UC-261 wireless indoor siren 

2 / 2 

MFI52702

 

 

7. 

A remote control or doorbell button 

(RC-4x, RC-22, 

RC-28) can be enrolled by pressing the button on the 
controller. Multiple pressing of the controller’s button will 
allow you to scroll to the desired melody. 

8. 

Detector-chime

 

mode: 

JA-60 detectors can be enrolled 

by inserting batteries into them, one detector at a time. By 
triggering the tamper on a detector you can scroll to the 
desired melody. 

9. 

Exit programming mode

 by briefly pressing the button 

on the UC-261.  

Note:

  

Up to 8 doorbell buttons or detectors can be used with one 
UC-261. 

If you enter programming mode the above way, all 
previously enrolled devices will be erased from the  
UC-261 memory. 

 

Enrolling additional devices  

 

If you want to add additional doorbell buttons or detectors, or 

if you want to select another melody for an existing device, then:  

1. Unplug the UC-261 from the outlet 

and wait for 5 seconds. 

2. Plug it in again.

 

3. When the button lights – press it and hold it down. After 

hearing a short beep, release the button. 

The flashing 

button indicates that it is in programming mode. 

4. Enrolling  new  devices 

(or selecting another melody): 

 

A doorbell button or remote control 

(RC-4x, RC-22, 

RC-28) can be enrolled by pressing the button on the 
controller. Multiple pressing of the controller’s button will 
allow you to scroll to the desired melody. 

 

Detector-chime

 

mode: 

JA-60 detectors can be enrolled 

by inserting batteries into them, one detector at a time. By 
triggering the tamper on a detector you can scroll to the 
desired melody.

 

5. Exit programming mode

 by briefly pressing the button on 

the UC-261. 

 

 

Deleting enrolled devices 

 

Press and hold the button on the UC-261 and plug the  

UC-261 into the mains outlet. Two beeps will be heard and all 
devices 

including the control panel 

will then be erased.  

Consequently it is necessary to erase the UC-261 from the 

control panel. In control panel enrollment mode scroll to the 
UC-261 position, press and hold button 2 until the confirmation 
beep can be heard.  

 

Note: If the memory of the UC-261 is deleted but the UC-261 is 
not erased from the control panel, then the control panel will 
indicate disconnection of the UC-261 from the power but 

the 

UC-261 will not react to signals from the control panel – in 
the case of an alarm it will not sound. 

 

Loudness selection 

 

 The UC-261 must be in its normal operating mode 

(plugged in). 

  Press and hold the button down. 

 After 2 seconds you will hear a melody with the new 

loudness selected 

  Release the button. 

 

This way you can toggle between a standard and a quieter 
level. This setting does not affect the alarm siren sound. 

 

Power failure 

 

If the UC-261 is disconnected from its power (it is 

unplugged or there is a power failure), then a “Low battery” 
report will be transmitted to the control panel. In addition if the 
system is in alarm mode (the sirens are sounding) the UC-261 
will also transmit a “TAMPER“signal.  

 

Doorbell-mode 

 

After pressing a doorbell button, the UC-261 will play a 

preselected melody.  Different melodies can be assigned to 
each doorbell button, if desired. If you want to change a 
melody, enter programming mode (see section “Enrolling 
Additional Devices”) and press the button until the desired 
melody is selected. 

 

Detector-chime mode

 

 

If an enrolled detector is triggered, the UC-261 will play a 

pre-selected melody. The melody can be changed if desired 
(see section “Enrolling Additional Devices”).   

A detector enrolled to the UC-261 can be simultaneously 

enrolled to a JA-63 or JA-65 control panel. This way, for 
example, a wireless door detector can activate a chime on the 
UC-261 and at the same time trigger an alarm.  

 

Notes:  

1/ The JA-60P motion detector has a special sleep mode 

feature (settable to 5 min. or 1 min.). Therefore it cannot detect 
more frequent movements in a covered area.  

2/ The JA-60SP, JA-60SR fire detectors and JA-60G 

cannot be used for chime mode. 

 

 

Wireless siren mode 

 

The UC-261’s light indicator shows the status of the PgY 

output of the enrolled control panel. If an alarm is triggered, the 
UC-261 siren sounds. ARM and DISARM chirps can be 
enabled or disabled by the following procedure: 

1.  Unplug the UC-261 from the outlet 

and wait for 

5 seconds. 

2.  Plug it in again.

 

3.  When the button lights – press it and hold it down. 

After hearing a short beep, release the button. 

The 

flashing button indicates that it is in programming mode. 

4.   On the control panel in P mode enter 299 repeatedly to 

toggle between these two settings: 

 

 When 

one

 beep is heard, no chirps will be performed by 

the UC-261. 

 When 

two

 beeps are heard, both ARM and DISARM 

chirps will be performed by the UC-261. 

 

   Note:

 Although this product does not contain any 

harmful materials we suggest you return the product to 
the dealer or directly to the producer after use. 

 

 

Internet: www.jab lotron.c z