background image

The OS-360/365 outdoor siren 

2

 

MGZ 51203

 

Finishing installation 

 

The following conditions are necessary for the OS-360/365 to be 

ready: 

 

1. 

SIR

 terminal connected to GND 

2. 

FLA

 terminal connected to GND 

3.  Connected and charged 

NiCd battery 

(voltage higher than 4 V) 

4.  Power supply connected to the 

+12 V

 and 

GND 

terminals 

 

The siren will flash once after 2 seconds and if the battery is charged 

enough the siren will shortly sound in 45 seconds to confirm 

operational readiness. If the battery is discharged the start-up cycle is 

repeated until the battery is charged enough. This will be confirmed by 

a short siren sound. 

 

Functions: 

 

Power supply failure

  will cause the activation of both  the siren and 

flasher. When the power supply is restored siren, sounding and flashing 

will be terminated in 3 seconds. If the power supply is permanently 

disconnected, the siren will be switched off automatically in 5 minutes.  

 

Disconnecting SIR from GND  - 

will cause the siren to be activated 

(but without flasher activation). If SIR is connected back to GND the 

siren sounding will be terminated immediately. Otherwise the siren will 

be automatically deactivated in 5 minutes. 

 

Disconnection of FLA from GND - 

will cause the flasher to be 

activated (but without siren activation). If FLA is connected back to 

GND, flashing will be terminated immediately or in 60 minutes 

depending on the settings (this time can be shortened by any change 

in the ARM input). There is no limit on flasher activation – flashing will 

continue until the FLA input is connected to GND. 

 

Change of ARM input – 

if the CHIRP jumper is in the ON position, 

then on connection of ARM to GND the siren will make one chirp and 

the flasher will flash briefly. On disconnection from GND the siren will 

make two chirps and the flasher will flash twice.  

If the flasher is flashing due to FLA activation, then any change in the 

ARM input (connection or disconnection from GND) will terminate the 

flashing. (The FLA terminal must be deactivated – connected to GND). 

 

Stand-by – 

if the SIR and FLA inputs are connected to GND, there is a 

proper power supply, the backup battery is charged and the OK jumper 

is in position ON, then the siren will flash once every 45 seconds.  

Example of use 

 

JA-63K(R)

2k2

L4 set to tamper

PGY set to  ARM

(see also the control panel manual)

CHIRP  

FLASH 

OK        

ON

ON

OFF

measurements points 

- see Table 1 

  (if remote measurement is not needed, then it is possible to 

  connect the SIR and FLA terminals to GND 

n the siren

directly i

 

Picture 2 example of connection to the JA-63K(R) control panel

 

In this configuration the siren and the flasher are activated during an alarm 

from the control panel. Arming and disarming are confirmed by chirps. 

Flashing is terminated immediately after disarming the control panel 

regardless of the setting of the FLASH jumper. The battery voltage can be 

measured at the measurement points shown – see Table 1. 

 

 

 

 

measurement points 

- see Table 1 

JA-65K

2k2

CHIRP  

FLASH 

OK        

OFF

ON

ON

 

Picture 3 – example of connection to the JA-–65Kcontrol panel

 

 

In this configuration, the siren sounds for the duration of the alarm. 

Additionally the flasher flashes for another 60 minutes. Flashing can be 

terminated by arming or disarming. The chirps are disabled and the flasher 

will flash once every 45 seconds to confirm operational readiness of the 

siren. The battery voltage can be measured at the measurement points 

shown– see Table 1. 

 

 

Maintenance 

 

The siren does not need any special maintenance. The lifetime of the 

NiCd battery is about 3 years, depending on the working conditions. If 

the power supply (+12V and GND) is cut off for longer period of time, 

then also disconnect the battery. The battery can be checked remotely 

(see Table 1). 

 

Note: 

In order not to activate the siren before disconnecting the power 

supply, first disconnect the battery.  

 

Warning! If the siren is activated when the siren 

connector (see picture 1) is being disconnected, the 

siren will not be damaged, but there will be high 

voltage on the terminal. 

 

 

 

Note:

  There is NiCd battery containing Cd (cadmium) 

Although this product does not contain any harmful 

materials we suggest you to return the product to the 

dealer or directly to the producer after usage.

 

 

Internet: www.jablotron.com

tel.:   483  559  999   

fax:  483 559 993

Pod Skalkou 33 

466 01 Jablonec nad Nisou

Reviews: