1
Model 37010-Series
ELECTRIC MARINE TOI LET
Push Button Operation
FEATURES
• White Vitreous China Bowl Available in Two Sizes
• Baked Enamel Seat & Cover in Compact or
Household Size
• Flexible Impeller Flush Pump
• Permanent Magnet Type Motor, Fully Enclosed, with
Stainless Steel Shaft
• High Capacity Macerator and Bowl Scavenger Pump
• Built-in Back Flow Preventer
• All Corrosion Resistant Material for Marine Use
VARIATIONS
VOLTAGE
COMPACT SIZE
HOUSEHOLD SIZE
12 Vdc EMC
37010-0090
37010-1090
24 Vdc EMC
37010-0096
37010-1096
INSTALLATION
The Jabsco electric toilet may be installed above or below
the waterline. Flush pump is self-priming with a vertical lift
up to 4 feet; discharge macerator pump can operate
against a vertical head up to 4 feet.
Inlet and outlet seacocks should be easily accessible and
be positive shut off valves. If seacocks cannot be
convenient ly operated from toilet location, install suitable
shut off valves for inlet and discharge connections.
Base assembly may be moved 90° to accommodate
connec tions and provide accessibility for servicing.
Surface where toilet is mounted should be flat to prevent
distortion of toilet base.
PLUMBING CONNECTIONS - Connect inlet hose using
either 5/8" or 3/4" ID hose (a sleeve is included to adapt
pump inlet from 5/8" to 3/4"). Make sure all inlet connections
are airtight and free of sharp bends or restrictions.
Connect 1" or 1-1/2" hose to discharge port (Adaptor
98023-0080 is included to convert discharge port to
1-1/2" ID hose), and make suitable connection to holding
tank or other discharge system. Avoid sharp bends or
restrictions.
For above waterline installations, a check valve may have
to be installed in the flush water intake line to ensure rapid
pump priming. To retain water in bowl, make a loop in the
discharge line about 8 inches above base of bowl.
DANGER
!
CAUTION
!
WARNING
!
WARNING
Flood hazard. Any toilet installed below the waterline
or which may be below the waterline at any angle of
heel or trim must be intalled with properly positioned
vented loops. Failure to do so can result in flooding
which can cause loss of property and life.
Do not connect the toilet to the vessels
potable water for its source of supply. To do so can result
in contamination of potable water supply. If fresh water is
preferred for flushing, provide a separate fresh water tank
to supply water to the toilet only.
DO NOT CONNECT INLET HOSE TO A
PRESSURIZED
WATER SYSTEM.
If the toilet is, or can be, below waterline at any normal
(including static) attitude of vessel heel and/or trim, a 3/4"
Vented Loop Fitting must be installed in the length of hose
connecting the flushing pump to the inlet seacock. The
Vented Loop Fitting must be positioned so it remains slightly*
above the waterline at all angles of heel and trim.
In some installations when a vented loop is installed in the
intake hose, the flushing pump primeability and flow
characteristics are reduced and may adversely affect
toilet function. To restore pump performance, connect a
solenoid valve (Jabsco No. 37068-2000) to the vent air
inlet to interrupt the air supply during the flush cycle.
Screw the ¼” brass connector onto the vented loop and
wire the solenoid in parallel with the toilet motor. See
Diagram 1 for installation and wiring illustration.
*Recommended minimum height above waterline is 6".
ELECTRICAL CONNECTIONS - Select a location for
the switch and instruction plate, making sure wire leads
from both the toilet and power source can be routed to
the switch. Ensure the panel where installing switch is
no more than 1" thick. Drill a 5/8" mounting hole and
install switch and instruction plate. Use stranded copper
wire of the correct size (determined from the electrical
specifications chart) to connect one side of the switch to
the positive power source. An appropriate size fuse or
CAUTION