The UC-82 wireless relay output module
MHT51100
2
To extend an existing hard-wired system with wireless detector(s)
– enroll
the detector(s) to relay X in mode 4 and once again to relay Y in mode 3. This
way the X relay will work as a detector trigger output, the Y relay as a detector
tamper output and the Low bat terminal will provide low battery indication. Up to
8 detectors can be enrolled to the UC-82 this way and the corresponding output
will be triggered if any of the enrolled detectors reports triggering, tampering or a
low battery.
Using the UC-82 with control panel PG output signals
•
if the control panel is enrolled to the X relay (in mode 4 by entering 299) then
the
X relay works as a control panel PGX output.
•
if the control panel is enrolled to the Y relay (in mode 4 by entering 299) then
the
Y relay works as a control panel PGY output.
•
Only
one
control panel PG output
can be
enrolled
to each relay.
No other
transmitting devices can be enrolled to a relay already occupied by a control
panel PG output.
Resetting the UC-82 unit
New UC-82 units are sold with factory-default settings (i.e. both relays
have nothing enrolled). To reset a particular relay, do the following:
•
Repeatedly press the X button (or the Y button for the Y relay) to
achieve the highest number LED flashes (4, or if not possible, then 3).
•
Then, continuously press the same button and keep pressing it until all
the LEDs flash a couple of times (=Reset). Then release the button.
Technical specifications
Power supply:
10 to 14V DC, standby consumption approx. 20mA
X and Y relay contact rating:
max
2A/24V DC or 2A/120V AC
Low bat terminal:
max 100mA/24V DC
TMP terminals:
max 100mA/24V DC
Communication band:
868 MHz, Oasis protocol
Minimum distance from transmitting devices
1 meter
Operating environment class II
general, indoor –10 to +40 °C
Enclosure
IP40 EN 60529
Mechanical immunity
IK08 EN 50102
Dimensions:
76 x 110 x 33 mm, antenna 35 mm
Can be operated according to
ERC REC 70-03
This product complies with ETSI EN 300220, ETS 300683, and EN 60950
Jablotron Ltd. hereby declares that the UC-82
is in compliance with the
essential requirements and other relevant provisions of Directive
1999/5/EC
The original of the conformity assessment can be found at
www.jablotron.com
, Technical Support section
Note:
Although this product does not contain any harmful materials we
suggest you return the product to the dealer or directly to the producer after
use.