8
All dimensions in millimetres with inch equivalents in brackets.
Dimensions and Weights
Trouble Shooting
Bowl fills when toilet not
•
in use
Shut Seacocks.
-
Fit Vented Loops
-
Waste water re-appears
•
in bowl
Check Bottom Valve Gasket
-
(16) and Joker Valve (33).
Bowl does not empty &
•
difficult to push handle
down
Open Outlet Seacock.
-
Fully shut Flush Control Lever
-
(23).
Check Joker Valve (33),
-
Discharge Hose or Outlet
Seacock for blockage.
•
Bowl does not empty
and difficult to pull
handle up
Remove pump and check for
-
blockage.
Bowl does not empty
•
although handle is easy
to push & pull
Check Piston O-ring (30),
-
Bottom Valve Gasket (16) &
Joker Valve (33).
•
Water does not come in
and handle springs up if
pushed down
Open Inlet Seacock.
-
Fully open Flush Control
-
Lever (23).
Water does not come in
•
although handle is easy
to push and pull
Open Flush Control Lever
-
(23).
Check Top Valve Gasket (21)
-
and Piston O-ring (30).
Check Inlet Hose connections
-
are airtight.
•
Flush water is slow to
appear during pumping
Shorten Inlet Hose from main
-
Seacock.
Do not fit Vented Loop
-
between Inlet Seacock &
Pump
Fit between Pump & Bowl.
-
Fit Non-Return Valve (29295-
-
1011) next to Inlet Seacock.
View X-X outline
(showing base fixing holes)
Diam. 19mm
(0.75") I.D.
Hose inlet
Diam. 38mm (1.5")
I.D. Hose outlet
(multi angle)
4 holes Diam. 9mm (0.35")
Model No
Description
Net Weight
A
B
C
D
E
F
G
29090-3000
MANUAL TOILET COMPACT BOWL
9.5kg
(21lb)
335
(13.19)
615
(24.21)
247
(9.72)
425
(16.73)
485
(19.09)
450
(17.72)
165
(6.50)
mm
(ins)
29120-3000
MANUAL TOILET REGULAR BOWL
10.9kg
(24lb)
345
(13.58)
700
(27.56)
280
(11.02)
490
(19.29)
580
(22.83)
465
(18.31)
180
(7.09)
mm
(ins)