background image

1 Litre Accumulator Tank

To replace the air cushion:

1. Turn off the power to the water pump.

2.  Open the tap farthest from the accumulator tank.

3.  Remove the plug in the top of the accumulator tank.

4.  Open the drain cock, if fitted, or loosen the pipe

joint on the pump delivery side, to drain the water

system.

NOTICE

• Hand tighten only. Do not overtighten top plug or ‘T’

fitting as this will damage the tank.

• Plastic or similar fittings only are recommended.

• Do not paint the accumulator tank as this may lead

to deterioration of the plastic material.   

Warranty: All products of the company are sold and all services of the company are offered subject to the company’s warranty and terms and conditions of sale, copies of which will be furnished upon request.
The information provided herein is for guidance only, it does not constitute a guarantee of the performance or specification of any individual product or component.

©Copyright 2000 ITT Industries                                                                    

Discover Jabsco at www.jabsco.com

43001-0513 Rev: 03/03

Jabsco

ITT Industries

Jabsco,

20 Icon, Foothill Ranch, CA 92610

Tel : + 1 949 609 5106

Fax : +1 949 859 1254

Jabsco

Bingley Road, Hoddesdon, Hertfordshire, EN11 0BU

Tel : +44 (0) 1992 450 145

Fax : +44 (0) 1992 467 132

Fluid Products Canada

,

55 Royal Road, Guelph, Ontario N1H 1T1

Tel : +1 519 821 1900

Fax : +1 519 821 5316

NHK Jabsco Co Ltd

,

3-21-10, Shin - Yokohama, Kohoku-ku, Yokohama 222

Tel : +81 (0) 45 475 8906

Fax : +81 (0) 45 475 8908

Jabsco GmbH

,

Oststraße 28, 22844 Norderstedt

Tel : +49 (0) 40 53 53 73 0

Fax : +49 (0) 40 53 53 73 11

USA

UK

CANADA

JAPAN

GERMANY

Do not overpressurise the tank. Pressures

over 125psi (8.5 bar) may rupture tank and

cause personal injury.

Maintenance

Over time, the air cushion will be absorbed. This is
apparent when the pump starts to cycle rapidly if only
a small amount of water is used, for example by a
leaking tap, or when an instantaneous gas heater is
being operated on maximum heat setting.

5.  Replace plug and washer in top of the accumulator

tank.

6. Close the drain cock, if fitted, or re-connect the

pipe joint, and leaving the tap furthest from the tank

open, switch on the pump. When water is flowing

smoothly, close the tap. The system should then

shut off automatically.

Dimensional Drawing

Reviews: