background image

UC-260 Wireless Acoustic Indicator 

1 / 2 

MFI51304 

The UC-260 Wireless Acoustic Indicator

 

 

The UC-260 can be used as a wireless indoor siren, a melody 

doorbell or as a chime. It can also function as a small house alarm. The 
UC-260 is compatible with Jablotron wireless control panels (JA-63 and 
JA-65), JA-60 wireless detectors and RC-40, RC-22 and RC-28 remote 
controls. Several triggering devices can be used simultaneously and 
different melodies can be assigned to each device. Two different sound 
levels can be selected. The UC-260 provides entrance and exit delay 
chirps too, when used with a control panel.  

 

Specification 

 

Power supply 

230 V, 50 Hz 

Power consumption 

1.5 W 

Acoustics 

8 melodies and/or 110 dB/m alarm siren 

Input wireless devices  

max. 8 remote controls or detectors 

 

1 control panel, JA-63 or JA-65 

Class 

II according to EN60950 

Working frequency 

433.92 MHz 

Environmental conditions 

indoors –10 to +40°C 

Safety standards 

IP40 according to EN 60529, IEC 529 

 

Hereby, Jablotron Ltd., declares that this UC-260 complies with the 
essential requirements and other relevant provisions of Directive 
1999/5/EC.

 

Original conformity assessment can be found at the web 

page www.jablotron.cz, section Technical support. 

 

 

Installation 

 

The UC-260 is powered directly from a power outlet. The device 

should not be installed close to any metal structures or other objects 
obstructing radio signal transmissions.  

 

Enrolling wireless devices

 

 

1. Press and hold the button on the top of the UC-260. 

2. Plug the UC-260 into an outlet 

and hold the button until you hear 2 

beeps.  

3. Release the button 

– The button will begin to flash, indicating it is in 

programming mode. 

4. Enrolling the desired devices: 

 

A remote control or doorbell button 

(RC-40, RC-22, RC-28) 

can be enrolled by pressing the button on the controller. Multiple 
pressing of the controller’s button will allow you to scroll to the 
desired melody. 

 

Detector-chime

 

mode: 

JA-60 detectors can be enrolled by 

inserting batteries into a detector. If you remove the batteries and 
insert them again you can scroll to the desired melody (wait for 10 
seconds before reinsertion). 

 

 

 

Control panel – siren mode

 (JA-63 or JA-65) - enter the code 

299 on the control panel unit while in service mode. 

5. 

Up to 8 doorbell buttons or detectors can be used with one UC-260. 

6. 

Exit programming mode

 by briefly pressing the UC-260 

button. 

 

 

 

If you enter programming mode the above way, all previously enrolled 
devices will be erased from memory. 
  

 

Enrolling additional devices  

 

If you want to add additional doorbell buttons or detectors, or if you 

want to select another melody for an existing device, then:  

1. Unplug the UC-260 from the outlet 

and wait for 5 seconds. 

2. Plug it in again.

 

3. When the button will light – press it and hold it down. After 

hearing a short beep, release the button.  

The flashing button 

indicates that it is in programming mode. 

4. Enrolling new devices 

(or selecting another melody): 

 

A doorbell button or remote control 

(RC-40, RC-22, RC-28) 

can be enrolled by pressing the button on the controller. Multiple 
pressing of the controller’s button will allow you to scroll to the 
desired melody. 

 

Detector-chime

 

mode: 

JA-60 detectors can be enrolled by 

inserting batteries into a detector. If you remove the batteries and 
insert them again you can then scroll to the desired melody (wait 
for 10 seconds before reinsertion).

 

 

Control panel – siren mode

 (JA-63 or JA-65) – while in the 

service mode of the control panel, enter the code 299. Up to 8 
doorbell buttons or detectors can be used with one UC-260. 

 

5. Exit programming mode

 by briefly pressing the UC-260 button.

 

 

 

Deleting enrolled devices 

 

Press and hold the button on the UC-260 and plug the UC-260 into the 

mains outlet. Two beeps will be heard and all devices will then be erased.  

 

Loudness selection 

 

  The UC-260 must be in its normal operating mode (plugged in). 

  Press and hold the button down. 

  After 2 seconds you will hear a melody with the new loudness 

selected 

  Release the button. 

 

This way you can toggle between a standard and a quieter level. 
This setting does not affect the alarm siren sound. 

 