoming water line This prevents line hammer hydraulic shock induced by the solenoid valve a...

Page 16: ...N INSTRUCTIONS INSTALLATION INSTRUCTIONS FINAL CHECK Check all fittings and connections before and after first 10 cycles Deliver Installation Operation Manual to site manager Contact Jackson for free...

Page 17: ...es WARE PREPARATION Proper preparation of ware will help ensure good results and less re washes If not done properly ware may not come out clean and the efficiency of the dishmachine will be reduced I...

Page 18: ...with your water treatment specialist and detergent vendor and come up with a complete training program for operators Using too much detergent has as detrimental effects as using too little The proper...

Page 19: ...14 SECTION 3 PREVENTATIVE MAINTENANCE...

Page 20: ...sh for five minutes d Open the door and examine the interior All lime should be removed and parts should be shiny If not allow to wash for a longer period e After the interior is clean empty the wash...

Page 21: ...16 SECTION 4 ELECTRICAL SCHEMATICS...

Page 22: ...CUSTOMER SERVICE L1 L3 L2 TERMINAL BOARD 1 CUSTOMER SERVICE 6900 WATTS 15 AMP RATING CIRCUIT BREAKER RINSE HEATERS WASH MOTOR HP 5 3 AMPS 630 WATTS HP 5 3 AMPS WASH HEATER RINSE MOTOR 09905 105 34 50...

Page 23: ...18 SECTION 4 ELECTRICAL SCHEMATICS 10A WIRING DIAGRAM 208 230 VOLT 60HZ SINGLE PHASE...

Page 24: ...19 SECTION 4 ELECTRICAL SCHEMATICS 10AB WIRING DIAGRAM 208 230 VOLT 60HZ SINGLE PHASE 9905 000 54 97...

Page 25: ...20 SECTION 4 ELECTRICAL SCHEMATICS 10AB WIRING DIAGRAM 208 230 VOLT 60HZ THREE PHASE 9905 002 55 90a...

Page 26: ...21 SECTION 4 ELECTRICAL SCHEMATICS 10APRB WIRING DIAGRAM 208 230 VOLT 60HZ SINGLE PHASE 9905 002 55 91a...

Page 27: ...22 SECTION 4 ELECTRICAL SCHEMATICS 10APRB WIRING DIAGRAM 208 230 VOLT 60HZ THREE PHASE 9905 002 55 92a...

Page 28: ...23 SECTION 5 JACKSON MAINTENANCE REPAIR CENTERS...

Page 29: ...FRANCISCO CA 94080 650 635 1900 800 424 1414 FAX 650 635 1919 pndappl aol com COLORADO HAWKINS COMMERCIAL APPLIANCE SERVICE 3000 S WYANDOT ST ENGLEWOOD CO 80110 303 781 5548 800 624 2117 FAX 303 761 8...

Page 30: ...ILLE KY 40214 502 367 1788 800 752 6160 FAX 502 367 0400 LOUISIANA BANA PARTS INC 1501 KUEBLE STREET HARAHAN LA 70123 504 734 0076 800 325 7543 FAX 504 734 8456 LOUISIANA cont BANA PARTS INC 4028 GREE...

Page 31: ...FAX 215 925 6208 NEW JERSEY cont ELMER SCHULTZ SERVICES 201 WASHINGTON AVE PLEASANTVILLE NJ 08232 609 641 0317 800 378 1641 FAX 609 641 8703 elmer2 erols com NEW MEXICO STOVE PARTS SUPPLY CO 2120 SOLA...

Page 32: ...FAX 215 627 5408 elmer2 erols com K D PARTS SERVICE 1833 41 N CAMERON STREET HARRISBURG PA 17103 717 236 9039 800 932 0503 FAX 717 238 4367 PENNSYLVANIA cont AMERICAN KITCHEN MACHIN ERY REPAIR 204 QUA...

Page 33: ...2660 PITTMAN DRIVE SILVER SPRING MD 20910 301 585 7550 DC 410 792 0388 BALT 800 638 7278 FAX 301 495 4410 GCS SERVICE INC RICHMOND VA 800 822 2303 WASHINGTON RESTAURANT APPLIANCE SVC 7219 ROOSEVELT W...

Reviews: