www.PumpAgents.com
Model 37010-Series
Model 37010-Series
ELECTRIC MARINE TOILET
Push Button Operation
FEATURES
• White Vitreous China Bowl Available in Two Sizes
• Baked Enamel Seat & Cover in Compact or
Household Size
• Flexible Impeller Flush Pump
• Permanent Magnet Type Motor, Fully Enclosed, with
Stainless Steel Shaft
• High Capacity Macerator and Bowl Scavenger Pump
• Built-in Back Flow Preventer
• All Corrosion Resistant Material for Marine Use
VARIATIONS
VOLTAGE
COMPACT SIZE
HOUSEHOLD SIZE
12 Vdc
37010-0000
37010-1000
12 Vdc EMC
37010-0090
37010-1090
24 Vdc
37010-0006
37010-1006
24 Vdc EMC
37010-0096
37010-1096
INSTALLATION
The Jabsco electric toilet may be installed above or below
the waterline. Flush pump is self-priming with a vertical lift
up to 4 feet; discharge macerator pump can operate
against a vertical head up to 4 feet.
Inlet and outlet seacocks should be easily accessible and
be positive shut off valves. If seacocks cannot be conve-
niently operated from toilet location, install suitable shut off
valves for inlet and discharge connections.
Base assembly may be moved 90° to accommodate con-
nections and provide accessibility for servicing.
Surface where toilet is mounted should be flat to prevent
distortion of toilet base.
PLUMBING CONNECTIONS - Connect inlet hose using
either 5/8" or 3/4" ID hose (a sleeve is included to adapt
pump inlet from 5/8" to 3/4"). Make sure all inlet connec-
tions are airtight and free of sharp bends or restrictions.
Connect 1" or 1-1/2" hose to discharge port (Adaptor
98023-0080 is included to convert discharge port to 1-1/2"
ID hose), and make suitable connection to holding tank or
other discharge system. Avoid sharp bends or restrictions.
For above waterline installations, a check valve may have
to be installed in the flush water intake line to ensure rapid
pump priming. To retain water in bowl, make a loop in the
discharge line about 8 inches above base of bowl.
Do not connect the toilet to the vessels
potable water for its source of supply. To do so can result
in contamination of potable water supply. If fresh water is
preferred for flushing, provide a separate fresh water tank
to supply water to the toilet only.
DO NOT CONNECT INLET HOSE TO A
PRESSURIZED
WATER SYSTEM.
If the toilet is, or can be, below waterline at any normal
(including static) attitude of vessel heel and/or trim, a 3/4"
Vented Loop Fitting must be installed in the length of hose
connecting the flushing pump to the inlet seacock. The
Vented Loop Fitting must be positioned so it remains slightly*
above the waterline at all angles of heel and trim.
In some installations when a vented loop is installed in the
intake hose, the flushing pump primeability and flow char-
acteristics are reduced and may adversely affect toilet
function. To restore pump performance, connect a solenoid
valve (Jabsco No. 37068-0000) to the vent air inlet to inter-
rupt the air supply during the flush cycle. The brass port of
the solenoid valve (remove plastic filter if attached) should
be connected to the vent inlet with 3/16" hose and the
solenoid wired in parallel with the toilet motor. See
Diagram 1 for installation and wiring illustration.
* Recommended minimum height above waterline is 6".
Flood hazard. If toilet is installed below the
waterline or may be below the waterline at any
angle of heel or trim, it must be installed with
properly positioned vented loops. Failure to do
so can result in flooding which can cause loss
of property and life.
WARNING
!
CAUTION
!
PumpAgents.com - buy pumps and parts online
PumpAgents.com - Click here for Pricing/Ordering