background image

www.PumpAgents.com

Model 6050-0713

WASTE TANK PUMP-OUT SYSTEM

FEATURES

Pump:

Self-Priming Flexible Impeller,
Bronze

Impeller: 

Jabsco Nitrile Compound

Seal:

Lip Type

Motor:

3/4 HP Capacitor Type, Overload
Protector, 1725 RPM, 60 Hz Single
Phase, 115 Vac with 8' cord and plug

Switch:

Vacuum Switch, Automatic

D i s c h a rge Port :

1" NPT, Internal

Suction Hose:

6050-0713 - 15', 1-1/4" ID Heavy Duty,
Flexible Reinforced

Nozzle:

Tapered Soft Rubber with check valve.
Fits 1-1/2" Diameter deck fittings.

Shaft:

Steel Motor Shaft protected by
Stainless Steel Impeller Sleeve

APPLICATION

Designed for use as a holding tank pump out system.
Extra large ports prevent clogging. Pumps 18 gallons
per minute and will pump up to 50 ft head. The unit is
portable and compact for easy handling. Pump is a
Jabsco bronze, self-priming design (close coupled) to a
rugged 3/4 HP 115 Vac single phase 60 Hz motor.

Comes complete with suction hose and right angle deck
fitting nozzle with built-in check valve to prevent back
flow. An automatic vacuum switch shuts the pump off
when the vessel's holding tank is empty. No need to
stand by while pumping out and no damage to the pump.

PLUMBING

1.

Attach end of suction hose adaptor to suction port
on pump (right port when facing pump) and clamp
securely.

2.

Connect a suitable discharge hose or pipe (not
supplied with pump) to discharge port. For maximum
e fficiency and performance, use a minimum of 1-1/2"
(38mm) diameter hose or pipe in installations requiring
a total of 50' to 150' (15.2 to 45.7m) piping. For
installations requiring 25' to 50' (7.6 to 15.2m) total
piping, use a minimum of 1-1/4" (32mm) diameter
hose or pipe. For installations requiring less than 25'

(7.6m) total piping, use a minimum of 1" (25mm)
diameter  hose  or  pipe.  For  unusually  long  or
complicated  piping  systems,  contact  factory  for
engineering assistance.

OPERATION

1.

Connect pump to 115 Volt AC power source. Make
sure that adequate voltage and current capacity are
available.

2.

Press suction nozzle firmly into waste fitting, being
sure to make an airtight seal.

3.

Press lever on vacuum switch down for a few
seconds to start the pump. The lever will stay down
as long as the unit is pumping. When tank is
completely pumped out, it will shut off automatically.
If lever will not stay down on start up, check to be
sure suction nozzle is airtight and that there is liquid
in the tank. Also ensure deck-plate construction
does not create an air leak.

DO NOT HOLD LEVER DOWN FOR MORE THAN 15
SECONDS. IF PUMP IS RUN DRY FOR LONGER
THAN 1 MINUTE, IMPELLER MAY BE DAMAGED.

THIS PUMP OUT SYSTEM MUST BE USED
WITH PROPER SHORESIDE FACILITIES, IN
ACCORDANCE WITH FEDERAL EPA/USCG
AND LOCAL REGULATIONS.

PumpAgents.com - buy pumps and parts online

PumpAgents.com - Click here for Pricing/Ordering

Summary of Contents for 6050-0713

Page 1: ...suitable discharge hose or pipe not supplied with pump to discharge port For maximum efficiency and performance use a minimum of 1 1 2 38mm diameter hose or pipe in installations requiring a total of 50 to 150 15 2 to 45 7m piping For installations requiring 25 to 50 7 6 to 15 2m total piping use a minimum of 1 1 4 32mm diameter hose or pipe For installations requiring less than 25 7 6m total pipi...

Page 2: ...rplate 1 4156 0010 7 Seal 1 92700 0080 8 Screw Cam 1 91004 0110 9 Body 1 6054 0010 10 Motor 1 18736 0000 11 Nut Clamp 1 91105 0030 12 Bolt Clamp 1 91095 0090 13 O Ring Slinger 1 18753 0086 14 Vacuum Switch Kit 1 4732 0000 Service Kit 90058 0003 These parts are supplied in Service Kit EXPLODED VIEW Pump Motor Assembly O Ring 92000 0540 used in models prior to 1958 PumpAgents com buy pumps and parts...

Page 3: ... Number 19 Hose Clamp 1 93002 0130 21 Suction Hose 1 93003 0200 23 Elbow 1 92003 0050 24 Hose Clamp 1 93002 0120 25 Nozzle 1 18476 0000 26 Nozzle Assemble 1 17436 0000 Elbow 92003 0050 Hose Clamp 93002 0120 and Nozzle 18476 0000 are supplied together as part 17436 000 PumpAgents com buy pumps and parts online ...

Page 4: ...ABSCO IN CONNECTION WITH THIS WARRANTY SHALL NOT IN ANY CASE EXCEED THE CONTRACT PRICE FOR THE PRODUCT CLAIMED TO BE DEFECTIVE OR UNSUITABLE 4 This warranty does not extend to any product manufactured by Jabsco which has been subjected to misuse neglect accident improper installation or use in violation of instructions furnished by Jabsco 5 This warranty does not extend to or apply to any unit whi...

Page 5: ...or service please take your pump into your local pump service center To order pump or parts or for pricing please go to the following links Jabsco Pumps Home Jabsco Pumps stock list PumpAgents com buy pumps and parts online ...

Reviews: