OPERATING INSTRUCTIONS (Cont.)
7. PRESSURES - Consult Head Capacity Table for
recommended maximum for continuous operation. If
pressures exceed those shown, consult the factory.
8. TEMPERATURES - Neoprene 45°-180° F (7°-82° C),
Nitrile 50°-180° F (10°-82° C).
9. FREEZING WEATHER - Drain unit by loosening end
cover. The following anti-freeze compounds can be
used without any adverse effects to the neoprene impeller:
Atlas “Permaguard”, DuPont “Zerex” and “Telar”, Dow
Chemical “Dowguard” and Olin Mathison “Pyro
Permanent”. Most methyl alcohol (methanol) based
antifreeze can be used with neoprene. (DO NOT USE
PETROLEUM BASED ANTI-FREEZE COMPOUNDS
OR RUST INHIBITORS.)
10. SPARE PARTS - To avoid costly shut downs, keep a
JABSCO Service Kit on hand.
KEY
DESCRIPTION
PART NO.
QTY
1
SCREW KIT (CAM & END COVER SCREWS)†
18753-0134
1
2
ENDCOVER
11836-0000
1
3
*O-RING
18753-0133
1
4
*IMPELLER
1
NEOPRENE
1210-0001
NITRILE
1210-0003
5
*SEAL
92700-0060
1
6
CAM
1
FULL THICKNESS
490-0001
HALF THICKNESS
2434-0000
7
SCREW, CAM
SEE KEY1
8
BODY
18753-0128
1
9
RETAINING RING
18753-0131
1
10
SLINGER
3286-0000
1
11
BEARING
92600-0120
2
12
SHAFT
18753-0129
1
13
RETAINING RING
18753-0132
1
14
KEY
9215-0010
1
SERVICE KIT
NEOPRENE
90015-0001
NITRILE
90015-0003
PARTS LIST
*
Parts supplied in Service Kit. Also included is an end cover gasket for older model pumps. Do not use gasket with O-ring end
cover seal.
†
Screw Kit contains 7 each #10-32 x 3/8” pan. hd. mach. screws and 1 each #10-32 x 5/16”pan. hd. mach. screw.
The 5/16” screw is used only with a half thickness cam.
EXPLODED VIEW