Jackson MSC TEMPSTAR HH Service Manual Download Page 1

TEMPSTAR HH

TEMPSTAR HH NB

SERVICE M

MANUAL

March 26, 2002

P/N 7610-002-23-32 (REV. C)

Visit Jackson on the Internet at:

www.jacksonmsc.com

HOT WATER SANITIZING UPRIGHT

DOOR DISHMACHINES

Summary of Contents for TEMPSTAR HH

Page 1: ...TEMPSTAR HH TEMPSTAR HH NB SERVICE M MANUAL March 26 2002 P N 7610 002 23 32 REV C Visit Jackson on the Internet at www jacksonmsc com HOT WATER SANITIZING UPRIGHT DOOR DISHMACHINES...

Page 2: ...tilever Arm Assembly 17 Yoke Assembly 18 Door Brackets 19 Incoming Plumbing Outlet Plumbing Assembly Tempstar HH 20 Incoming Plumbing Assembly Tempstar HH NB 22 Solenoid Valve Repair Kit Vacuum Breake...

Page 3: ...S PER MINUTE 73 FRAME DIMENSIONS WIDTH 25 3 4 DEPTH 25 1 4 HEIGHT 68 1 2 STANDARD TABLE HEIGHT 34 MAXIMUM INSIDE CLEARANCE 27 RACKS DISH 20 X 20 OPTIONAL GLASS SILVER 20 X 20 OPTIONAL ELECTRICAL REQUI...

Page 4: ...inimum 1 1 2 I P S and shall not be reduced There must also be an air gap between the machine drain line and the floor sink or drain If a grease trap is required by code it should have a flow capacity...

Page 5: ...through the cycle and shut off automatically Repeat this two more times The unit should now be ready to proceed with the washing of ware WASHING A RACK OF WARE To wash a rack open the doors completely...

Page 6: ...e the cam timer will move for the first 30 seconds of the wash cycle The cycle delay timer will then cause the cam timer to stop in order to increase the length of the wash cycle The red light on the...

Page 7: ...the wash pump Tighten the hose clamps Problem Will not rinse during autocycle 1 Defective rinse solenoid Repair or replace the rinse solenoid as required 2 Faulty fill microswitch Replace microswitch...

Page 8: ...TH DISHTABLE 4 ALL DIMENSIONS IN INCHES 68 1 2 73 3 4 86 1 4 15 3 8 25 1 4 3 25 LEGEND A DRAIN 1 1 2 I P S B WATER INLET 3 4 I P S C ELECTRICAL CONNECTION D STANDARD WALL CLEARANCE WITH DISHTABLE IS 4...

Page 9: ...RNER INSTALLATION TABLE DIMENSIONS CONNECTION TO DISHMACHINE TABLE DIMENSIONS STRAIGHT THROUGH INSTALLATION 20 1 2 OPENING 25 1 4 2 1 4 4 MIN 2 1 2 4 MIN 20 1 2 OPENING 25 1 4 20 1 2 3 4 1 1 2 ROLL 4...

Page 10: ...MAIN ASSEMBLY 8 1 3 4 2 5 6 2 7 8 11 10 12 9 Represents an item not shown...

Page 11: ...r Lower Front 5700 031 76 77 2 Glide Lower Door 5700 002 23 64 4 1 Door Lower Left Assembly 5700 002 01 32 1 Door Lower Left 5700 031 76 79 2 Glide Lower Door 5700 002 23 64 5 1 Cover Front Panel 5700...

Page 12: ...CONTROL BOX ASSEMBLY 10 4 7 8 9 13 29 30 31 32 27 28 25 26 14 11 15 16 17 10 11 12 1 2 3 5 6 24 11 22 23 21 18 19 20 21 Represents an item not shown...

Page 13: ...303 31 00 15 1 Contactor 2 Pole 220V 20AMP 5945 109 03 69 16 3 Screw 10 32 x 3 8 Phillips Pan Head 5305 173 26 00 17 1 Timer Cycle Delay 5945 002 13 78 18 1 Terminal Block 3 Pole 5940 011 48 27 19 1...

Page 14: ...ong Hex 5305 274 02 00 6 2 Right Left Front Outer Door Guide 5700 031 76 85 7 2 Right Left Front Inner Door Guide 5700 031 76 82 8 2 Right Left Front Hood Support Weldment 5700 002 17 68 9 1 Left Rear...

Page 15: ...4 21 9 10 23 21 22 14 23 17 25 26 SEE PAGE ENTITLED WASH RINSE HEATERS 16 Pump Support Bracket Complete Assembly 5700 002 00 46 Nut 1 4 20 Serrated Nut 5310 011 66 49 Pump Support Main Bracket Weldmen...

Page 16: ...0 002 10 19 17 1 Discharge Hose 5700 011 88 24 18 1 Nipple 5700 021 34 84 19 1 Clamp Hose 5 5 8 to 6 4730 011 34 90 20 1 Probe High Water 6680 200 02 68 21 2 Thermostat Bracket 5700 011 73 72 22 1 The...

Page 17: ...t thermostat is used to protect the heater element in the event of a run away regulating thermostat or a dry fire situation It is set for 210 F 0 or 10 F with a fixed set point This part is not adjust...

Page 18: ...Weldment 5700 021 50 07 Suction Strain Weldment 5700 002 16 13 Suction Strain Bracket 5700 002 18 28 Rack Guide 5700 001 28 19 Rack Weldment 5700 002 01 01 Screw 10 24 x 1 2 Long 5305 173 18 00 Locknu...

Page 19: ...CANTILEVER ARM ASSEMBLY 17 1 2 3 4 5 6 9 10 7 8 18 19 18 21 20 17 14 16 12 15 13 11 12 14 22...

Page 20: ...Long Hex Head 5305 274 23 00 12 4 Washer 1 4 ID S S 5311 174 01 00 13 2 Sleeve Cantilever Arm 5700 000 85 69 14 4 Locknut 1 4 20 S S Low Profile W nylon Insert 5310 374 02 00 15 2 Screw 1 4 20 X 1 2...

Page 21: ...No 1 6 Door Stop Weldment 5700 002 29 60 2 32 Locknut 1 4 20 w Nylon Insert 5310 374 01 00 3 32 Washer 1 4 20 I D 5311 174 01 00 4 6 Wear Button 5700 011 88 01 5 1 Door Stop 5700 002 00 84 6 1 Door S...

Page 22: ...d tape used in conservative amounts be applied to threads when joining components together It is not advised to use thread sealing compounds sometimes referred to as pipe dope Compounds can be ejected...

Page 23: ...0 4 Adapter 3 4 Male 4730 401 11 01 11 1 Tube Copper 3 4 x 48 Long 5700 011 87 89 12 2 Elbow 3 4 90 Degree 707 Copper 4730 406 16 01 13 3 Adapter 3 4 604 2 4730 401 10 01 14 1 Tube Copper 3 4 x 3 1 4...

Page 24: ...0 206 04 34 3 1 Nipple Brass 3 4 NPT x 3 4730 011 38 29 4 1 Union Brass 3 4 NPT 4730 212 05 00 5 3 Nipple Close Brass 3 4 NPT 4730 207 34 00 6 1 Valve Solenoid 3 4 NPT 4810 100 03 18 7 1 Tee Brass 3 4...

Page 25: ...y Goes below the plunger O Ring 4810 100 10 18 Diaphragm Retainer Diaphragm 4810 100 10 18 Screen Retainer Mesh Screen Valve Body Complete 220 Volt Solenoid Valve Assembly Mfg No 4810 100 03 18 Coil H...

Page 26: ...SH RINSE ARM MANIFOLD ASSEMBLIES 24 13 18 14 11 12 15 15 14 13 11 2 3 4 5 7 16 8 6 10 5 9 7 1 DETAIL B WASH ARMS MANIFOLD DETAIL A FINAL RINSE ARMS MANIFOLD 12 10 10 10 10 5 17 20 16 2 3 19 5 20 9 17...

Page 27: ...Manifold 5700 111 35 03 9 1 Wash Arm Weldment 5700 021 35 93 10 5 Locknut 1 4 20 S S Hex w Nylon Insert 5310 374 01 00 11 2 Clip Retaining Rinse Head Bushing 5340 112 01 11 12 4 Rinse Arm Washer 5330...

Page 28: ...ER MOUNTING BOX 26 460V Transformer 5950 111 65 93 2 Amp Circuit Breaker 5925 111 64 18 Transformer Mounting Bracket 5700 031 62 82 Transformer Mounting Box 5700 002 10 01 Transformer Mounting Box Top...

Page 29: ...Box Bottom 5700 001 21 26 Safety Door Interlock Box Cover 5700 001 21 27 Other Safety Door Interlock SDI components not shown Pipe Clamp found on the side of the machine 5700 000 35 05 Solenoid Electr...

Page 30: ...EXHAUST FAN CONTROL OPTION 28 Delay Timer 5945 011 65 44 2 Din Rail 5700 002 36 09 Terminal Board 5940 011 84 41...

Page 31: ...rd 5 The panel will clip in at the top inside of the unit 6 The holes in the false panel will line up with the rack assembly holes 7 Re install the screws for the rack assembly which will secure the f...

Page 32: ...30 Tempstar HH ELECTRICAL DIAGRAM 208 230 Volt 60 Hertz Single Three Phase...

Page 33: ...Tempstar HH ELECTRICAL DIAGRAM 460 Volt 60 Hertz Three Phase 31...

Page 34: ...DELIME SWITCH S4 SELECTOR SWITCH CYCLE 4 S5 SELECTOR SWITCH CYCLE 3 S6 SELECTOR SWITCH CYCLE 2 S7 SELECTOR SWITCH CYCLE 1 C1 CYCLE SWITCH C2 AUTO START RESET SWITCH C3 WASH CYCLE SWITCH C4 RINSE FILL...

Page 35: ...Tempstar HH NB ELECTRICAL DIAGRAM 460 Volt 60 Hertz Three Phase 33...