www.PumpAgents.com
U.S.A.
Jabsco
Cape Ann Industrial Park
Gloucester, MA 01930
Tel:
978.281.0440
Fax: 978.283.2619
UNITED KINGDOM
Jabsco
Bingley Road, Hoddesdon
Hertfordshire EN11 OBU
Tel:
+44 (0) 1992 450145
Fax: +44 (0) 1992 467132
CANADA
Fluid Products Canada
55 Royal Road
Guelph, Ontario N1H 1T1
Tel:
(519) 821.1900
Fax: (519) 821.2569
JAPAN
NHK Jabsco Company Ltd.
3-21-10, Shin-Yokohama
Kohoku-Ku, Yokohama, 222
Tel:
045.475.8906
Fax: 045.475.8908
GERMANY
Jabsco GmbH
Oststrasse 28
22840 Norderstedt
Tel:
+49-40-53 53 73 -0
Fax: +49-40-53 53 73 -11
THE PRODUCTS DESCRIBED HEREIN ARE
SUBJECT TO THE JABSCO ONE YEAR LIMITED
WARRANTY, WHICH IS AVAILABLE FOR YOUR
INSPECTION UPON REQUEST.
© Copyright 2004, ITT Industries
Printed in U.S.A.
All Rights Reserved
Form: 43000-0753
Rev. 02/2004
TROUBLESHOOTING
PULSATING FLOW – PUMP CYCLES ON AND OFF
Restricted pump delivery. Check discharge lines, fit-
tings and valves for undersizing or clogging. Clean
screens in faucets. Some filters or purifiers are highly
restrictive. Filters/purifiers with high pressure drop may
require a separate line and the installation of an accu-
mulator tank in the system.
FAILURE TO PRIME – MOTOR OPERATES, BUT NO
PUMP DISCHARGE
Restricted intake or discharge line.
Air leak in intake in line.
Punctured pump diaphragm (water leak).
Debris under flapper valves.
Crack in pump housing.
MOTOR FAILS TO TURN ON
Loose wiring connection.
Pump circuit has no power.
Blown fuse/Thermal Protector tripped (wait 30 min.).
Pressure switch failed.
Defective motor.
PUMP FAILS TO TURN OFF AFTER ALL FIXTURES
ARE CLOSED
Empty water tank.
Punctured pump diaphragm (water leak).
Discharge line leak.
Defective pressure switch.
Insufficient voltage to pump.
Debris under flapper valves.
LOW FLOW AND PRESSURE
Air leak at pump intake.
Accumulation of debris inside pump and plumbing.
Worn pump bearing (excessive noise).
Punctured pump diaphragm (water leak).
Defective motor.
ACCESSORIES
SNAP-IN PORT SYSTEM
WINTERIZING YOUR WATER SYSTEM
To winterize, it is not necessary to drain the water from
the entire water system. Blowing into the lines to remove
the water from your water system is not satisfactory due
to the check valve mechanism built into the pump.
Follow these steps to remove all water from your water
system:
1. Drain water by opening tank drain, or open a fixture to
allow pump to operate until tank is dry.
2. Open the lowest outlet in water system to drain lines.
3. To remove any remaining water (about a cup), remove
outlet hose on pump and activate pump. To blow out
lines, attach air nozzle where outlet hose was
removed. Make sure all fixtures are open before starting.
4. Your water system is now winterized. Don’t forget to
reattach the outlet hose to pump and close all fixtures.
PAR-MAX pumps have thermal overload protected motors. The motor will automatically shut off as
temperature rises due to an overload condition. If the motor shuts off in this manner, close all nozzles, faucets or
valves. After a cooling off period, the pump will automatically re-start.
DO NOT USE AUTOMOTIVE TYPE ANTI-FREEZE. IT IS POISONOUS. USE OF THIS TYPE ANTI-
FREEZE WILL CAUSE SERIOUS INTERNAL INJURY OR DEATH.