Zone Control Made Simple™
5418 Elmwood Avenue, Indianapolis, IN 46203-6025
Toll Free: 888.652.9663 Fax: 317.227.1034
www.jacksonsystems.com
Specifications
Panel Dimensions:
8.0 Inches
Height:
6.0 Inches
Width:
1.375 Inches
Depth:
Mounting:
Snap Track with 2 back plate screws
Operating Temperature Rating:
-40° F to 150° F
Operating Humidity:
5% to 90% RH non-condensing
Wiring:
18-gauge wire for all equipment
and system connections
Time Delays:
3 minutes minimum off between
heating and cooling calls
3 minutes minimum off on high and low
limit
20 minute time share
Thermostats:
Single or multi-stage heat pump
Programmable or non-programmable
Auto or manual changeover
Dampers:
D PC
Powered Closed
D C
Common
PO
Powered Open
High / Low Limit
DAS
Discharge Air Sensor
(2 wire)
Outdoor Thermostat
OTS
Used for Fossil Fuel
(2 wire)
HVAC Equipment:
RH
24Vac Heating Transformer
RC
24Vac Cooling Transformer
W
Auxiliary Heat
Y1
First Stage Compressor
Y2
Second Stage Compressor
G
Fan
O/B
Reversing Valve
Panel Power:
R
24Vac (Hot)
X
24Vac (Common)
Terminal Designations
Thermostats:
C
24Vac (Common)
R
24Vac (Hot)
W
Auxiliary Heat
Y1
First Stage Compressor
Y2
Second Stage
Compressor
G
Fan
06-1054-011510
ZONE DAMPER 3
ZONE DAMPER 1
ZONE 1
STAT
ZONE 3
STAT
Z-300
PANEL
24 VOLT
TRANSFORMER
FURNACE
DISCHARGE AIR
SENSOR
ZONE 2
STAT
ZONE DAMPER 2
Z-300-HPS Installation and Operation Instructions
3 Heat / 2 Cool Heat Pump or Dual Fuel
Auto Changeover - First Call Priority - Time Share
Z NE
N
E
E
R
G
E
H
T
Zone Control Made Simple
TM
TM
Typical System Layout
Purge ON = 1 minute