The OS-360/365 outdoor siren
2
MGZ 51203
Finishing installation
The following conditions are necessary for the OS-360/365 to be
ready:
1.
SIR
terminal connected to GND
2.
FLA
terminal connected to GND
3. Connected and charged
NiCd battery
(voltage higher than 4 V)
4. Power supply connected to the
+12 V
and
GND
terminals
The siren will flash once after 2 seconds and if the battery is charged
enough the siren will shortly sound in 45 seconds to confirm
operational readiness. If the battery is discharged the start-up cycle is
repeated until the battery is charged enough. This will be confirmed by
a short siren sound.
Functions:
Power supply failure
will cause the activation of both the siren and
flasher. When the power supply is restored siren, sounding and flashing
will be terminated in 3 seconds. If the power supply is permanently
disconnected, the siren will be switched off automatically in 5 minutes.
Disconnecting SIR from GND -
will cause the siren to be activated
(but without flasher activation). If SIR is connected back to GND the
siren sounding will be terminated immediately. Otherwise the siren will
be automatically deactivated in 5 minutes.
Disconnection of FLA from GND -
will cause the flasher to be
activated (but without siren activation). If FLA is connected back to
GND, flashing will be terminated immediately or in 60 minutes
depending on the settings (this time can be shortened by any change
in the ARM input). There is no limit on flasher activation – flashing will
continue until the FLA input is connected to GND.
Change of ARM input –
if the CHIRP jumper is in the ON position,
then on connection of ARM to GND the siren will make one chirp and
the flasher will flash briefly. On disconnection from GND the siren will
make two chirps and the flasher will flash twice.
If the flasher is flashing due to FLA activation, then any change in the
ARM input (connection or disconnection from GND) will terminate the
flashing. (The FLA terminal must be deactivated – connected to GND).
Stand-by –
if the SIR and FLA inputs are connected to GND, there is a
proper power supply, the backup battery is charged and the OK jumper
is in position ON, then the siren will flash once every 45 seconds.
Example of use
JA-63K(R)
2k2
L4 set to tamper
PGY set to ARM
(see also the control panel manual)
CHIRP
FLASH
OK
ON
ON
OFF
measurements points
- see Table 1
(if remote measurement is not needed, then it is possible to
connect the SIR and FLA terminals to GND
n the siren
directly i
Picture 2 example of connection to the JA-63K(R) control panel
In this configuration the siren and the flasher are activated during an alarm
from the control panel. Arming and disarming are confirmed by chirps.
Flashing is terminated immediately after disarming the control panel
regardless of the setting of the FLASH jumper. The battery voltage can be
measured at the measurement points shown – see Table 1.
measurement points
- see Table 1
JA-65K
2k2
CHIRP
FLASH
OK
OFF
ON
ON
Picture 3 – example of connection to the JA-–65Kcontrol panel
In this configuration, the siren sounds for the duration of the alarm.
Additionally the flasher flashes for another 60 minutes. Flashing can be
terminated by arming or disarming. The chirps are disabled and the flasher
will flash once every 45 seconds to confirm operational readiness of the
siren. The battery voltage can be measured at the measurement points
shown– see Table 1.
Maintenance
The siren does not need any special maintenance. The lifetime of the
NiCd battery is about 3 years, depending on the working conditions. If
the power supply (+12V and GND) is cut off for longer period of time,
then also disconnect the battery. The battery can be checked remotely
(see Table 1).
Note:
In order not to activate the siren before disconnecting the power
supply, first disconnect the battery.
Warning! If the siren is activated when the siren
connector (see picture 1) is being disconnected, the
siren will not be damaged, but there will be high
voltage on the terminal.
Note:
There is NiCd battery containing Cd (cadmium)
Although this product does not contain any harmful
materials we suggest you to return the product to the
dealer or directly to the producer after usage.
Internet: www.jablotron.com
tel.: 483 559 999
fax: 483 559 993
Pod Skalkou 33
466 01 Jablonec nad Nisou