Flame Diffusers, Cooking Grids Installation:
1. Remove the flame diffusers form the packaging. Please ensure that all protective plastic has been
removed from these parts. These flame diffusers should be placed on the ledge installed on the
firebox front and rear. Ensure that all of the flame diffusers have been installed correctly in the slots
provided or the unit will not work correctly.
2. Once the flame diffusers have been installed, the cooking grids can be installed into the grill. Place
the cooking grills on the upper ledge of the firebox.
3. Remove warming rack from packaging and install above cooking grids on the 2 brackets on the
inner hood.
Rear Burner Igniter:
1. Unscrew the plastic/rubber cap from the rear burner ignition module and insert the supplied AAA
battery, positive side facing out. Re-install cap.
LED Light:
1. Open the folding access panel on the underside of LED light base and install 3 supplied AAA
batteries.
Gas Connection
ONLY USE THE REGULATOR AND HOSE ASSEMBLY PROVIDED WITH THIS GRILL.
REPLACEMENT PRESSURE REGULATORS AND HOSE ASSEMBLIES MUST BE
THOSE SPECIFIED BY THE MANUFACTURER.
This is a L.P. (Liquefied Petroleum Gas) configured grill. Do not attempt to use a natural gas supply
unless the grill has been reconfigured for natural gas use.
The installation of this appliance must conform with local codes or, in the absence of local codes, with
the
National Fuel Gas Code, ANSI Z223. 1, or CAN/CGA-B149.2 Propane Installation Code.
L.P. tank Requirements:
The L.P. tank used with your grill must meet the following requirements:
1. Measurement: 12
’’(30.5cm) (Diameter) X 18’’ (45.7cm) (Tall)
2. Maximum Capacity: 20lbs. (9Kg)
3. Constructed and marked in accordance with the specification for L.P.-gas cylinders of the
U.S.
Department of Transportation (DOT)
or
the National Standard of Canada, CAN/CSA-B339,
Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods.
See L.P. tank collar
for marking.
4. Be arranged for vapor withdrawal.
5. Has a collar to protect the tank valve.
6. No dents or rust. A dented or rusty L.P. tank may be hazardous.
L.P. tank valve used must meet the following requirements:
1. Have type I outlet compatible with regulator provided.
2. Have safety relief valve.
3. UL listed Overfill Protection Device (OPD), This OPD safety feature is identified by a unique
triangular hand wheel.
Only use tanks equipped with this type of valve. (as the figure shown